Page 49
Chapter 5 Programming Introduction to Label Programming The programming bar code labels contained in this manual will allow you to customize and configure features and settings for your scanner. To ensure full compatibility and proper function, use only the programming bar codes in this manual and other product-specific publications to program scanner features. This manual has been developed to make it quick and easy for users of all levels to find the information needed to understand and configure features. The following descriptions will help you to determine where to go from here.
Understanding the Basics If you have little or no prior experience with programming using bar code labels, you should review the first few pages of this section to familiarize yourself with the basics of scanner programming before performing any changes to your configuration.
Integrating the Scanner With Your Host System Your scanner MUST be equipped with the correct hardware (interface board, cable, etc.) to properly communicate with your host system. Contact your dealer for information if you have questions about your scanner’s hardware compatibility.
Product Reference Guide
5-1
Page 50
Programming
You may also want to contact the dealer or your system administrator if you have no record of how your scanner was pre-programmed at the factory. Scanners are typically programmed with the default settings for specific interface types (see Appendix E, Factory Defaults for more information); however, your scanner may have been custom configured with settings that are unique to your company or application. Once you know the scanner’s current settings, you can determine what changes will be required to allow communication with your host system and/or optional features you choose to modify to customize your installation. After recording the modifications needed, finish reading this section, then turn to the appropriate page and follow the instructions to program the scanner. When all scanner features are programmed to your satisfaction, the scanner is ready to be placed into operation.
Customizing Your Scanner’s Operation Most scanner programming falls within three general categories:
CAUTION
NOTE
5-2
•
General Scanner Features - are features common to all interface types. Examples include beeper adjustments such as volume and length, read verification settings, etc.
•
Interface Related Features - are the mandatory settings necessary to allow communication with your host terminal. Examples of these settings are: RS-232 baud rate and parity.
It is possible, via programming bar codes, to change the interface type (for example: from RS-232 to IBM Port 17). Great care should be taken to select the correct interface type, since you can cause damage to the scanner and/or POS terminal by attempting to change to an incompatible interface. ALWAYS make interface selections with the host cable DISCONNECTED. Ensure that your planned modifications are compatible with the current interface. For example, baud rate selections are only valid in the RS-232 interface. The scanner will sound an error tone when scanning programming labels for features invalid to the current interface group.
®
Magellan
2200VS and 2300HS
Page 51
Programming Overview
•
Symbology Programming - gives the scanner the capability to autodiscriminate as few as one, and as many as all available symbologies. For optimal scanner performance enable only those symbologies required. Additionally the scanner may be programmed with the standard options available for the various symbologies, such as check digit, minimum label length, fixed and variable length bar codes, etc.
If you experience difficulties, have questions or require additional information, contact your local distributor, or call your dealer or sales representative.
Programming Overview The scanner’s programmable feature settings can be modified to accommodate your system’s unique requirements. These settings can be communicated to the scanner in one of two ways: 1. Commands can be sent directly from the host. A limited set of host commands are available. Refer to Appendix D for more details or contact Tech Support. 2. Programming bar code labels can also be used to modify the scanner’s programmable settings. This manual provides the bar code labels and instructions necessary to configure the scanner’s features and options. When you program the scanner using any of the methods above, the scanner will store the changes until reprogrammed or returned to factory defaults. NOTE
Product Reference Guide
5-3
Page 52
Programming
Programming via Handheld Device The scanner can also accept programming via its auxiliary port using a handheld scanning device. Eligible handheld devices must have the ability to transmit Code 128 function codes such as the programming bar codes presented in this manual. Datalogic models QuickScan® 1000 and QuickScan® 6000 support this functionality. Handheld data format requirements (baud rate, parity, etc.) are presented in Appendix F of this manual. Additionally the programmable feature, Aux Port Mode, must be set to “External Handheld Input” to allow operation.
What Is Programming Mode? Programming Mode is a state in which the scanner must be placed in order to accept commands via programming bar code labels. When programming using the bar code labels in this manual, the scanner is typically placed in Programming Mode by scanning the SWITCH label. While in the Programming Mode, the scanner only recognizes the special programming bar codes contained in this programming guide. See Appendix A for information about scanner indications while in the Programming Mode.
Entering and Exiting Programming Mode. Use the bar code label below to enter and exit (‘switch” into and out of ) Programming Mode.
SWITCH LABEL
5-4
®
Magellan
2200VS and 2300HS
Page 53
Programming Overview
Programming Session A typical programming session is conducted as follows: 1. Scan the SWITCH bar code to place the scanner in Programming Mode. Depending upon its current programming, the scanner may emit a beep or beeps, indicating it has read the bar code and the green LED will flash on and off slowly while the scanner remains in Programming Mode. Normal scanning functions are disabled. 2. Scan the programming bar code(s) that is (are) specially encoded to make the desired changes. With few exceptions1, the scanner will emit a triple beep each time you scan a valid programming bar code. Not all features are available for all interfaces and the scanner will sound an error tone when scanning programming bar codes for features invalid to the current interface. Only features supported by the currently active interface will be implemented. NOTE If a bar code is scanned that changes the scanner’s interface, all previous configuration items scanned in the programming session are lost. NOTE
Additionally, when programming a feature requiring you to scan single digits to set a multi-digit number, such as Minimum Label Length, scanning the SWITCH bar code (or any item tag/item value bar code) before completing all input will result in an error tone and cause the scanner to exit Programming Mode. Under these circumstances, the current feature you were trying to set is thrown out; any previous bar codes scanned during the session will take effect.
1. Some features, such as Minimum Label Length, require you to select the label’s length by scanning a series of single-digit bar codes. A single ‘good read’ beep is sounded when scanning these single digits in Programming Mode. Only the final required digit in the sequence will produce a triple beep when scanned, indicating a successfully programmed feature.
Product Reference Guide
5-5
Page 54
Programming
NOTE
It is recommended that programming sessions be limited to one feature at a time. Should you make a mistake in the programming sequence, it can be difficult to discover where an error has been made if several features are programmed at once. Additionally, it can be confusing to determine which features may or may not have been successfully set following such a session.
3. Scan the SWITCH bar code to save any new settings and exit Programming Mode. The scanner will sound a beep and reset upon exiting Programming Mode, and the green LED will return to its usual state (on steady or off ).
The scanner will exit Programming Mode under the following conditions:, the programming sequence has been completed or the SWITCH bar code is scanned, five minutes have passed without scanning activity. Any data programmed during the current session will be ignored1, and the scanner will reset and revert to its condition previous to initiating the exited session., power is disconnected. Disconnecting power during Programming Mode, before scanning the SWITCH bar code, will cause all new settings to be ignored. On power-up, the scanner will return to previous settings. 4. Maintain a good record of all changes made to ensure that you know if the original factory settings have been changed.
1. Exception: If an interface bar code had been read while in Programming Mode, the scanner will operate on the default settings for the new interface.
5-6
®
Magellan
2200VS and 2300HS
Page 55
Programming Overview
Programming Sequence To modify a scanner feature (item), the programming bar codes contained in this manual must be scanned in a given sequence depending upon the feature being programmed (as shown in Table 5-1). There are three possible programming sequences:
NOTE
If the scanner’s interface type must be changed, always be sure that interface configuration is the FIRST item scanned during a programming session. (Changing an interface type resets ALL other configuration items to the factory default for that interface type.)
A. Programming sample A (the most commonly used format) demonstrates how three bar codes are scanned in sequence to do the following: 1. Place the scanner in Programming Mode (SWITCH bar code). 2. Scan the Item Tag1 that will enable the new feature. 3. End the programming session and reset the scanner (SWITCH bar code). B. Sample B provides an example of a programming feature requiring the entry of a range value. Like sample A, the scanner is placed in Programming Mode and an Item Tag1 is scanned. Then, a value must be entered before ending the programming session. In the example, three digits must be scanned from the number pad in Appendix C. This type of format, requiring several bar codes, is necessary to allow flexible programming for item values with larger numeric ranges. C. The programming sequence shown in example C requires scanning of a single, extended length bar code. This special programming bar code contains all the data necessary to enter Programming Mode, set the Item Tag1 and Item Value, and exit Programming Mode (all in one step).
1. An “Item Tag” is a term used to describe an assigned number, which is encoded in a programming bar code, that toggles (selects, enables, disables, etc.) a specific programming feature.
Product Reference Guide
5-7
Page 56
Programming
Table 5-1. Programming Sequence
A
SET
ITEM TAG
END/RESET
1
2
3
SWITCH
ENABLE NEW FEATURE
SWITCH
1
2
ITEM VALUE
345
6
0
B SWITCH
C
5-8
ENABLE NEW FEATURE USING THE FOLLOWING SETTINGS...
0
8
SWITCH
1 ONE BAR CODE CONTAINS SWITCH + ITEM TAG + ITEM VALUE + SWITCH
®
Magellan
2200VS and 2300HS
Page 57
LED and Beeper Indicators
LED and Beeper Indicators The scanner provides a set of indicators that verify/announce the various scanner functions.
If You Make a Mistake... If, during a programming session, you find that you are unsure of the scanner’s settings or wish to reset the scanner’s configuration, use the Return to Factory Settings label below to return the scanner’s configuration to the factory settings. Scanning this label will also reset any changes made during previous programming sessions.
Return to Factory Settings Scan this bar code to return the scanner to the default settings configured at the factory. This bar code is typically used to return the scanner to a “known” operating state when the present programming status is not known, faulty, or suspect. The process of Returning to Factory Settings requires two steps: 1. Scan the Return to Factory Settings bar code. 2. Set your required interface type using the instructions in Interface Related Features on page 5-37. Step 2 is important because the Return to Factory Setting bar code may alos change your scanner’s interface type.
Use this bar code with caution, since it will reset ALL features that may have been programmed since the scanner’s installation. CAUTION
DO NOT scan the SWITCH bar code before and after scanning this bar code. NOTE
Product Reference Guide
5-9
Page 58
Programming
RETURN TO FACTORY SETTINGS
Test Mode Use this feature to place the scanner into a testing, or “demo” mode. This special mode disables the scanner interface, meaning that bar code data is not sent out to the host via the scanner interface. This allows the bar code to be scanned continuously without requiring a response from the POS terminal. To return the scanner to normal function, scan the TEST MODE = DISABLE bar code below. DO NOT scan the SWITCH bar code before and after scanning the bar codes on this page. NOTE
Scanning the TEST MODE = DISABLE bar code sets the Double Read Timeout to 600ms.
TEST MODE = DISABLE
TEST MODE = ENABLE
5-10
®
Magellan
2200VS and 2300HS