Page 41
Chapter 4 Problem Isolation In the event of a suspected functional problem, use the troubleshooting references provided in this section. This useful information will help you identify and resolve the cause of the problem. The scanner incorporates features that indicate when a problem occurs. The scanner may: • emit a series of tones
• flash the LED (lamp)
Three error reporting modes are used: Power-Up Selftest, Operational tests and Diagnostic tests. These test sequences are explained on the following pages.
Power-Up Selftest The Power-up Selftest is a pre-operational series of tests that must be successfully completed before the scanner indicates readiness for operation. This pre-operational period is the time between power-up and normal operation during which the motor comes up-to-speed and software, firmware and hardware are being tested. These tests ensure that all subsystems are fully functional before turning on the Visible Laser Diode (VLD). Refer to Chapter 3, Operational Modes, for a more detailed description of this and other scanner modes.
Operational Tests These are the tests that run continually during Normal Operation and Sleep Mode. Firmware checks all subsystems, accessory connections as well as the POS interface to verify everything is operating normally. If a problem is detected at any time, a long, low tone is sounded and operation may be halted. If you press the Volume/Tone Push Button at that time, a series of tones will be sounded in concert with LED flashes.
Product Reference Guide
4-1
Page 42
Problem Isolation
Diagnostic Tests See Chapter 3, Scanner Diagnostic Mode for details about running diagnostic tests for the scanner. If a problem is discovered during diagnostics, the scanner will provide feedback about the source of the problem. The remainder of this section describes these failure indications and includes troubleshooting flowcharts to help isolate the problem.
Diagnostic Procedures Your Point-Of-Sale (POS) system may contain many components that operate as a system. Since almost all scanner problems are caused by either the scanner, POS terminal or communication links between them, troubleshooting flowcharts provided in this chapter focus on these components. Additionally, the AC/DC Power Supply and scanner cables are potential problems addressed. The flowcharts provided here walk you through a diagnostic process that will isolate the failed component and instruct as to the corrective action required. Since internal scanner components cannot be replaced by an operator or installer, most functional errors will require the assistance of a trained technical support person. However, if the problem is caused by faulty cable, or power supply, you can fix the problem by replacing the defective component and complete the installation.
4-2
®
Magellan
2200VS and 2300HS
Page 43
Error Codes
Error Codes If an error is detected, the scanner will sound a long low tone (for three seconds) and flash its LED, indicating a failure. When this occurs, press the Volume/Tone Push button to hear the error code. If it is configured to do so, the scanner will sound a series of beeps corresponding to the error code and/or flash its LED simultaneous to the beeps. The table below describes what these codes mean and what action should be taken for each.
When troubleshooting, always remember to check all cable connections first before proceeding with other problem isolation steps.
Error Beep
Probable Cause
Corrective Action
Configuration
No POS interface has been selected (Null interface). See Chapter 5, Interface Type to select the required interface using programming bar codes.
1
Configuration Error
See Chapter 5 for details about configuring the scanner using programming bar codes.
2
Interface Board
3
Motor
4
Laser
6
Digital Board
10
Button Module
Beeper “Chirp”
Product Reference Guide
Unplug unit and call technical support personnel.
4-3
Page 44
Problem Isolation
Flowcharts The problem isolation flowcharts on the following pages allow you to identify and troubleshoot problems with your system. Figure 4-1. Problem Isolation: Start
For units using an AC/DC adapter, verify that... 1. AC Adapter is connected to a functional AC outlet. 2. Power cord is firmly connected to scanner. If your unit is a model which receives Power Off the Terminal POT), verify that the I/F cable is securely connected at both ends.
START
Scanner
AC Adapter
Power-up Scanner power-up is signified by any or all of the following: - Facet wheel shows movement - Laser turns on - Status LED lights - Speaker sounds tone(s)
NO Does the scanner power-up ?
Flashing Green LED If the Green LED is flashing slowly, the scanner is most likely in Sleep Mode. Press and release the Volume/Tone Push Button or wave your hand in front of the vertical window to "wake-up" the scanner. A flashing Green LED can also mean the scanner has been disabled by the POS terminal. To exit this mode, cycle power or have the terminal re-enable the scanner.
NO
Have you checked the power connections ?
Check these potential problems: - AC/DC adaptor - AC outlet
YES
YES
Is the Green LED Lit ?
NO Ensure the Green LED is enabled via programming bar codes.
Is the Green LED Lit ?
YES Selftest Failure If the scanner fails its Selftest, the following takes place: - Speaker sounds a tone at the lowest value for approx. 3 seconds. - LED flashes on and off.
NO
YES
Call Tech Support Does the scanner pass Selftest ?
Consult the Selftest flowchart if you're unsure the unit has passed Selftest.
NO
Go to Selftest flowchart
NO
Go to Poor/No Reading flowchart
YES
Other Problems? Call Tech Support
4-4
YES
Will the scanner read bar codes reliably ?
®
Magellan
2200VS and 2300HS
Page 45
Flowcharts
Figure 4-2. Problem Isolation: Selftest
SELFTEST START
Is the LED blinking in error ?
Scan the Factory
NO
Is the error code 1 ?
YES Defaults bar code in Section 6 to enable the default configuration file. Restart the unit.
No interface selected (Null Interface). Select an interface.
Error Beeps ?
YES
NO
NO
YES
Is the error code 1 ?
YES
Call Tech Support
NO
Unit passes Selftest
Figure 4-3. Problem Isolation: Poor/No Reading
Product Reference Guide
4-5
Page 46
Problem Isolation
Have you verified that the scan window(s) is/are clean and scratch-free?
POOR/NO READING START Enter Scanner Diagnostic Mode by holding the Volume/Tone Push Button for 4 seconds (until first 3, and then 6 rapid tones are sounded) then release. Scan a known-good bar code. A good read is signified by one flash of the LED and a single beep1.
Does the scanner read the bar code satisfactorily ?
NO
Before proceeding, verify that bar code samples presented to scanner are of good quality and a symbology the scanner can read.
Call Tech Support
YES Reset the scanner by holding down the Volume/Tone Push Button for 8 seconds. If unexpected data is being sent from the host to the scanner, consider enabling the programmable feature Ignore Host Commands to debug the system.
Does the scanner pass the data to the POS ? NO Go to No Transmit to POS flowchart
YES
Does the scanner read satisfactorily ?
YES
DONE
NO Verify programmable parameters using the information and programming bar codes provided in Section 5. Check bar code symbology options and other configurable features.
Does the scanner read satisfactorily ?
YES
DONE
NO Troubleshoot the host or call Tech Support.
1 LED and beeper indications are configurable features. Behavior may vary from that described here.
4-6
®
Magellan
2200VS and 2300HS
Page 47
Flowcharts
Figure 4-4. Problem Isolation: No Transmit to POS
NO TRANSMIT TO POS START Check the interface (I/F) cable connections. If possible, retest the system using a knowngood I/F cable.
Does the scanner pass the data to the POS ? YES
NO
Verify programmable parameters using the information and programming bar codes provided in Section 5. Check interface and I/F options, inactive symbologies and other configurable features.
Does the scanner read satisfactorily ?
YES
DONE
NO Troubleshoot the host or call Tech Support.
DONE
This concludes the Problem Isolation Chapter.
Product Reference Guide
4-7