2-Digit Supplemental •
Supplemental data is appended to any EAN base label.
•
Prefix must be ASCII characters ']E1'.
• length of Supplemental data including prefix must be 5. Total required length is 21 for EAN-13 and 16 for EAN-8.
•
Examples: addon portion is highlighted data is underlined.
UPC-A 2-Digit addon
']E00060992011187]E112'
UPC-E 2-Digit addon
']E00000000998875]E112'
EAN-8 2-Digit addon
']E400210126]E112'
EAN-13 2-Digit addon
']E01101234567891]E112'
5-Digit Supplemental •
Supplemental data is appended to any EAN base label.
•
Prefix must be ASCII characters ']E2'.
•
Length of supplemental data including prefix must be 8. Total required length is 24 for EAN-13 and 19 for EAN-8.
•
Examples: addon portion is highlighted data is underlined.
UPC-A 5-Digit addon
']E00060992011187]E212345'
UPC-E 5-Digit addon
']E00000000998875]E212345'
EAN-8 5-Digit addon
']E400210126]E212345'
EAN-13 5-Digit addon
']E01101234567891]E212345'
Product Reference Guide
F-11
Page 380
Code 128 Supplemental •
Supplemental data is appended to any EAN base label.
•
Prefix must be ASCII characters ']C0'.
• length of Supplemental data including prefix is variable but must be at least 9.
•
Examples: addon portion is highlighted data is underlined.
UPC-A Code 128 addon
']E00060992011187]C081000009
51'
UPC-E Code 128 addon
'E00000000998875]C0810000095 1'
EAN-8 Code 128 addon
']E400210126]C08100000951'
EAN-13 Code 128 addon
']E01101234567891]C081000009 51'
Bookland •
The 'Bookland' / ISBN code will be formatted as a vendor specific AIM label.
•
Prefix must be ASCII characters ']X0'.
• length of label data including prefix is 13.
•
Examples: ']X01234567890'.
Code 39
F-12
•
Check character must be included in label data.
•
Label length including start, stop and check characters and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
Start and stop characters "*" must be included in label.
•
Prefix must be ASCII characters ']A0' or ']A1'.
•
Example: '*]A0Code 39.TEST*'. ®
Magellan
2200VS and 2300HS
Page 381
Codabar •
Check character must be included in label data.
•
Label length including check character and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
Prefix must be ASCII characters ']F0'.
•
Start stop character sets must meet the matching requirement set forth by the scanner configuration item Codabar Start Stop Character Match.
•
Start stop character sets s must be of the form ABCD/ABCD and must be included in the label.
•
Example: ']F0s$99.95s' (the lower case ‘s’ at each end of the example is a placeholder for the start stop character set).
MSI/Plessey •
Check character must be included in label data.
•
Label length including check character and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
Prefix must be ASCII characters ']M0'.
•
Example: ']M0144769254'.
Code 93 •
Prefix must be ASCII characters ']G0'.
•
Label length excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
Example : ']G0Code93-test'.
Product Reference Guide
F-13
Page 382
RSS-14 •
Prefix must be ASCII characters ']e0'.
•
Check character must be included in label.
•
Label length excluding prefix characters must be 14 characters.
•
Example: ']e001044123456789'.
RSS Expanded •
Prefix must be ASCII characters ']e0'.
•
Label length excluding prefix characters must be at least 1 character. Maximum length is the maximum label size supported by the scanner.
•
Example: ']e001900123456789083103001750'.
I 2 of 5
F-14
•
Check character must be included in label data.
•
Label length including check characters and excluding prefix characters must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
Prefix must be an ASCII character ']I1' (other prefixes specify different check character properties which are not supported).
•
Example: ']I10123456789'.
®
Magellan
2200VS and 2300HS
Page 383
Code 128 / EAN128 •
Prefix must be either ASCII characters ']C0', ']C1' or ']C2'.
•
Label length excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
If EAN-128 Symbology is Enabled and prefix is ']C1', label will be identified as an EAN128 otherwise it is identified as a Code 128.
•
A prefix of ']C0' designates that no function code is present in the 1st or 2nd character position.
•
A prefix of ']C2' designates that a function code 1 is present in the 2nd character.
•
Example : ']C0Code_128.Test'.
PDF417 •
Prefix must be an ASCII characters ']L0'.
•
Label length excluding prefix character cannot exceed 300 characters. In addition to this, label length excluding prefix character must meet requirements imposed by the main scanner’s fixed or variable label length control for this symbology type.
•
Example : ']L0pdf_test_label'.
Product Reference Guide
F-15
Page 384
NOTES
F-16
®
Magellan
2200VS and 2300HS
Page 385
NOTES
Product Reference Guide
F-17
Page 386
NOTES
F-18
®
Magellan
2200VS and 2300HS
Page 387
ASCII Character Set The table on this page shows a set of ASCII characters and their corresponding Hex Values. The Hex Values in this table are needed for setting symbology specific label identifiers, as well as enabling custom prefix and suffix characters. ASCII Char.
Hex No.
ASCII Char.
Hex No.
ASCII Char.
Hex No.
ASCII Char.
Hex No.
NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US
00 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0E 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1D 1E 1F
SP ! “ # $ % & ’ ( ) * + , . / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?
20 21 22 23 24 25 26 27 28 29 2A 2B 2C 2D 2E 2F 30 31 32 33 34 35 36 37 38 39 3A 3B 3C 3D 3E 3F
@ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^ _
40 41 42 43 44 45 46 47 48 49 4A 4B 4C 4D 4E 4F 50 51 52 53 54 55 56 57 58 59 5A 5B 5C 5D 5E 5F
‘ a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL
60 61 62 63 64 65 66 67 68 69 6A 6B 6C 6D 6E 6F 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 7F
Page 388
Australia
Japan
France and Benelux
Latin America
Germany
Singapore
India
Spain and Portugal
Italy
United Kingdom
Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com
Datalogic Scanning Sarl Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com
Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com
Datalogic Scanning, Inc Telephone: (305) 591-3222 latinamerica.scanning@datalogic.com
Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.com
Datalogic Scanning India Telephone: 91- 22 - 64504739 india.scanning@datalogic.com
Datalogic Scanning Singapore PTE LTD Telephone: (65) 6435-1311 singapore.scanning@datalogic.com
Datalogic Scanning Sarl Sucursal en España Telephone: 34 91 746 28 60 spain.scanning@datalogic.com
Datalogic Scanning SpA Telephone: [39] (0) 39/62903.1 italy.scanning@datalogic.com
Datalogic Scanning LTD Telephone: 44 (0) 1923 809500 uk.scanning@datalogic.com www.scanning.datalogic.com Datalogic Scanning, Inc. 959 Terry Street Eugene, OR 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140
©2002 - 2008 Datalogic Scanning, Inc.
R44-2715 (Rev. B)
12/08