Appendix F Handheld Data Format Requirements This appendix provides application notes to describe the general format of data that can be accepted by the scanner through the auxiliary port as transmitted from a handheld scanner.
Handheld Data Format Requirements General •
9600 bps, 8 data bits, 1 stop bit, no parity.
•
RTS is used to "bracket" the data received from the handheld: RTS must be asserted high during data transmission, and de-asserted after label transmission is complete. No other flow control mechanisms are required or supported.
•
Symbologies requiring fixed lengths (UPC/EAN) will enforce length requirements for validation of the label.
•
Handheld will be required to transmit start and stop characters for Codabar and Code 39 labels.
•
Appropriate industrial length requirements will be enforced (if configured) for validation of the label.
•
Maximum label lengths will be enforced for label validation (i.e. labels longer than the maximum label size will not be validated).
•
Standard Datalogic formats generally use a single prefix character. The specific formats are provided below.
Product Reference Guide
F-1
Page 370
Datalogic Handheld Data Format Requirements The following sections describe label transmission formats that are typically observed in factory configurations of Datalogic handheld scanners.
RSS-14 •
Prefix must be ASCII characters ‘R4’
•
Check character must be included in label
•
Application identifier “01” must follow the prefix and preceed the base label
•
Label length excluding prefix characters must be 16 characters.
•
Example: ‘R40101044123456789’
RSS Expanded •
Prefix must be ASCII characters ‘R4’
•
Check character must be included in label
UPC-A •
Number system must be included in label data.
•
Check digit must be included in label data and is assumed to be correct.
•
Prefix must be an ASCII character 'A' - total length including prefix must be 13.
•
Example: 'A060992011187'.
UPC-A with 2-Digit Supplemental
F-2
•
Number system must be included in label data.
•
Check digit must be included in label data and is assumed to be correct.
•
Supplemental data is appended to base label.
•
Prefix must be an ASCII character 'A' - total length including prefix must be 15.
•
Example: 'A06099201118712'. ®
Magellan
2200VS and 2300HS
Page 371
UPC-A with 5-Digit Supplemental •
Number system must be included in label data
•
Check digit must be included in label data and is assumed to be correct
•
Prefix must be an ASCII character 'A' - total length including prefix must be 18
•
Example: 'A06099201118712345'
UPC-A with Code 128 Supplemental •
Number system must be included in label data.
•
Check digit must be included in label data and is assumed to be correct.
•
Supplemental data is appended to base label.
•
Prefix must be an ASCII character 'A' - total length including prefix must be greater or equal to 19 Code 128 Supplemental codes are variable length having a minimum of 2 data characters).
•
Characters immediately following base label must be of the form '8100', '8101' or '8102'.
•
Example: 'A0609920111878100000951'.
UPC-E •
Number system must be included in label data
•
Check digit must be included in label data and is assumed to be correct
•
Prefix must be an ASCII character 'E' - total length including prefix must be 9
•
Example: 'E09988750'
Product Reference Guide
F-3
Page 372
UPC-E with 2-Digit Supplemental •
Number system must be included in label data.
•
Check digit must be included in label data and is assumed to be correct.
•
Supplemental data is appended to base label.
•
Prefix must be an ASCII character 'E' - total length including prefix must be 11.
•
Example: 'E0998875012'.
UPC-E with 5-Digit Supplemental •
Number system must be included in label data.
•
Check digit must be included in label data and is assumed to be correct.
•
Prefix must be an ASCII character 'E' - total length including prefix must be 14.
•
Example: 'E0998875012345'.
UPC-E with Code 128 Supplemental
F-4
•
Number system must be included in label data.
•
Check digit must be included in label data and is assumed to be correct.
•
Supplemental data is appended to base label.
•
Prefix must be an ASCII character 'E' - total length including prefix must be greater or equal to 15 (code 128 Supplemental codes are variable length having a minimum of 2 data characters).
•
Characters immediately following base label must be of the form '8100', '8101' or '8102'.
•
Example: 'E099887508101000951'.
®
Magellan
2200VS and 2300HS
Page 373
EAN-8 •
Check digit must be included in label data and is assumed to be correct
•
Prefix must be an ASCII characters 'FF' - total length including prefix must be 10
•
Example: 'FF00210126'
EAN-8 with 2-Digit Supplemental •
Check digit must be included in label data and is assumed to be correct.
•
Supplemental data is appended to base label.
•
Prefix must be an ASCII characters 'FF' - total length including prefix must be 12.
•
Example: 'FF0021012612'.
EAN-8 with 5-Digit Supplemental •
Check digit must be included in label data and is assumed to be correct.
•
Prefix must be an ASCII characters 'FF' - total length including prefix must be 15.
•
Example: 'FF0021012612345'.
EAN-8 with Code 128 Supplemental •
Check digit must be included in label data and is assumed to be correct.
•
Supplemental data is appended to base label.
•
Prefix must be an ASCII characters 'FF' - total length including prefix must be greater than 16 (code 128 Supplemental codes are variable length having a minimum of 2 data characters).
•
Characters immediately following base label must be of the form '8100', '8101' or '8102'.
•
Example: 'FF002101268102000951'.
Product Reference Guide
F-5
Page 374
EAN-13 •
Check digit must be included in label data and is assumed to be correct
•
Prefix must be an ASCII character 'F'- total length including prefix must be 14
•
Example: 'F1101234567891'
EAN-13 with 2-Digit Supplemental •
Check digit must be included in label data and is assumed to be correct
•
Supplemental data is appended to base label
•
Prefix must be an ASCII character 'F'- total length including prefix must be 16
•
Example: 'F110123456789112'
EAN-13 with 5-Digit Supplemental •
Check digit must be included in label data and is assumed to be correct.
•
Prefix must be an ASCII character 'F'- total length including prefix must be 19.
•
Example: 'F110123456789112345'.
EAN-13 with Code 128 Supplemental
F-6
•
Check digit must be included in label data and is assumed to be correct
•
Supplemental data is appended to base label
•
Prefix must be an ASCII character 'F'- total length including prefix must be greater or equal to 20 (code 128 Supplemental codes are variable length having a minimum of 2 data characters)
•
Characters immediately following base label must be of the form '8100', '8101' or '8102'
•
Example: 'F11012345678918100000951'
®
Magellan
2200VS and 2300HS
Page 375
Code 39 •
Check character must be included in label data.
•
Label length including start, stop and check characters and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
Start and stop characters "*" must be included in label.
•
Prefix must be an ASCII character '*'.
•
Example : '**Code 39.TEST*'.
Code 39-Pharmacode •
Check character must be included in label data.
•
Label length including start, stop and check characters and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
Start and stop characters "*" must be included in label.
•
Prefix must be an ASCII character 'p'.
•
Example: 'p*123456789*'.
I 2 of 5 •
Check character must be included in label data.
•
Label length including check characters and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
Prefix must be an ASCII character 'i'.
•
Example: 'i0123456789'.
Product Reference Guide
F-7
Page 376
Codabar •
Check character must be included in label data.
•
Label length including check character and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
Prefix must be an ASCII character '%'.
•
Start stop character sets must meet the matching requirement set forth by the scanner configuration item Codabar Start Stop Character Match.
•
Start stop character sets must be of the form ABCD/ABCD and must be included in the label.
•
Example: '%s$99.95s' (the lower case ‘s’ at each end of the example is a placeholder for the start stop character set).
Code 128
F-8
•
Prefix must be an ASCII character '#'.
•
Label length excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
Function characters may be transmitted as a hexadecimal value 8x. Where x correlates to function characters 1 thru 4 as follows:
• x80 = function code 1
• x81 = function code 2
• x82 = function code 3
• x83 = function code 4
•
For Code 128 programming labels the format is of the general form '#/82nnnnn/r ' - /82 is hexadecimal 82 and /r is carriage return.
•
Example: '#Code_128.Test'.
®
Magellan
2200VS and 2300HS
Page 377
MSI/Plessey •
Check character must be included in label data.
•
Label length including check character and excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
Prefix must be an ASCII character '@'.
•
Example: '@144769254'.
Code 93 •
Prefix must be an ASCII character '&'.
•
Label length excluding prefix character must meet requirements imposed by the main scanner's fixed or variable label length control for this symbology type.
•
Example: '&Code93-test'.
PDF417 •
Prefix must be an ASCII character 'P'.
•
Label length excluding prefix character cannot exceed 300 characters. In addition to this, label length excluding prefix character must meet requirements imposed by the main scanner’s fixed or variable label length control for this symbology type.
Product Reference Guide
F-9
Page 378
AIM Formats AIM specifies a 3-character string that is attached as a prefix to the label data for transmission. Because AIM specifies one identifier for UPC-A, UPC-E and EAN-13 labels, UPC-A, UPC-E and EAN-13 will be received from the handheld and transmitted by the scanner as EAN-13. The ']' character must be the first character received in the label transmission from the handheld. The following sections describe the prefix strings and identify what specific label characteristics can be supported.
UPC-A •
AIM does not specify UPC-A as a separate symbology using this transmission format - labels will be transmitted as EAN-13.
•
Example: ']E00060992011187'.
UPC-E •
AIM does not specify UPC-E as a separate symbology using this transmission format - labels will be transmitted as EAN-13.
•
Example: ']E00000000998875'.
EAN-13 •
Check digit must be included in label data and is assumed to be correct.
•
Prefix must be ASCII characters ']E0'- total length including prefix must be 16.
•
Example: ']E01101234567891'.
EAN-8
F-10
•
Check digit must be included in label data and is assumed to be correct.
•
Prefix must be ASCII characters ']E4' - total length including prefix must be 11.
•
Example: ']E400210126'.
®
Magellan
2200VS and 2300HS