The text of a manual · part 27 of 41
Magellan 2200VS and 2300HS Product Reference Guide: Programming, pages 259 to 268
Pages 259 to 268 of 388, from Magellan 2200VS and 2300HS Product Reference Guide
The original document is the PDF (6.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Datalogic M2360
Page 259
Code 128 Enable
Code 128 Transmit Function Characters Enables/disables transmission of Code 128 function characters 1, 2, 3, and 4.
Disabled is the recommended setting for all interfaces. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
CODE 128 TRANSMIT FUNCTION CHARACTERS = DISABLE
CODE 128 TRANSMIT FUNCTION CHARACTERS = ENABLE
Product Reference Guide
5-211
Page 260
Programming
Convert Code 128 to Code 39 Enables/disables conversion of Code 128 labels to Code 39. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
CONVERT CODE 128 TO CODE 39 = DISABLE
CONVERT CODE 128 TO CODE 39 = ENABLE
5-212
®
Magellan
2200VS and 2300HS
Page 261
Code 128 Enable
Code 128 AIM ID This feature enables/disables transmission of the Code 128 AIM symbology identifier. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
CODE 128 AIM ID = DISABLE
CODE 128 AIM ID = ENABLE
Product Reference Guide
5-213
Page 262
Programming
Code 128 Label ID This feature specifies a Code 128 label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF. 4. Complete the programming sequence by scanning the SWITCH bar code.
SET CODE 128 LABEL ID
5-214
®
Magellan
2200VS and 2300HS
Page 263
Code 128 Enable
Code 128 Length Control This feature specifies whether variable-length or fixed-length decoding will be set for Code 128. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.
NOTE
If variable-length control was selected, you must now set the features Code 128 Maximum Label Length and Code 128 Minimum Label Length. If fixed-length control was selected, you must now set Code 128 Fixed Length 1 and Code 128 Fixed Length 2.
CODE 128 LENGTH CONTROL = VARIABLE-LENGTH
CODE 128 LENGTH CONTROL = FIXED-LENGTH
Product Reference Guide
5-215
Page 264
Programming
Code 128 Maximum Label Length This feature specifies the maximum allowable length of a Code 128 label. Length in this case includes function characters and data characters, but does not include function code change or check character. This feature applies when Code 128 Length Control is set to variable-length decoding. NOTE
Maximum label length should be greater than or equal to minimum label length.
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 MAXIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired maximum label length. The selectable range for this option is 01 to 80. Pad all single digit numbers with a leading zero to yield a two-digit entry (01-80). 4. Complete the programming sequence by scanning the SWITCH bar code.
SET CODE 128 MAXIMUM LABEL LENGTH
5-216
®
Magellan
2200VS and 2300HS
Page 265
Code 128 Enable
Code 128 Minimum Label Length This feature specifies the minimum allowable length of a Code 128 label. Length in this case includes function characters and data characters, but does not include function code change or check character. This feature applies when Code 128 Length Control is set to variable-length decoding. NOTE
Minimum label length should be less than or equal to maximum label length.
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 MINIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired minimum label length. The selectable range for this option is 01 to 80. Pad all single digit numbers with a leading zero to yield a two-digit entry (01-80). 4. Complete the programming sequence by scanning the SWITCH bar code.
SET CODE 128 MINIMUM LABEL LENGTH
Product Reference Guide
5-217
Page 266
Programming
Code 128 Fixed Length 1 This feature specifies Code 128 first fixed length. This applies when Code 128 Length Control is set to fixedlength decoding. NOTE
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length. The selectable range for this option is 01 to 80. Pad all single digit numbers with a leading zero to yield a two-digit entry (01-80). 4. Complete the programming sequence by scanning the SWITCH bar code.
SET CODE 128 FIXED LENGTH 1
5-218
®
Magellan
2200VS and 2300HS
Page 267
Code 128 Enable
Code 128 Fixed Length 2 This feature specifies Code 128 second fixed length. This applies when Code 128 Length Control is set to fixedlength decoding. NOTE
If Fixed Length 2 is set to 00 (zero), then Fixed Length 1 will apply.
To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 128 FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length. The selectable range for this option is 01 to 80. Pad all single digit numbers with a leading zero to yield a two-digit entry (01-80). 4. Complete the programming sequence by scanning the SWITCH bar code.
SET CODE 128 FIXED LENGTH 2
Product Reference Guide
5-219
Page 268
Programming
Code 128 Stitching Enables/disables stitching for Code 128 labels. When parts of a Code 128 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.
CODE 128 STITCHING = DISABLE
CODE 128 STITCHING = ENABLE
5-220
®
Magellan
2200VS and 2300HS