Page 249

Code 39 Enable

Code 39 Maximum Label Length This feature specifies the maximum allowable length of a Code 39 label. Length in this case includes check, data and ASCII characters, but does not include start, or stop characters. This feature applies when Code 39 Length Control is set to variable-length decoding. NOTE

Maximum label length should be greater than or equal to minimum label length.

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 MAXIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired maximum label length. The selectable range for this option is 00 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (00-50). 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODE 39 MAXIMUM LABEL LENGTH Product Reference Guide

5-201

Page 250

Programming

Code 39 Minimum Label Length This feature specifies the minimum allowable length of a Code 39 label. Length in this case includes check, data and ASCII characters, but does not include start, or stop characters. This feature applies when Code 39 Length Control is set to variablelength decoding. NOTE

Minimum label length should be less than or equal to maximum label length.

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 MINIMUM LABEL LENGTH below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired minimum label length. The selectable range for this option is 00 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (00-50). 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODE 39 MINIMUM LABEL LENGTH

5-202

®

Magellan

2200VS and 2300HS

Page 251

Code 39 Enable

Code 39 Fixed Length 1 This feature specifies Code 39 first fixed length. This applies when Code 39 Length Control is set to fixed-length decoding. NOTE

The minimum decodable length is four when an optional check character is present.

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 FIXED LENGTH 1 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length. The selectable range for this option is 00 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (00-50). 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODE 39 FIXED LENGTH 1

Product Reference Guide

5-203

Page 252

Programming

Code 39 Fixed Length 2 This feature specifies Code 39 second fixed length. This applies when Code 39 Length Control is set to fixedlength decoding. NOTE

If Fixed Length 2 is set to 00, then Fixed Length 1 will apply

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET CODE 39 FIXED LENGTH 2 below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired fixed label length. The selectable range for this option is 00, no second fixed length, or 01 to 50. Pad all single digit numbers with a leading zero to yield a two-digit entry (00-50). 4. Complete the programming sequence by scanning the SWITCH bar code.

SET CODE 39 FIXED LENGTH 2

5-204

®

Magellan

2200VS and 2300HS

Page 253

Code 39 Enable

Code 39 Stitching Enables/disables stitching for Code 39 labels. When parts of a Code 39 bar code are presented to the scanner with this feature enabled, the bar code parts will be assembled by the scanner’s software, and the data will be decoded if all bar code proofing requirements are met. To set this feature: 1. Scan the SWITCH bar code. 2. Scan your selection from the bar codes below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. Complete the programming sequence by scanning the SWITCH bar code.

CODE 39 STITCHING = DISABLE

CODE 39 STITCHING = ENABLE

Product Reference Guide

5-205

Page 254

Programming

Pharmacode 39 Enable Enables/disables the ability of the scanner to decode Italian Pharmacode 39 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

PHARMACODE 39 = DISABLE

PHARMACODE 39 = ENABLE

5-206

®

Magellan

2200VS and 2300HS

Page 255

Pharmacode 39 Enable

Pharmacode 39 Start Stop Character Transmission Enables/ disables transmission of start and stop characters for Pharmacode 39. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE

To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

PHARMACODE 39 START STOP CHARACTER TRANSMISSION = DISABLE

PHARMACODE 39 START STOP CHARACTER TRANSMISSION = ENABLE

Product Reference Guide

5-207

Page 256

Programming

Pharmacode 39 Check Character Transmission Enables/disables transmission of Pharmacode 39 check character. This item is ignored when the advanced feature, Full Label Edit, is enabled. NOTE

To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

PHARMACODE 39 CHECK CHARACTER TRANSMISSION = DISABLE

PHARMACODE 39 CHECK CHARACTER TRANSMISSION = ENABLE

5-208

®

Magellan

2200VS and 2300HS

Page 257

Pharmacode 39 Enable

Pharmacode 39 Label ID This feature specifies a Pharmacode 39 label ID to be added to bar code data. The programming feature, RS-232 Label ID Control, designates whether the Label ID is transmitted as a prefix or suffix or if Label ID is disabled. NOTE

To set this feature: 1. Scan the SWITCH bar code. 2. Scan the bar code, SET PHARMACODE 39 LABEL ID below. You’ll need to cover any unused bar codes on this and the facing page to ensure the scanner reads only the bar code you intend to scan. 3. Scan the appropriate digits from the keypad in Appendix C that represent the desired Label ID characters; entered as two hex pairs. A table containing the ASCII Character Set and their corresponding Hex Values is available in the inside back cover of this manual. ASCII parameters must be input by scanning a pair of hexadecimal digits for each character. Thus, to set a two-character value of AB, bar codes containing the digits ‘4’, ‘1’, ‘4’, and ‘2’ must be scanned. The selectable range for this option is any hex value from 00 to FF. 4. Complete the programming sequence by scanning the SWITCH bar code.

SET PHARMACODE 39 LABEL ID

Product Reference Guide

5-209

Page 258

Programming

Code 128 Enable Enables/disables the ability of the scanner to decode Code 128 labels. To set this feature: 1. Scan the SWITCH bar code. 2. Scan either the enable or disable bar code below. You’ll need to cover any unused bar codes on this and the facing page to ensure that the scanner reads only the bar code you intend to scan. 3. Complete the programming sequence by scanning the SWITCH bar code.

CODE 128 = DISABLE

CODE 128 = ENABLE

5-210

®

Magellan

2200VS and 2300HS