The text of a manual · part 9 of 21
QuickScan Mobile Reference Manual: 3 CONFIGURATION, pages 65 to 74
Pages 65 to 74 of 176, from QuickScan Mobile Reference Manual
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic M2130
Page 65
Enter Configuration
Ì$+;Î
Exit and Save Configuration
Ì$-?Î
DATA FORMAT
FIELD ADJUSTMENT ‹ disable field adjustment
ÌEF0[Î Field adjustment allows a number of characters n, to be added to or subtracted from the barcode read. The adjustment can be different for each enabled code type. To define the field adjustment:
c Read the enable field adjustment code: enable field adjustment
ÌEF+Î d Select the code type from the Code Identifier Table in Appendix B. e Select the type of adjustment to perform: right addition
Ì01Î left addition
Ì12Î right deletion
Ì23Î left deletion
Ì34Î f Read a number in the range 01 - 32 from the Hex/Numeric Table to define how many characters to add or delete: Conditions: •
Adjustment is only performed on the barcode data; the Code Identifier and Code Length Transmission fields are not modified by the field adjustment parameter.
•
If the field setting would subtract more characters than exist in the barcode, the subtraction will take place only to code length 0.
•
You can set up to a maximum of 10 different field adjustments on the same barcode family or on different barcode families.
Example: To add 4 characters to the right of Standard Code 39 Codes: enable field adjustment
Read
ÌEF+Î
Code 39
+
ÌVWÎ right addition
+
Ì01Î
+
04
59
Page 66
Enter Configuration
Ì$+;Î
Exit and Save Configuration
DATA FORMAT
Ì$-?Î
FIELD ADJUSTMENT CHARACTER c Read the field adjustment character code: field adjustment character
ÌEG-Î d Read the hexadecimal value corresponding to the character you want to use for field adjustment. Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58. Example: To define the field adjustment character = A: field adjustment character
Read
+ 41
CODE LENGTH TX ‹ code length not transmitted
ÌEE0YÎ code length transmitted in variable-digit format
ÌEE1\Î code length transmitted in fixed 4-digit format
ÌEE2_Î The code length is transmitted in the message after the Headers and Code Identifier characters. The code length is calculated after performing any field adjustment operations.
60
Page 67
Enter Configuration
Ì$+;Î
Exit and Save Configuration
DATA FORMAT
Ì$-?Î
CHARACTER REPLACEMENT ‹ disable character replacement
ÌEO0mÎ This parameter allows up to three characters to be replaced from the barcode read. These substitutions are stored in memory. To define each character replacement:
c
Read one of the following character replacement codes: first character replacement
ÌEO1pÎ second character replacement
ÌEO2sÎ third character replacement
ÌEO3vÎ d
From the Code Identifier Table in Appendix B, read the Code Identifier for the desired code family. 0 = character replacement will be effective for all code families.
e
From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE) which identifies the character to be replaced. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58.
f
From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE) which identifies the new character to replace. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58. FF = the character to be replaced will be substituted with no character, that is, it will be removed from the code.
61
Page 68
Example: The following strings define: 1.
First Character Replacement: substitution in Code 39 barcodes of all occurrences of the 0 character with the 1 character.
2.
Second Character Replacement: substitution in Code 39 barcodes of all occurrences of the A character with the B character.
first character replacement
Code 39
ÌEO1pÎ + ÌVWÎ +
ASCII characters corresponding to the HEX value for character 0
30
ASCII characters corresponding to the HEX value for character 1
+
31
For Code 39 codes containing the string "0123", the contents transmitted will be "1123".
second character replacement
Code 39
ÌEO2sÎ + ÌVWÎ +
ASCII characters corresponding to the HEX value for character A
41
ASCII characters corresponding to the HEX value for character B
+
42
For Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD".
62
Page 69
Enter Configuration
Ì$+;Î
Exit and Save Configuration
DATA FORMAT
Ì$-?Î
ADDRESS STAMPING ‹ disable reader address stamping
ÌRU0ÊÎ enable reader address stamping
ÌRU1"Î See par. 4.4.3 for details.
ADDRESS DELIMITER ‹ disable reader address delimiter
ÌRV0!Î enable reader address delimiter and select characters
ÌRV1$Î Read 2 HEX characters in the range 00-FE.
See par. 4.4.4 for details.
63
Page 70
READING PARAMETERS ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
HAND-HELD OPERATION STAND OPERATION HARDWARE TRIGGER MODE TRIGGER-OFF TIMEOUT FLASH MODE READS PER CYCLE SAFETY TIME BEEPER INTENSITY BEEPER TONE BEEPER TYPE BEEPER LENGTH STAND RECOGNITION BEEP
~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
= Read the code and follow the procedure given ‹
3.
64
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of each page.
Page 71
Enter Configuration
Exit and Save Configuration
Ì$+;Î
READING PARAMETERS
Ì$-?Î
HAND-HELD OPERATION ‹ hardware trigger
ÌBK1eÎ software trigger
ÌBK0bÎ * always on
ÌBK3kÎ * not available for Mobile series readers automatic
ÌBK2hÎ hardware trigger ready
ÌBK4nÎ
STAND OPERATION ONLY Devices with Stand Recognition Beep hardware trigger
ÌBU3ÃÎ software trigger
ÌBU1yÎ * always on
ÌBU2|Î * not available for Mobile series readers
‹ automatic
ÌBU0vÎ
65
Page 72
Enter Configuration
Ì$+;Î
Exit and Save Configuration
READING PARAMETERS
Ì$-?Î
HARDWARE TRIGGER MODE ‹ trigger active level
ÌBA0NÎ trigger active pulse
ÌBA1QÎ See par. 4.5.1 for details
TRIGGER-OFF TIMEOUT trigger-off timeout
ÌBD$Î Read 2 numbers in the range 00-99: 00 = disables the trigger-off timeout 01-99 = corresponds to a max. 99-sec. delay after the trigger press to allow the reader to turn off automatically. ‹ trigger-off timeout disabled
See par. 4.5.2 for details.
66
Page 73
Enter Configuration
Ì$+;Î
Exit and Save Configuration
READING PARAMETERS
Ì$-?Î
FLASH MODE
"FLASH" ON duration
ÌBB0PÎ "FLASH" OFF duration
ÌBB1SÎ Read 2 numbers in the range 01-99: 01 to 99 = from .1 to 9.9 seconds. ‹ Flash-ON = 1 sec. Flash-OFF = 0.6 sec
READS PER CYCLE
‹ one read per cycle
ÌBC0RÎ multiple reads per cycle
ÌBC1UÎ See par. 4.5.3 for details.
67
Page 74
Enter Configuration
Ì$+;Î
Exit and Save Configuration
READING PARAMETERS
Ì$-?Î
SAFETY TIME safety time
ÌBE&Î Limits same code consecutive reading.
Read 2 numbers in the range 00-99: 00 = no same code consecutive reading until reader is removed (no decoding) for at least 400 ms. 01-99 = timeout from .1 to 9.9 seconds before a consecutive read on same code. ‹ safety time = 0.5 sec
See par. 4.5.4 for details.
BEEPER INTENSITY * very low intensity
ÌBG0ZÎ low intensity
ÌBG1]Î medium intensity
ÌBG2`Î ‹ high intensity
ÌBG3cÎ *
68
This sets the beeper OFF for data entry, while for all other beeper signals it has the meaning “very low intensity”. The Beeper Intensity parameter is effective for all operating conditions described in par. 5.2.