Page 65

Enter Configuration

Ì$+;Î

Exit and Save Configuration

Ì$-?Î

DATA FORMAT

FIELD ADJUSTMENT ‹ disable field adjustment

ÌEF0[Î Field adjustment allows a number of characters n, to be added to or subtracted from the barcode read. The adjustment can be different for each enabled code type. To define the field adjustment:

c Read the enable field adjustment code: enable field adjustment

ÌEF+Î d Select the code type from the Code Identifier Table in Appendix B. e Select the type of adjustment to perform: right addition

Ì01Î left addition

Ì12Î right deletion

Ì23Î left deletion

Ì34Î f Read a number in the range 01 - 32 from the Hex/Numeric Table to define how many characters to add or delete: Conditions: •

Adjustment is only performed on the barcode data; the Code Identifier and Code Length Transmission fields are not modified by the field adjustment parameter.

•

If the field setting would subtract more characters than exist in the barcode, the subtraction will take place only to code length 0.

•

You can set up to a maximum of 10 different field adjustments on the same barcode family or on different barcode families.

Example: To add 4 characters to the right of Standard Code 39 Codes: enable field adjustment

Read

ÌEF+Î

Code 39

+

ÌVWÎ right addition

+

Ì01Î

+

04

59

Page 66

Enter Configuration

Ì$+;Î

Exit and Save Configuration

DATA FORMAT

Ì$-?Î

FIELD ADJUSTMENT CHARACTER c Read the field adjustment character code: field adjustment character

ÌEG-Î d Read the hexadecimal value corresponding to the character you want to use for field adjustment. Valid characters are in the range 00-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58. Example: To define the field adjustment character = A: field adjustment character

Read

+ 41

CODE LENGTH TX ‹ code length not transmitted

ÌEE0YÎ code length transmitted in variable-digit format

ÌEE1\Î code length transmitted in fixed 4-digit format

ÌEE2_Î The code length is transmitted in the message after the Headers and Code Identifier characters. The code length is calculated after performing any field adjustment operations.

60

Page 67

Enter Configuration

Ì$+;Î

Exit and Save Configuration

DATA FORMAT

Ì$-?Î

CHARACTER REPLACEMENT ‹ disable character replacement

ÌEO0mÎ This parameter allows up to three characters to be replaced from the barcode read. These substitutions are stored in memory. To define each character replacement:

c

Read one of the following character replacement codes: first character replacement

ÌEO1pÎ second character replacement

ÌEO2sÎ third character replacement

ÌEO3vÎ d

From the Code Identifier Table in Appendix B, read the Code Identifier for the desired code family. 0 = character replacement will be effective for all code families.

e

From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE) which identifies the character to be replaced. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58.

f

From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE) which identifies the new character to replace. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58. FF = the character to be replaced will be substituted with no character, that is, it will be removed from the code.

61

Page 68

Example: The following strings define: 1.

First Character Replacement: substitution in Code 39 barcodes of all occurrences of the 0 character with the 1 character.

2.

Second Character Replacement: substitution in Code 39 barcodes of all occurrences of the A character with the B character.

first character replacement

Code 39

ÌEO1pÎ + ÌVWÎ +

ASCII characters corresponding to the HEX value for character 0

30

ASCII characters corresponding to the HEX value for character 1

+

31

For Code 39 codes containing the string "0123", the contents transmitted will be "1123".

second character replacement

Code 39

ÌEO2sÎ + ÌVWÎ +

ASCII characters corresponding to the HEX value for character A

41

ASCII characters corresponding to the HEX value for character B

+

42

For Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD".

62

Page 69

Enter Configuration

Ì$+;Î

Exit and Save Configuration

DATA FORMAT

Ì$-?Î

ADDRESS STAMPING ‹ disable reader address stamping

ÌRU0ÊÎ enable reader address stamping

ÌRU1"Î See par. 4.4.3 for details.

ADDRESS DELIMITER ‹ disable reader address delimiter

ÌRV0!Î enable reader address delimiter and select characters

ÌRV1$Î Read 2 HEX characters in the range 00-FE.

See par. 4.4.4 for details.

63

Page 70

READING PARAMETERS ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

HAND-HELD OPERATION STAND OPERATION HARDWARE TRIGGER MODE TRIGGER-OFF TIMEOUT FLASH MODE READS PER CYCLE SAFETY TIME BEEPER INTENSITY BEEPER TONE BEEPER TYPE BEEPER LENGTH STAND RECOGNITION BEEP

~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups.

= Read the code and follow the procedure given ‹

3.

64

= Default value

Read the Exit and Save Configuration code ONCE, available at the top of each page.

Page 71

Enter Configuration

Exit and Save Configuration

Ì$+;Î

READING PARAMETERS

Ì$-?Î

HAND-HELD OPERATION ‹ hardware trigger

ÌBK1eÎ software trigger

ÌBK0bÎ * always on

ÌBK3kÎ * not available for Mobile series readers automatic

ÌBK2hÎ hardware trigger ready

ÌBK4nÎ

STAND OPERATION ONLY Devices with Stand Recognition Beep hardware trigger

ÌBU3ÃÎ software trigger

ÌBU1yÎ * always on

ÌBU2|Î * not available for Mobile series readers

‹ automatic

ÌBU0vÎ

65

Page 72

Enter Configuration

Ì$+;Î

Exit and Save Configuration

READING PARAMETERS

Ì$-?Î

HARDWARE TRIGGER MODE ‹ trigger active level

ÌBA0NÎ trigger active pulse

ÌBA1QÎ See par. 4.5.1 for details

TRIGGER-OFF TIMEOUT trigger-off timeout

ÌBD$Î Read 2 numbers in the range 00-99: 00 = disables the trigger-off timeout 01-99 = corresponds to a max. 99-sec. delay after the trigger press to allow the reader to turn off automatically. ‹ trigger-off timeout disabled

See par. 4.5.2 for details.

66

Page 73

Enter Configuration

Ì$+;Î

Exit and Save Configuration

READING PARAMETERS

Ì$-?Î

FLASH MODE

"FLASH" ON duration

ÌBB0PÎ "FLASH" OFF duration

ÌBB1SÎ Read 2 numbers in the range 01-99: 01 to 99 = from .1 to 9.9 seconds. ‹ Flash-ON = 1 sec. Flash-OFF = 0.6 sec

READS PER CYCLE

‹ one read per cycle

ÌBC0RÎ multiple reads per cycle

ÌBC1UÎ See par. 4.5.3 for details.

67

Page 74

Enter Configuration

Ì$+;Î

Exit and Save Configuration

READING PARAMETERS

Ì$-?Î

SAFETY TIME safety time

ÌBE&Î Limits same code consecutive reading.

Read 2 numbers in the range 00-99: 00 = no same code consecutive reading until reader is removed (no decoding) for at least 400 ms. 01-99 = timeout from .1 to 9.9 seconds before a consecutive read on same code. ‹ safety time = 0.5 sec

See par. 4.5.4 for details.

BEEPER INTENSITY * very low intensity

ÌBG0ZÎ low intensity

ÌBG1]Î medium intensity

ÌBG2`Î ‹ high intensity

ÌBG3cÎ *

68

This sets the beeper OFF for data entry, while for all other beeper signals it has the meaning “very low intensity”. The Beeper Intensity parameter is effective for all operating conditions described in par. 5.2.