The text of a manual · part 10 of 21
QuickScan Mobile Reference Manual: 3 CONFIGURATION, pages 75 to 84
Pages 75 to 84 of 176, from QuickScan Mobile Reference Manual
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic M2130
Page 75
Enter Configuration
Ì$+;Î
Exit and Save Configuration
READING PARAMETERS
Ì$-?Î
BEEPER TONE tone 1
ÌBH0\Î ‹ tone 2
ÌBH1_Î tone 3
ÌBH2bÎ tone 4
ÌBH3eÎ BEEPER TYPE ‹ monotone
ÌBJ0`Î bitonal
ÌBJ1cÎ BEEPER LENGTH long
ÌBI0^Î ‹ short
ÌBI1aÎ 69
Page 76
Enter Configuration
Ì$+;Î
Exit and Save Configuration
READING PARAMETERS
Ì$-?Î
STAND RECOGNITION BEEP ONLY Devices with Stand Recognition disable
ÌBV0xÎ ‹ enable
ÌBV1{Î
70
Page 77
DECODING PARAMETERS ~ ~ ~ ~ ~
INK SPREAD OVERFLOW CONTROL INTERDIGIT CONTROL DECODING SAFETY PUZZLE SOLVER™
~ ~ ~ ~ ~
Before changing these parameter values read the descriptions in par. 4.6. CAUTION
1. 2. 3.
Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups. ‹ = Default value
Read the Exit and Save Configuration code ONCE, available at the top of each page.
71
Page 78
Enter Configuration
Ì$+;Î
Exit and Save Configuration
DECODING PARAMETERS
INK SPREAD disable
ÌAX0{Î
‹ enable
ÌAX1~Î See par. 4.6.1 for details.
OVERFLOW CONTROL disable
ÌAW1|Î
‹ enable
ÌAW0yÎ See par. 4.6.2 for details.
72
Ì$-?Î
Page 79
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
DECODING PARAMETERS
INTERDIGIT CONTROL disable
ÌAV0wÎ
‹ enable
ÌAV1zÎ See par. 4.6.3 for details.
DECODING SAFETY
‹ one read
ÌED0WÎ (decoding safety disabled) two reads
ÌED1ZÎ three reads
ÌED2]Î four reads
ÌED3`Î Required number of good reads before accepting code.
73
Page 80
Enter Configuration
Exit and Save Configuration
Ì$+;Î
DECODING PARAMETERS
Ì$-?Î
PUZZLE SOLVER™
‹ disable
ÌAU0uÎ enable
ÌAU1xÎ In the case of damaged or poorly printed codes, this parameter allows reading multiple parts of the single code to reconstruct it. To read codes using this technology, simply move the illuminated bar over the code so that each line of the code is scanned. During this process a series of brief “ticks” indicates that reading is proceeding correctly.
Conditions: •
This parameter is only valid for the following codes: EAN 8 without Add-on
EAN 13 without Add-on
Code 128
Code 39
•
For Code 39, Check digit control is forced.
•
PuzzleSolver™ is not valid for ISBT 128 code.
74
UPC A without Add-on
Page 81
CODE SELECTION ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
EAN/UPC FAMILY 2/5 FAMILY CODE 39 FAMILY CODE 128 FAMILY CODABAR FAMILY CODE 93 MSI PLESSEY TELEPEN DELTA IBM CODE 11 CODE 16K CODE 49 GS1 DATABAR™
~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups.
= Read the code and follow the procedure given ‹
3.
= Default value
Read the Exit and Save Configuration code ONCE, available at the top of each page.
75
Page 82
Enter Configuration
Exit and Save Configuration
Ì$+;Î
CODE SELECTION
Ì$-?Î
DISABLE ALL CODE FAMILIES
ÌAZ0ÃÎ
The reader allows up to 5 code selections. This does not limit the number of CODES enabled to 5, as it depends on the code family. NOTE
SINGLE SELECTIONS =
•
ONE combination code from the EAN family
•
ONE code from the 2/5 family
Example 5 code selections:
1. 2/5 Interleaved 2. 2/5 Industrial 3. Code 128 + EAN 128 4. Code 39 Full ASCII + Code 32 5. UPC A/UPC E
In this section all SINGLE code selections are underlined and in bold.
76
Page 83
Enter Configuration
Exit and Save Configuration
Ì$+;Î
CODE SELECTION
Ì$-?Î
EAN/UPC FAMILY disable the family
ÌAA0MÎ c Read the desired family code Note: Since the EAN/UPC without ADD ON code selection is enabled by default, to correctly enable another selection, first disable the family.
WITHOUT ADD ON
‹ EAN 8/EAN 13/UPC A/UPC E
ÌAA1PÎ EAN 8/EAN 13
ÌAA3VÎ UPC A/UPC E
ÌAA4YÎ
77
Page 84
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
CODE SELECTION WITH ADD ON 2 AND 5
EAN 8/EAN 13/UPC A/UPC E
ÌAA5\Î EAN 8/EAN 13
ÌAA6_Î UPC A/UPC E
ÌAA7bÎ WITH ADD ON 2 ONLY
EAN 8/EAN 13
ÌAAK7Î UPC A/UPC E
ÌAAM=Î WITH ADD ON 5 ONLY
EAN 8/EAN 13
ÌAAL:Î UPC A/UPC E
ÌAAN@Î
78