For the Datalogic M2130
Page 125
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
RADIO PARAMETERS
BEEPER CONTROL FOR RADIO RESPONSE ‹ normal
ÌBF0XÎ only good decode
ÌBF1[Î only good reception
ÌBF2^Î off
ÌBF3aÎ See par. 4.7.3 for details.
119
Page 126
Enter Configuration
Ì$+;Î
Exit and Save Configuration
RADIO PARAMETERS
Ì$-?Î
SINGLE STORE ‹ disable
ÌRO0zÎ one attempt
ÌRO1}Î two attempts
ÌRO2ÄÎ three attempts
ÌRO3ÇÎ four attempts
ÌRO4ÊÎ five attempts
ÌRO5"Î six attempts
ÌRO6%Î seven attempts
ÌRO7(Î eight attempts
ÌRO8+Î nine attempts
ÌRO9.Î See par. 4.7.4 for details
120
Page 127
Enter Configuration
Ì$+;Î
Exit and Save Configuration
RADIO PARAMETERS
Ì$-?Î
BATCH MODE ‹ disable batch
ÌBZ0ÄÎ enable normal batch
ÌBZ1ÇÎ enable automatic batch
ÌBZ2ÊÎ See par. 4.7.5 for details.
The following batch management parameters are complete commands and do not require reading the Enter and Exit configuration codes. start normal batch transmission
Ì#+BFlush]Î delete batch data
Ì#+BReset\Î
121