The text of a manual · part 14 of 21

QuickScan Mobile Reference Manual: 3 CONFIGURATION, pages 115 to 124

Pages 115 to 124 of 176, from QuickScan Mobile Reference Manual

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic M2130

Page 115

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

DEFINE FIELD 4 BY: EITHER field separator

ÌHG0`Î a)

Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator

Ì01Î

Ì12Î OR match character

ÌHG3iÎ b)

Read the match character from the HEX table. Range of characters = 01-FE. OR field length

ÌHG1cÎ c)

Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)

ÌHG2fÎ d)

AND Field 4 Terminators no field terminators

ÌHH0bÎ 1 field terminator

2 field terminators

ÌHH1eÎ

ÌHH2hÎ

Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58.

109

Page 116

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

DEFINE FIELD 5 BY: EITHER field separator

ÌHG0`Î a)

Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator

Ì01Î

Ì12Î OR match character

ÌHG3iÎ b)

Read the match character from the HEX table. Range of characters = 01-FE. OR field length

ÌHG1cÎ c)

Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)

ÌHG2fÎ d)

AND Field 5 Terminators no field terminators

ÌHH0bÎ 1 field terminator

2 field terminators

ÌHH1eÎ

ÌHH2hÎ

Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58.

110

Page 117

Exit and Save Configuration

ADVANCED FORMATTING

7

Ì$-?Î

First Additional Fixed Field no fixed field

ÌHI0dÎ 1 character fixed field

ÌHI1gÎ 2 character fixed field

ÌHI2jÎ 3 character fixed field

ÌHI3mÎ 4 character fixed field

ÌHI4pÎ 5 character fixed field

ÌHI5sÎ 6 character fixed field

ÌHI6vÎ After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58. Example: 4 Character Fixed Field

+ 4D + 41 + 49 + 4E =

MAIN

111

Page 118

Exit and Save Configuration

ADVANCED FORMATTING 8

Ì$-?Î

Second Additional Fixed Field no fixed field

ÌHJ0fÎ 1 character fixed field

ÌHJ1iÎ 2 character fixed field

ÌHJ2lÎ 3 character fixed field

ÌHJ3oÎ 4 character fixed field

ÌHJ4rÎ 5 character fixed field

ÌHJ5uÎ 6 character fixed field

ÌHJ6xÎ After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58. Example: 3 Character Fixed Field

+ 53 + 45 + 54 =

112

SET

Page 119

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

Field Transmission

9 number of fields to transmit

ÌHK8Î Read one number in the range 1 to 7 for the number of fields to transmit. Include only fields to be transmitted. Field Order Transmission Read the codes corresponding to the fields to transmit in the order in which they are to be transmitted. A field can be transmitted more than once. See example. field 1

Ì12Î field 2

Ì23Î field 3

Ì34Î field 4

Ì45Î field 5

Ì56Î additional field 1

Ì67Î additional field 2

Ì78Î Example: The barcode is divided into 3 defined fields plus 1 additional fixed field. Transmit in the order: Field 2, Additional Field 1, Field 1, Field 2. Number of Fields to Transmit

Field 2

+4+

Additional Field 1

+

Field 1

+

Field 2

+

113

Page 120

Exit and Save Configuration

ADVANCED FORMATTING 10

Ì$-?Î

Standard Formatting do not apply standard formatting

ÌHL0jÎ apply standard formatting

ÌHL1mÎ After performing Advanced Formatting on the barcode read, Standard Formatting (Headers, Code Length, Code ID, Terminators) can be applied to the message to be transmitted.

11

End Format Definition end Format 1 definition

ÌHM0lÎ end Format 2 definition

ÌHM1oÎ end Format 3 definition

ÌHM2rÎ end Format 4 definition

ÌHM3uÎ

114

Page 121

Enter Configuration

Ì$+;Î

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

Enable Advanced Format ‹ no Advanced Formats enabled

ÌHN0nÎ Advanced Format 1 enable

ÌHN11NÎ disable

ÌHN10JÎ Advanced Format 2 enable

ÌHN21QÎ disable

ÌHN20MÎ Advanced Format 3 enable

ÌHN31TÎ disable

ÌHN30PÎ Advanced Format 4 enable

ÌHN41WÎ disable

ÌHN40SÎ

115

Page 122

Enter Configuration

Ì$+;Î

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

No Match Result clear data - no transmission

ÌHO0pÎ transmit data using standard format

ÌHO1sÎ This selection determines the action to be taken when codes read do not conform to the advanced format requisites (no match). •

Codes not matching can be ignored, cleared from memory and not transmitted.

•

Codes not matching can be transmitted using the Standard formatting (Headers, Code Length, Code ID, Terminators).

116

Page 123

RADIO PARAMETERS

~ ~ ~ ~ ~

RADIO PROTOCOL TIMEOUT POWER-OFF TIMEOUT BEEPER CONTROL FOR RADIO RESPONSE SINGLE STORE BATCH MODE

~ ~ ~ ~ ~

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups. = Read the code and follow the procedure given

3.

Read the Exit and Save Configuration code ONCE, available at the top of each page.

117

Page 124

Enter Configuration

Exit and Save Configuration

Ì$+;Î

RADIO PARAMETERS

Ì$-?Î

RADIO PROTOCOL TIMEOUT radio protocol timeout

ÌRH<Î Read a number from the table where: 02-19 = timeout from 2 to 19 seconds

‹ 2 seconds

See par. 4.7.1 for details.

POWER-OFF TIMEOUT power-off timeout

ÌRPLÎ Read 2 numbers in the range 00-99: 00 = 01-99 =

Power-off disabled; reader always ready corresponds to a max. 99 hour delay before power-off.

‹ power-off after 4 hours.

See par. 4.7.2 for details.

118