Page 115
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
DEFINE FIELD 4 BY: EITHER field separator
ÌHG0`Î a)
Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator
Ì01Î
Ì12Î OR match character
ÌHG3iÎ b)
Read the match character from the HEX table. Range of characters = 01-FE. OR field length
ÌHG1cÎ c)
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
ÌHG2fÎ d)
AND Field 4 Terminators no field terminators
ÌHH0bÎ 1 field terminator
2 field terminators
ÌHH1eÎ
ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58.
109
Page 116
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
DEFINE FIELD 5 BY: EITHER field separator
ÌHG0`Î a)
Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator
Ì01Î
Ì12Î OR match character
ÌHG3iÎ b)
Read the match character from the HEX table. Range of characters = 01-FE. OR field length
ÌHG1cÎ c)
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
ÌHG2fÎ d)
AND Field 5 Terminators no field terminators
ÌHH0bÎ 1 field terminator
2 field terminators
ÌHH1eÎ
ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58.
110
Page 117
Exit and Save Configuration
ADVANCED FORMATTING
7
Ì$-?Î
First Additional Fixed Field no fixed field
ÌHI0dÎ 1 character fixed field
ÌHI1gÎ 2 character fixed field
ÌHI2jÎ 3 character fixed field
ÌHI3mÎ 4 character fixed field
ÌHI4pÎ 5 character fixed field
ÌHI5sÎ 6 character fixed field
ÌHI6vÎ After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58. Example: 4 Character Fixed Field
+ 4D + 41 + 49 + 4E =
MAIN
111
Page 118
Exit and Save Configuration
ADVANCED FORMATTING 8
Ì$-?Î
Second Additional Fixed Field no fixed field
ÌHJ0fÎ 1 character fixed field
ÌHJ1iÎ 2 character fixed field
ÌHJ2lÎ 3 character fixed field
ÌHJ3oÎ 4 character fixed field
ÌHJ4rÎ 5 character fixed field
ÌHJ5uÎ 6 character fixed field
ÌHJ6xÎ After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 01-FE. For Wedge and USB-KBD interfaces, it is also possible to read the Special Key(s) on page 58. Example: 3 Character Fixed Field
+ 53 + 45 + 54 =
112
SET
Page 119
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
Field Transmission
9 number of fields to transmit
ÌHK8Î Read one number in the range 1 to 7 for the number of fields to transmit. Include only fields to be transmitted. Field Order Transmission Read the codes corresponding to the fields to transmit in the order in which they are to be transmitted. A field can be transmitted more than once. See example. field 1
Ì12Î field 2
Ì23Î field 3
Ì34Î field 4
Ì45Î field 5
Ì56Î additional field 1
Ì67Î additional field 2
Ì78Î Example: The barcode is divided into 3 defined fields plus 1 additional fixed field. Transmit in the order: Field 2, Additional Field 1, Field 1, Field 2. Number of Fields to Transmit
Field 2
+4+
Additional Field 1
+
Field 1
+
Field 2
+
113
Page 120
Exit and Save Configuration
ADVANCED FORMATTING 10
Ì$-?Î
Standard Formatting do not apply standard formatting
ÌHL0jÎ apply standard formatting
ÌHL1mÎ After performing Advanced Formatting on the barcode read, Standard Formatting (Headers, Code Length, Code ID, Terminators) can be applied to the message to be transmitted.
11
End Format Definition end Format 1 definition
ÌHM0lÎ end Format 2 definition
ÌHM1oÎ end Format 3 definition
ÌHM2rÎ end Format 4 definition
ÌHM3uÎ
114
Page 121
Enter Configuration
Ì$+;Î
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
Enable Advanced Format ‹ no Advanced Formats enabled
ÌHN0nÎ Advanced Format 1 enable
ÌHN11NÎ disable
ÌHN10JÎ Advanced Format 2 enable
ÌHN21QÎ disable
ÌHN20MÎ Advanced Format 3 enable
ÌHN31TÎ disable
ÌHN30PÎ Advanced Format 4 enable
ÌHN41WÎ disable
ÌHN40SÎ
115
Page 122
Enter Configuration
Ì$+;Î
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
No Match Result clear data - no transmission
ÌHO0pÎ transmit data using standard format
ÌHO1sÎ This selection determines the action to be taken when codes read do not conform to the advanced format requisites (no match). •
Codes not matching can be ignored, cleared from memory and not transmitted.
•
Codes not matching can be transmitted using the Standard formatting (Headers, Code Length, Code ID, Terminators).
116
Page 123
RADIO PARAMETERS
~ ~ ~ ~ ~
RADIO PROTOCOL TIMEOUT POWER-OFF TIMEOUT BEEPER CONTROL FOR RADIO RESPONSE SINGLE STORE BATCH MODE
~ ~ ~ ~ ~
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups. = Read the code and follow the procedure given
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
117
Page 124
Enter Configuration
Exit and Save Configuration
Ì$+;Î
RADIO PARAMETERS
Ì$-?Î
RADIO PROTOCOL TIMEOUT radio protocol timeout
ÌRH<Î Read a number from the table where: 02-19 = timeout from 2 to 19 seconds
‹ 2 seconds
See par. 4.7.1 for details.
POWER-OFF TIMEOUT power-off timeout
ÌRPLÎ Read 2 numbers in the range 00-99: 00 = 01-99 =
Power-off disabled; reader always ready corresponds to a max. 99 hour delay before power-off.
‹ power-off after 4 hours.
See par. 4.7.2 for details.
118