Page 21
Programming Barcodes
Keyboard Wedge Interface, continued
Select KBD-XT (PC/XT w/Standard Key Encoding)
Select KBD-IBM-3153 (for IBM Terminal 3153)
Select KBD-IBM-M (for IBM Terminals 31xx, 32xx, 34xx, 37xx make only keyboard)
Select KBD-IBM-MB (for IBM Terminals 31xx, 32xx, 34xx, 37xx make break keyboard)
Select KBD-DIG-VT (for DIGITAL Terminals VT2xx, VT3xx, VT4xx)
Quick Reference Guide
19
Page 22
Ergonomic Recommendations
Ergonomic Recommendations CAUTION
•
In order to avoid or minimize the potential risk of ergonomic injury follow the recommendations below. Consult with your local Health & Safety Manager to ensure that you are adhering to your company’s safety programs to prevent employee injury.
Reduce or eliminate repetitive motion
•
Maintain a natural position
•
Reduce or eliminate excessive force
•
Keep objects that are used frequently within easy reach
•
Perform tasks at correct heights
•
Reduce or eliminate vibration
•
Reduce or eliminate direct pressure
•
Provide adjustable workstations
•
Provide adequate clearance
•
Provide a suitable working environment
•
Improve work procedures.
Regulatory Information All models are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Any changes or modifications to equipment, not expressly approved by Datalogic could void the user's authority to operate the equipment.
Power Supply This device is intended to be connected to a UL Listed/CSA Certified computer which supplies power directly to the reader or else be supplied by UL Listed/CSA Certified Power Unit marked “Class 2” or LPS power source rated 4.5-14 minimum 600mA for GD4110 or rated 5.2V minimum 600mA for GD4130, which supplies power directly to the reader via the power connector of the cable.
20
Gryphon™ I GD4100
Page 23
Quick Reference Guide
X
X
X
Printed Circuit Board Assembly
Assy, Optics Block
Assy, Module
O
O
O
ᳮ
Mercury (Hg)
O
O
O
叏
Hexavalent Chromium (Cr(VI))
O
O
O
ચ卲
O
O
O
ᄙᄽ侶
O
O
O
ᄙᄽԲㅘ
Polybrominated diphenyl ethers (PBDE)
China RoHS Polybrominated biphenyls (PBB)
Ქኂ‛凝ᚗర⚛
Cadmium (Cd)
ޝ䶣ॾஒ䣈խڶڶ୭ढ凝ऱૻၦޣρ(SJ/T 11363-2006) 億ࡳऱૻၦޕ ⥋ዋ৻㮕᧚ᢱᚲ⊛Ქኂ‛凝Պխ䦀Գا٥ࡉ㧺ॾஒ䣈䢓ຝᚲ咒ؒ⊛ ޝ䶣ॾஒ䣈խڶڶ୭ढ凝ऱૻၦޣρ(SJ/T 11363-2006) 億ࡳऱૻ㊂
卋
ㇱઙฬ⒓
PART
Lead (Pb)
Regulatory Information
21
Page 24
Regulatory Information
Radio Frequency Interference Requirements This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If the equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Tested to comply with FCC Standards
FOR HOME OR OFFICE USE
•
Re-orient or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
CAUTION
The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Radio Frequency Interference Requirements - Canada This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
22
Gryphon™ I GD4100
Page 25
Imager Labeling
Imager Labeling Labels are shown here to illustrate their location only. Please view the labels on your product for actual details.
US
N263
R
239045
IC SCANNING USA DATALOG , OREGON EUGENE AGE FOR SEE P ACK NG PATENT LISTI PRODUCT LED CLAS S 1 INC.
This devic O pe ra ti e complies with o n is s u bje c t o PART 15 of the (1) this devic the fo llo FCC Rules (2) this devic e may not cause wing . e must accep harmful two c o nd itio ns including : interf See manu interference thatt any interferenc erence, and e receiv al for FCC may cause details. undesired ed, operation
C
10
Regulatory & Serial Number
Waste Electrical and Electronic Equipment (WEEE) Statement
English For information about the disposal of Waste Electrical and Electronic Equipment (WEEE), please refer to the website at www.scanning.datalogic.com. Italian Per informazioni sullo smaltimento delle apparecchiature elettriche ed elettroniche consultare il sito Web www.scanning.datalogic.com. French Pour toute information relative à l’élimination des déchets électroniques (WEEE), veuillez consulter le site internet www.scanning.datalogic.com. German Informationen zur Entsorgung von Elektro- und Elektronik- Altgeräten (WEEE) erhalten Sie auf der Webseite www.scanning.datalogic.com. Spanish Si desea información acerca de los procedimientos para el desecho de los residuos del equipo eléctrico y electrónico (WEEE), visite la página Web www.scanning.datalogic.com. Portuguese Para informações sobre a disposição de Sucatagem de Equipamentos Elétricos e Eletrônicos (WEEE -Waste Electrical and Electronic Equipment), consultar o site web www.scanning.datalogic.com. Chinese 有关处理废弃电气电子设备 (WEEE) 的信息, 请参考 Datalogic 公 司的网站: http://www.scanning.datalogic.com/。 Japanese 廃電気電子機器 (WEEE) の処理についての関連事項は Datalogic のサイト www.scanning.datalogic.com をご参照下さい。
Quick Reference Guide
23
Page 26
Imager Labeling
Warranty Datalogic warrants to Customer that Datalogic's products will be free from defects in materials and workmanship for a period of 5 years from product shipment. This warranty does not extend to batteries and cables. As consumable items batteries and cables carry a 90 day warranty from time of purchase for DOA (dead on arrival) defects. In order to obtain service under this Warranty, Customer must notify Datalogic of the claimed defect before the expiration of the Warranty period and obtain from Datalogic a return authorization number for return of the product to designated Datalogic service center. If Datalogic determines Customer’s claim is valid, Datalogic will repair or replace product without additional charge for parts and labor. Customer shall be responsible for packaging and shipping the product to the designated Datalogic service center, with shipping charges prepaid. Datalogic shall pay for the return of the product to Customer if the shipment is to a location within the country in which the Datalogic service center is located. Customer shall be responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to any other locations. Warranty is subject to the limitations and exclusions set forth in the paragraphs that follow. WARRANTY SET FORTH ABOVE IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS.
Exclusions Warranty coverage shall not apply to any claimed defect, failure or damage which Datalogic determines was caused by: improper use of product; failure to provide product maintenance, including but not limited to cleaning of the upper window in accordance with product manual; installation or service of product by other than Datalogic representatives; use of product with any other instrument, equipment or apparatus; modification or alteration of product. External cables and replacement of upper window/cartridge due to scratching, stains or other degradation will not be covered under the Warranty. External power supplies returned for service must be accompanied by the original product for performance of service.
Limitation of Liability Datalogic's REPAIR OR REPLACEMENT OF DEFECTIVE PRODUCT AS SET FORTH ABOVE IS THE CUSTOMER’S SOLE AND EXCLUSIVE REMEDY ON ACCOUNT OF CLAIMS OF BREACH OF WARRANTY OR PRODUCT DEFECT. UNDER NO CIRCUMSTANCES WILL Datalogic BE LIABLE TO CUSTOMER OR ANY THIRD PARTY FOR ANY LOST PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL IN-DIRECT, SPECIAL OR CONTINGENT DAMAGES REGARDLESS OF WHETHER Datalogic HAD ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.
Assignment Customer may not assign or otherwise transfer its rights or obligations under Warranty except to a purchaser or transferee of product. No attempted assignment or transfer in violation of this provision shall be valid or binding upon Datalogic.
Risk of Loss Customer shall bear risk of loss or damage for product in transit to Datalogic. Datalogic shall assume risk of loss or damage for product in Datalogic's possession or product being returned to Customer by Datalogic, except such loss or damage as may be caused by the negligence of Customer, its agents or employees. In the absence of specific written instructions for the return of product to Customer, Datalogic will select the carrier, but Datalogic shall not thereby assume any liability in connection with the return shipment.
24
Gryphon™ I GD4100
Page 27
DECLARATION OF CONFORMITY Datalogic Scanning Group Srl Via S. Vitalino, 13 Lippo di Calderara di Reno (BO) 40012 Italy
09 dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el Gryphon™ D41xx Black and Gryphon D41xx White e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: den nachstehenden angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente: 89/336/EEC EMC Directive e and
92/31/EEC, 93/68/EEC emendamenti successivi further amendments et ses successifs amendements und späteren Abänderungen y succesivas enmiendas
Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti. On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety. Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits. Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen. Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto. Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas: EN 55022 (CLASS B ITE), August 1994: Amendment A1 (Class B ITE), October 2000:
Limits and methods of measurements of radio disturbance characteristics of information technology equipments
EN 55024, September 1998:
Information technology equipment Immunity characteristics Limits and methods of measurement
Lippo di Calderara, February 24th , 2009
Ruggero Cacioppo Quality Assurance Manager
Page 28
Australia Datalogic Scanning Pty Ltd Telephone: [61] (2) 9870 3200 australia.scanning@datalogic.com
Japan Datalogic Scanning KK Telephone: 81 (0)3 3491 6761 japan.scanning@datalogic.com
France and Benelux Datalogic Scanning SAS Telephone: [33].01.64.86.71.00 france.scanning@datalogic.com
Latin America Datalogic Scanning, Inc Telephone: (305) 591-3222 latinamerica.scanning@datalogic.com
Germany Datalogic Scanning GmbH Telephone: 49 (0) 61 51/93 58-0 germany.scanning@datalogic.com
Singapore Datalogic Scanning Singapore PTE LTD Telephone: (65) 6435-1311 singapore.scanning@datalogic.com
India Datalogic Scanning India Telephone: 91- 22 - 64504739 india.scanning@datalogic.com
Iberia Datalogic Scanning SAS Sucursal en España Telephone: 34 91 746 28 60 spain.scanning@datalogic.com
Italy Datalogic Scanning SpA Telephone: [39] (0) 39/62903.1 italy.scanning@datalogic.com
United Kingdom Datalogic Scanning LTD Telephone: 44 (0) 1582 464900 uk.scanning@datalogic.com www.scanning.datalogic.com Datalogic Scanning, Inc. 959 Terry Street Eugene, OR 97402 USA Telephone: (541) 683-5700 Fax: (541) 345-7140
© 2009 Datalogic Scanning, Inc.
820002352 (Rev. E)
11/09