Page 11
Aim and Scan
RS-232 Interface
USB Interface
3
Aim and Scan
012345
Quick Reference Guide
012345
9
Page 12
Parts of the Imager
Parts of the Imager LED
Scan Window Trigger
Scanning Modes The imager can operate in one of several scanning modes: Trigger Single, When the trigger is pulled, scanning is activated until one of the following occurs: - a programmable duration1 has elapsed - a label has been read - the trigger is released This mode is associated with typical handheld reader operation: when the trigger is pulled, scanning starts and the product scans until the trigger is released, or a label is read, or the maximum programmable duration1 has elapsed. Trigger Hold Multiple, When the trigger is pulled, scanning starts and the product scans until the trigger is released or a programmable duration1 has elapsed. Reading a label does not disable scanning. Double Read Timeout2 prevents undesired multiple reads while in this mode. Trigger Pulse Multiple, When the trigger is pulled and released, scanning is activated until programmable duration1 has elapsed or the trigger has been pulled again to transition to another state. Double Read Timeout2 prevents undesired multiple reads while in this mode. 1. 2.
10
See the Product Reference Guide (PRG) for additional programmable features, in this case: Scanning Active Time. Double Read Timeout is also programmed using the PRG.
Gryphon™ I GD4100
Page 13
Scanning Modes
Flashing, The reader flashes1 on and off regardless of the trigger status. Always On, No trigger pull is required to read a barcode. Scanning is continually on. If the trigger is pulled, the reader acts as if it is in Trigger Single Mode. Double Read Timeout2 prevents undesired multiple reads while in this mode. Object Sense, No trigger pull is required to read a bar code. Scanning is turned on automatically when an item is placed in reader’s field of view. If the trigger is pulled, the reader acts as if it is in Trigger Single mode. Double Read Timeout3 prevents undesired multiple reads while in this mode. Trigger Object Sense, This mode is similar to Object Sense, except that a trigger pull is required to activate the decoder.
Scan Mode = Trigger Single
Scan Mode = Trigger Hold Multiple
Scan Mode = Trigger Pulse Multiple
1. 2. 3.
Controlled by Flash On Time and Flash Off Time. Use the PRG to program these options. Double Read Timeout is programmed using the PRG. Double Read Timeout is programmed using the PRG.
Quick Reference Guide
11
Page 14
Scanning Modes
Scanning Modes, continued
Scan Mode = Flashing
Scan Mode = Always On
Scan Mode = Object Sense
Scan Mode = Trigger Object Sense
12
Gryphon™ I GD4100
Page 15
Troubleshooting
Troubleshooting Problem
Possible Cause
Nothing happens when No power to the the scan button is pulled. imager.
LED comes on, but barcode does not decode.
Barcode is decoded but not transmitted to the host.
Possible Solutions Check system power. Ensure power supply is connected.
Interface or power cables are loose.
Ensure all cable connections are secure.
Imager not programmed for correct barcode type.
Ensure imager is programmed to read the type of barcode scanned. Refer to the Product Reference Guide (PRG) for more information.
Barcode label is unreadable.
Check the label to ensure it is not defaced. Try scanning another barcode type.
Distance between imager and barcode is incorrect.
Move imager closer to or further from the barcode.
Imager not programmed for the correct host type.
Scan the appropriate host type barcode. Refer to the Product Reference Guide (PRG) for more information.
For detailed troubleshooting, refer to the Product Reference Guide.
Quick Reference Guide
13
Page 16
LED and Beeper Indications
LED and Beeper Indications The imager’s beeper sounds and its LED illuminates to indicate various functions or errors on the reader. A “Green Spot” also lights to indicate a good read. The tables below list these indications. One exception to the behaviors listed in the tables is that the reader’s functions are programmable, and may or may not be turned on. For example, certain indications, such as the power-up beep can be disabled using programming barcode labels. Reference the PRG for a more detailed list. Indication
LED
Beeper
Power-up
LED flashes/blinks on power-up, however, this may Imager beeps four times at be too rapid to view. With a highest frequency and volUSB interface, the LED blinks ume upon power-up. until enumeration with the host is completed.
Good Read
One beep at current freLED behavior for this indicaquency, volume, tion is configurable using the mono/bi-tonal setting upon PRG. a successful label scan.
ROM Failure
200ms on / 200ms off
Imager sounds one error beep at highest volume for 200 mS.
Limited Scanning Label Read
N/A
Imager 'chirps' six times at the highest frequency and current volume.
Imager Disabled
The LED blinks continuously 100mS on / 900 mS off
N/A
14
Gryphon™ I GD4100
Page 17
Programming Barcodes
Programming Barcodes For your convenience, this guide includes the programming barcodes required to configure the imager for use with different interface (terminal/host) types. See the Product Reference Guide (PRG) for more complete information about programming and configurable features. You can download the latest version of the PRG and any other available publications for the imager from the website listed on the back cover of this manual.
Resetting the Standard Product Defaults If you aren’t sure what programming options are in your imager, or you’ve changed some options and want the factory settings restored, scan the Factory Default Settings barcode below. This will copy the factory configuration for the currently active interface to the current configuration.
Factory Default Settings Some interfaces require the scanner to start in the disabled state when powered up. If additional scanner configuration is desired while in this state, pull the trigger and hold it for five seconds. The scanner will change to a state that allows programming with barcodes.
Quick Reference Guide
15
Page 18
Programming Barcodes
RS-232 Interface To use an RS-232 interface, scan the barcode for the desired RS-232 host type.
Select RS-232 Standard
Select RS-232 Wincor Nixdorf
Select RS-232 OPOS (for use with OPOS/UPOS/JavaPOS)
IBM Interface
Select IBM Port 5B
Select IBM Port 9B
16
Gryphon™ I GD4100
Page 19
Programming Barcodes
USB Interface The imager attaches directly to a USB host, or a powered USB hub, and is powered by it. No additional power supply is required. When using a USB interface, the imager auto-detects the USB cable and defaults to either the USB keyboard interface (GD4130) or USB-OEM interface (GD4110).
Select USB Keyboard (with standard key encoding)
Select USB-COM-STD1 (simulates RS-232 standard interface)
Select USB Alternate Keyboard (with alternate key encoding)
Select USB OEM
Select USB-KBD-APPLE (for Apple computers)
1.
Download the correct USB Com driver from www.datalogic.com.
Quick Reference Guide
17
Page 20
Programming Barcodes
Keyboard Wedge Interface To use a Keyboard Wedge interface, scan the barcode for the desired keyboard type.
Select KBD-AT (AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding)
Select KBD-AT-NK (IBM AT PS2 with standard key encoding but without external kbd.)
Select KBD-AT-ALT (AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key)
Select KBD-AT-ALT-NK (for IBM AT PS2 with alternate key encoding but without external keyboard)
18
Gryphon™ I GD4100