Page 38
F734-E SERIES TERMINALS
4
4
MAINTENANCE
NOTE
4.1
Rechargeable battery packs (NiCd/NiMh) are not initially charged. Therefore the first operation to perform is to charge them in the appropriate cradle. See chapter 2 and the following paragraph "Charging the Batteries".
CHARGING THE BATTERIES
Battery charge life depends on many variables but, under normal conditions, autonomy is more than enough for a day work. Information on the battery-charge status is provided by the . The information provided by the dedicated icon on the display icon is valid only when the terminal is not inserted in the cradle. Four different charge levels are given from a maximum value (all the icon segments full) to a minimum one which warns of pre-lowbattery (icon empty and intermittently flashing). Recharging should be made after using the terminal until the batteries are nearly flat.
When the terminal display window shows the message "BATTERY LOW", wait until it is turned off before inserting it in the cradle. CAUTION Recharge the terminal by simply inserting it into its cradle; Datalogic Mobile S.r.l. recommends a minimum uninterrupted recharging time of eight hours. When using the NiMh battery a standard recharge does not allow taking fully advantage of the improved battery technology. For this reason, a recharging time of about 60 hours is advised to get the NiMh maximum capacity. When batteries are new, or have not been recharged for a long time, it is necessary to perform two or three charge and discharge cycles (with complete use) before the batteries are able to reach their maximum capacity.
22
Page 39
MAINTENANCE
NOTE
CAUTION
4
During the battery recharge the color of the LED positioned on the cradle changes from red to green. If using the NiCd battery pack, the LED color changes when 70-80% of the complete charge is reached. If using the NiMh battery pack, the LED color changes when 50-60% of the complete charge is reached due to the battery increased capacity.
If the terminal remains inactive for a prolonged period such as two weeks, it is advisable to download all the stored data onto a computer and extract the battery pack.
23
Page 40
F734-E SERIES TERMINALS
4
4.2
REPLACING THE BATTERIES Before proceeding, ensure that the terminal is switched off and that the data it contains has been downloaded onto the host computer.
CAUTION
To replace the batteries correctly, proceed as follows. 1-
Turn over the terminal and remove the two battery cover screws.
2-
Lift the battery cover as shown in the figure and extract the old battery pack.
1 2
24
Page 41
MAINTENANCE 3-
4
Replace the battery pack, making sure the batteries are inserted in the right direction as indicated within the case.
-+ -
+
Before inserting the battery pack into the terminal, ensure the battery polarity matches with the one indicated within the case. CAUTION
CONTACTS
Figure 19
CAUTION
4-
Figure 20
When inserting the battery pack, first slide it towards the springs compressing them until the contacts at the other end are cleared (see Figure 18). Then, push downwards to insert the pack (see Figure 19). Be very careful not to damage the contacts when pushing downwards.
Close the battery cover and tighten the screws
WARNING
Do not incinerate, disassemble, short terminals or expose to high temperature. Risk of fire, explosion. Use specified charger only. Risk of explosion if the battery is replaced by an incorrect type. Dispose of the batteries as required by the relevant laws in force.
25
Page 42
4
4.3
F734-E SERIES TERMINALS
CLEANING THE TERMINAL
Clean the terminal from time to time with a slightly damp cloth. Do not use alcohol, corrosive products or solvents.
26