The text of a manual · part 5 of 8

F734-E Series Terminals User's Manual: USE AND OPERATION

Pages 32 to 37 of 50, from F734-E Series Terminals User's Manual

The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic Formula 734

Page 32

F734-E SERIES TERMINALS

3

3

USE AND OPERATION

The F734-E and F734-E/RF are lightweight, pocket-sized and fully programmable terminals with 512 KB (512/1024 KB for F734-E model) of RAM memory to manage large databases and 512 KB of Flash memory for application programs of large dimensions.

It is necessary to load an application program onto the terminal to exploit its features. NOTE By using the optional EasyGen™ Application Generator or the DS for Formula™ software package, developers can easily customize applications according to the end user specific needs, solving the most common data collection applications such as inventory, picking and shipping/receiving. The Demo Version of EasyGen™ can be downloaded free of charge from the Datalogic Mobile web site together with 5 ready-touse example applications in 5 different languages. Refer to chapter 6 of the EasyGen™ User's Manual for details. The following descriptions assume the terminal is loaded with an EasyGen™ application. If however, a custom application is loaded then refer to the specific documentation for terminal operation.

3.1

DESCRIPTION OF KEYS USING EASYGEN™

It is possible to assign customized functions to function keys depending on the application program developed. The functions described below refer to a terminal using an application program developed with the EasyGen™ Application Generator.

Refer to chapter 6 "EasyGen™ Interpreter Program" of the EasyGen™ User's Manual for more details about the key functions. CAUTION

Every time a key is pressed, the F734-E series terminal remains turned on for a maximum of 20 seconds. NOTE

16

Page 33

USE AND OPERATION

3

ARROW KEYS: only available for the application when not in “Select or Data Edit” mode. SCAN KEY: activates the laser for barcode scanning and turns on the terminal when it is off. FUNCTION KEYS: keys <F1>, <F2>, <F3> and <F4> are available for the loaded application. Function F5 activates the “Select” mode and only in this mode you can use F6, F7 and F8 functions: <SHIFT> followed by <F1> = F5 “Select” mode <SHIFT> followed by <F2> = F6 Data search <SHIFT> followed by <F3> = F7 Deletion <SHIFT> followed by <F4> = F8 Data display ESC KEY: used in the “Data display” mode. SHIFT KEY: Enables the entry of alphabetical characters (written in white on the keyboard) when followed by the pressing of a numeric key: for example if you want to enter the alphabetical character “A”, you have to press <SHIFT>+<7>. The number of times the SHIFT key is pressed determines the choice of alphabetical character: for example if you want to enter the alphabetical character “N”, you have to press <SHIFT>+<SHIFT>+<5>, if you want to enter the alphabetical character “X”, you have to press <SHIFT>+<SHIFT>+<SHIFT>+<2> and so on. The fourth time the SHIFT key is pressed, the SHIFT function is disabled. The SHIFT function can also be disabled by waiting for a time-out of 2 seconds after being pressed.

By pressing the <SHIFT> key followed by the <RIGHT ARROW> key, the graphic 17

Page 34

3

F734-E SERIES TERMINALS display’s contrast increases to the allowed maximum, and then returns to 0 value. NUMERIC KEYS: allow the entry and display of the main numeric symbol. If the <SHIFT> has first been pressed, the choice of alternative alphabetic characters will be activated.

BACKSPACE KEY: character entered.

deletes the last

SPACE KEY: allows the introduction of a blank space. If the <SHIFT> has been pressed previously, the choice of alternative characters will be activated. ENTER KEY: allows validation of what has been typed. PROTECTED RESET BUTTON: it is activated by inserting a blunt object in the slot while simultaneously pressing the <SCAN> key.

18

Page 35

USE AND OPERATION

3.2

3

BARCODE SCANNING

When reading a barcode point the terminal laser beam at the code from an appropriate distance and simultaneously press the <SCAN> key. The beam emitted by the laser must completely cover the barcode; the LED (and the acoustic signal, if activated) will indicate if the scan was carried out correctly.

NO

NO

OK

OK

Figure 16 - F734-E Series Terminal Scanning a Barcode

NOTE

Throughout the operation of the application, the , and the time icon will always be battery icon activated, the latter in accordance with the setting of the terminal internal clock. In addition, when an acoustic signal is emitted, will appear. the loudspeaker icon

19

Page 36

F734-E SERIES TERMINALS

3

3.3

DELETING THE APPLICATION PROGRAM

This procedure allows deleting application programs developed with DS for Formula™. If you want to delete programs provided or developed by EasyGen™, refer to chapter 6 of the EasyGen™ manual.

The following procedure causes data to be deleted even if not completed. NOTE

If the application program must be cancelled follow the instructions below: 1-

Press the <SCAN> key and the protected reset button at the same time; the display will show:

PROGRAM ERASE? = No Yes =

If you do not want to delete the application program, press the {▲} or wait about 25 seconds. NOTE 2-

To continue with the deletion, press the ▼ key; after a few seconds, the display will show:

BOOTSTRAPLOADER v6r1 ErasPrgFlash

3-

20

Once the deletion procedure is completed, the terminal is ready to receive a new application program. This is installed using the methods described in the DS for Formula™ manual.

Page 37

USE AND OPERATION

3.4

3

DOWNLOADING DATA TO HOST

Data can be downloaded from the terminal to the host PC in different ways, depending on the application loaded and on the terminal model. If working with F734-E (batch model), the application software allows downloading data onto the PC by simply inserting the terminal into the cradle or by direct operator intervention on the terminal or host computer.

Figure 17 - Downloading Data with F734-E

If working with F734-E/RF, the application software will allow downloading data by radio frequency transmission between the terminal and a STARGATE™ RF base station.

Figure 18 - Downloading Data with F734-E/RF

21