INSTALLATION
2.3.4
2
DeviceNet Connector
The 5-pin male connector is only available in the DX8200A DeviceNet model and allows connection between the host and the reader:
4
3
1
2
5
Figure 27 - DeviceNet 5-pin Male Connector
DX8200A 5-pin DeviceNet connector pinout Pin 2 5 1 4 3
NOTE
Name V+ CAN_L SHIELD CAN_H V-
Function Supply voltage – positive pin CAN bus data line – L Shield CAN bus data line – H Supply voltage – negative pin
The power supplied on pin V+ and V- is used only to propagate power to the section of the DeviceNet board directly connected to the Bus. It is completely isolated from the DX8200A power which must be supplied on pin 9, 13 and pin 23, 25 of the 26-pin Main/Aux connector.
23
Page 40
DX8200A
2
2.3.5
Profibus Connector
The 9-pin Profibus female connector (white) is only available in the DX8200A Profibus model and allows connection between the host and the reader: 1
5
9
6
Figure 28 - Profibus 9-pin Female Connector
DX8200A 9-pin Profibus connector pinout Pin 1 2 3 4 5 6 7 8 9 * **
Name Shield* Free B-LINE (RxD/TxD-P) CNTR-P** DGND +5 V Free A-LINE (RxD/TxD-N) CNTR-N**
Function Shield, Protective Ground resp. Received/Transmitted Data-P Repeater Control Signal Data Ground (M5V) Voltage Plus (P5V) Received/Transmitted Data Repeater Control Signal signal is optional signal is optional; RS485 level
Profibus Interface The Profibus interface is used for communication with an Host and allows expanding the networking and remote diagnostic capabilities of the scanner. For further details refer to the “Profibus_Fam6k.pdf” document provided as supplementary documentation.
2.3.6
Power Supply
Vdc models: The supply voltage for correct operation of the scanner must be between 20 and 30 VDC. The max. power consumption is 35 W including startup current. Several accessory power supplies are available to power the DX8200A VDC models and reading station components. See par. 1.5. A security system allows the laser to activate only once the motor has reached the correct rotational speed; consequently, the laser beam is generated after a slight delay from the power on of the scanner.
24
Page 41
INSTALLATION
2
Note that GND is internally connected to chassis. The cable shield is also connected to pin 1 - CHASSIS. DX8200A
USER INTERFACE 9/13
VS
23/25
GND
1
CHASSIS
V+ (20 – 30 Vdc) V- (Ground)
Chassis
Earth Ground
Figure 29 – Power Supply Using the 26-pin Connector
Vac models: The supply voltage for correct operation of the scanner must be between 110 and 230 VAC. The max. power consumption is 35 VA including startup current. 24 Vdc is generated and available on the 26-pin connector and can be used to power external devices through a modified C-BOX 100, i.e. photocell, etc. This voltage however cannot be used to propagate power for a Lonworks network. A security system allows the laser to activate only once the motor has reached the correct rotational speed; consequently, the laser beam is generated after a slight delay from the power on of the scanner.
2.4 USER INTERFACE How to Build a Simple Interface Test Cable: The following wiring diagram shows a simple test cable including power, external (push-button) trigger and PC RS232 COM port connections. 26-pin D-sub female
9-pin D-sub female
21
TXAUX
2
RX
20
RXAUX
3
TX
5
GND
23 GND
PC
13 VS 25 GND
DX8200A
9
VS
18 EXT TRIG A 19 EXT TRIG B
Power Supply VS (20 – 30 VDC) Power GND
Trigger
Test Cable for DX8200A
25
Page 42
DX8200A
2
2.5 TYPICAL LAYOUTS The DX8200A scanners can be connected in a variety of layouts depending on the number of scanners used and the required complexity of the reading station. These layouts range from Single Stand Alone to Complex Lonworks Networks. Vac models can be used for point-to-point connections eliminating the need for an external PWR power supply. They can also be used in Lonworks layouts as long as no power cables are used, (sufficient power is not available to be propagated to other scanners in the network). For Vdc models several power supplies are available to power the reading stations. Photoelectric sensors used as code presence sensors and optical encoders to signal conveyor speed are also available accessories. The following typical layouts refer to the system hardware configurations, but they also require the correct setup of the software configuration parameters (see par. 3.2 for details). The accessories and cables indicated in the following figures are Datalogic products. We suggest their use to guarantee the correct system functioning.
2.5.1
Point-to-Point
Using a Point-to-Point layout, the data is transmitted on the Main interface as well as on the Auxiliary interface. The Main interface can be selected for RS232 or RS485 full-duplex communications. Two different layouts are available according to the DX8200A reader model used for the connection. Standard Models When On-Line operating mode is used, the reader is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone. In the following case, the signal is passed to the DX8200A by the C-BOX 100, which also supplies the system. Standard CAB601X
C-BOX 100
Local Host Presence Sensor*
PWR-120
*
P.S. (Presence Sensor) connected to External Trigger/PS input.
Figure 30 – Point-to-Point for Standard DC Models
26
Page 43
INSTALLATION
2
In general, for all point-to-point layouts, DX8200A Vac models can substitute the Vdc model and therefore eliminate the PWR power supply. This requires that the C-BOX 100 must be modified to accept scanner power for the P.S. Standard CAB601X
C-BOX 100**
110 - 230 Vac Local Host Presence Sensor*
*
P.S. (Presence Sensor) connected to External Trigger/PS input.
** C-BOX 100 modified to accept scanner power
Figure 31 – Point-to-Point for Standard AC Models
Fieldbus Models In this case no External Trigger is used and the C-BOX 100 only supplies the reader. The DX8200A (Ethernet, DeviceNet or Profibus model) is connected to a fieldbus remote Host. It can be activated by a signal generated by the remote Host or always be active if working in Automatic operating mode. Remote Host
Fieldbus Network
CAB601X Fieldbus C-BOX 100
PWR-120
Figure 32 – Point-to-Point for Fieldbus DC Models
27
Page 44
DX8200A
2
2.5.2
Pass Through
When Pass Through is activated on the Auxiliary interface, the DX8200A reader can be integrated in a network consisting of different scanners not provided with a Lonworks interface. This connection mode allows two or more devices to be connected to a single external serial interface. The DX8200A transmits the messages received by its auxiliary interface onto its main interface. In this configuration a series of scanners can be connected together using RS232 on the main interface and all messages will be passed through this chain to the host. The reading phase of each scanner is independent from the others. In Pass Through connections each scanner is provided with its relative External Trigger (multi P.S.). Applications can be implemented to connect a device such as a hand-held reader to the Auxiliary port for manual code reading capability. For the RS232 connections the maximum cable length is 15 m (50 ft). The DS4600A scanners represented in the following figures are configured in Pass Through mode.
P.S.*
P.S.*
Gryphon DX8200A DS4600A
CAB601X C-BOX 100 MAIN
C-BOX 100
DS4600A
C-BOX 100
AUX.
P.S.* 2 1
1
2
1
Local Host
PWR-120
1
Main Serial Interface
2
Auxiliary Serial Interface
*
P.S. (Presence Sensor) connected to External Trigger/PS input.
Figure 33 – Pass Through Connection for DX8200A Standard Models
28
Page 45
INSTALLATION
2
PLC Host P.S.*
P.S.* Gryphon
Fieldbus Network DX8200A
DS4600A
DS4600A CAB601X
C-BOX 100
C-BOX 100
C-BOX 100
AUX
P.S.* 2
1
2
1
PWR-120
1
*
Main Serial Interface
2
Auxiliary Serial Interface
Presence Sensor connected to External Trigger/PS input.
Figure 34 – Pass Through Connection for Fieldbus Models
2.5.3
RS232 Master/Slave
The RS232 master/slave connection is used to integrate a DX8200A reader in a network consisting of different scanners not provided with a Lonworks interface. The Slave scanners use RS232 only on the main and auxiliary interfaces. Each slave scanner transmits the messages received by the auxiliary interface onto the main interface. All messages will be transferred towards the master. The master scanner is connected to the Host PC on the main RS232 serial interface through the C-BOX 100 (20 mA C.L. can also be used if the INT-30 accessory is installed). In RS232 Master/Slave connections the External Trigger signal is unique to the system (single P.S.).
NOTE
The DX8200A Standard model, working as Master in an RS232 network, may be simultaneously connected to a Lonworks network consisting of DX8200A slave scanners. Be careful when assigning the slave address, since the number of the first Lonworks slave must be a progressive number with respect to the address number defined for the last slave scanner of the RS232 network. For example, if the RS232 network consists of Slave 1 and Slave 2, the address to be assigned to the first Lonworks slave scanner will be Slave 3 (not Slave 1).
29
Page 46
DX8200A
2
CAB601X
DS4600A Slave 1
1
C-BOX 100
DX8200A Master
AUX MAIN
P.S.* 2 Local Host
1 2
C-BOX 100 DS4600A Slave 2 PWR-120 C-BOX 100
1
1
*
2
Main Serial Interface
Auxiliary Serial Interface
P.S. (Presence Sensor) connected to External Trigger/PS input.
Figure 35 – RS232 Master/Slave for DX8200A Standard Models
Remote PLC
DX8200A Master CAB601X
Fieldbus Network
C-BOX 100 AUX
DS4600A Slave 2 P.S.* 2 1 C-BOX 100
DS4600A Slave 1
PWR-120 C-BOX 100
* Presence Sensor connected to External Trigger/PS input. 1
Main Serial Interface
2
2 1
Auxiliary Serial Interface
Figure 36 – RS232 Master/Slave for DX8200A Fieldbus Models
30
Page 47
INSTALLATION
2.5.4
2
Multiplexer
The Multiplexer connection is used to integrate a DX8200A slave reader in a Multidrop network consisting of different scanners not provided with a Lonworks interface. Each scanner is connected half-duplex main interface. P.S.* to a
Multiplexer
(MX4000)
with the
RS485
P.S.*
P.S.*
DX8200A <
DS4600A
<
DS4600A
EN T
<
<
EN T
C-BOX 100
C-BOX 100
C-BOX 100
#31
#1
#0
PWR-120
MX4000
1 Local Host
1 *
RS485 HD Main Interface P.S. (Presence Sensor) connected to External Trigger/PS input.
Figure 37 – Multiplexer for DX8200A Standard Models
The auxiliary serial interface of the slave scanners can be used to visualize collected data or to configure it using the Genius™ utility. When On-Line operating mode is used, the scanner is activated by an External Trigger when the object enters its reading zone.