Page 30
DX8200A
2 DX8200A
EXTERNAL TRIGGER/ENCODER Vext A/B
+ 5V
~
V
-
+ ~
B/A
Ground
Figure 10 - NPN Command Input Connection using External Power
DX8200A
EXTERNAL TRIGGER/ENCODER VS A/B
+ 5V
~ +
V
-
~
B/A GND
Ground
Figure 11 - NPN Command Input Connection using Scanner Power
Vext
DX8200A
EXTERNAL DEVICE V
IN3A + 5V
~ +
-
~
Ground
Vext V IN4A + 5V
~ + ~
-
INREF
Ground
Figure 12 – IN3/IN4 PNP Input Command using External Power
14
Page 31
INSTALLATION
2 DX8200A
EXTERNAL DEVICE VS
INREF + 5V
~ +
V
-
~
IN3A Ground
EXTERNAL DEVICE + 5V
~ +
V
-
~
IN4A GND
Ground
Figure 13 - IN3/IN4 NPN Input Command using Scanner Power
Input devices can be supplied by either scanner power (VS and GND) or external power supplies (Vext). Electrical isolation between the input command logic and the scanner is maintained when powering the input devices from an external supply voltage (Vext). The driving logic of the input signals may be powered, for convenience, with the voltage supply between pins 9 (VS) and 23 (GND) of the 26-pin I/O connector. In this case, however, the device is no longer electrically isolated. The voltage available on the 26-pin I/O connector, is physically the same as used to power the scanner. The electrical features of these inputs are: Maximum voltage 30 V Maximum current 10 mA
15
Page 32
DX8200A
2
Outputs Three general purpose outputs are available. Pin 8 22 11 12 16 17
Name OUT 1+ OUT 1OUT 2+ OUT 2OUT 3A OUT 3B
Function Configurable digital output 1 – positive pin Configurable digital output 1 – negative pin Configurable digital output 2 – positive pin Configurable digital output 2 – negative pin Configurable digital output 3 – polarity insensitive Configurable digital output 3 – polarity insensitive
The function of the three outputs OUT1, OUT2 and OUT3 can be defined by the user. Refer to Genius™ Help On-Line for further details. By default, OUT1 is associated with the COMPLETE READ event, which activates when the code has been read correctly. In case the reader has been programmed to read several codes within the same reading phase, the event activates when all codes have been read. OUT2 is associated with the NO READ event, which activates when no code has been read. OUT3 is associated with NONE, which means that the output is always in the Line State. The OUT1 and OUT2 electrical features are given below: Collector-emitter voltage Collector current (pulse) Collector current (continuous) Saturation voltage (VCE) Maximum power dissipation
30 V Max. 130 mA Max. 40 mA Max. 1 V at 10 mA Max. 90 mW at 50°C (Ambient temperature).
The limit requested by the maximum power dissipation is more important than that of the maximum collector current: if one of these outputs is continuously driven, the maximum current must not be more than 40 mA although 130 mA may be reached in pulse conditions. DX8200A
USER INTERFACE Vext 30 Vdc max
+
-
Figure 14 – Output 1 and Output 2 Interface
When the load is powered by an external power supply, the voltage must not exceed 30 V. OUT3 has different electrical features, since it is a bi-directional solid state relay with built-in current limit protection. If this output is continuously driven, the maximum current must not be more than 200 mA although more than 300 mA may be reached in pulse conditions for an ambient temperature of 25°C. At the maximum ambient temperature of 50°C the maximum respective current is 150 mA continuous and 240 mA pulse.
16
Page 33
INSTALLATION
2
The OUT3 electrical features are given below: Maximum voltage ± 100 V Collector current (pulse) 240 mA Max. Collector current (continuous) 150 mA Max. R on 6 – 15 Ω R off > 500 Ω Off-state leakage current < 1 µA Maximum power dissipation 550 mW at 50°C (Ambient temperature). DX8200A
USER INTERFACE Vext 100 Vdc max
A/B
B/A
Figure 15 – Output 3 Interface
The command signal is filtered and generates a delay of about 50 µs for OUT1 and OUT2 and 1 ms for OUT3.
2.3.2
Lonworks Input/Output Connector 1 A1
A2 15
INPUT (male)
scanner side external view
15 A1
1
A2
OUTPUT (female)
Figure 16 - Lonworks INPUT/OUTPUT Connectors
The following pinout is valid for the INPUT connector as well as for the OUTPUT connector.
Pin A1 A2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Lonworks INPUT/OUTPUT 17-pin Connector Pinout Name Function GND supply voltage (negative pin) VS supply voltage 20 to 30 vdc (positive pin) CHASSIS Cable shield A – internally connected by capacitor to chassis n.c. Not connected CHASSIS Cable shield B – internally connected by capacitor to chassis n.c. Not connected n.c. Not connected n.c. Not connected VS_I/O Supply voltage of I/O circuit Lon A+ Lonworks a line (positive pin) Lon ALonworks a line (negative pin) Lon B+ Lonworks b line (positive pin) Lon BLonworks b line (negative pin) SYS_I/O System signal SYS_ENC_I/O System signal Reserved Internally connected Ref_I/O Reference voltage of I/O circuit 17
Page 34
DX8200A
2
Network Termination When building a Lonworks system the network must be properly terminated by positioning the BTK-8102 Lonworks terminator in the DX8200A master reader and the BTK-8100 Lonworks bus return in the last DX8200A slave reader. The BTK-8100 bus return provides a connector to be inserted in the Lonworks 17-pin female connector of the last slave reader in the network; while the BTK-8102 Lonworks terminator provides a different connector to be inserted in the Lonworks 17-pin male connector of the master reader: DX8200A Master
DX8200A Last Slave BTK-8100
BTK-8102
CAB-810X Network CAB-810X Figure 17 - BTK-8102 and BTK-8100
Two cables are also provided as accessories to terminate and power the network: CAB-8605 and CAB-8305. CAB-8605 is a power and Lonworks termination cable to be used for connecting the DX8200A master to an external power unit within the network; while CAB-8305 is a power and bus return cable to be used for connecting the last DX8200A slave to an external power unit. These two cables must only be used for VDC models. DX8200A Master
DX8200A Last Slave
Network
Power Unit
CAB-8605 Figure 18 – CAB-8605 and CAB-8305
18
CAB-8305
Page 35
INSTALLATION
2
Lonworks Interface The Lonworks network is used for both input and output connection to build a multi-sided or omni-station system connecting several readers. The DX8200A master usually employs the 17-pin female connector for output connection to the first slave, while the 17-pin male connector is terminated by inserting the BTK-8102 terminator (see Figure 17 for details). Both connectors are always employed when connecting together the slave readers. In particular, the 17-pin female connector is used for output connection and the male one for input connection. The female connector in the last slave reader is terminated by the BTK-8100 bus return to close the system network. The following diagram represents the connection between a DX8200A working as master and a DX8200A working as a slave reader. The cable shields for LON A/B are connected to pin 1 and pin 3 - CHASSIS. Master
Slave
VS_I/O
12
12
13
13
15
15
CHASSIS
1
1
LON A+
8
8
LON A-
9
9
LON B+
10
10
LON B-
11
11
CHASSIS
3
3
VS
A1
AWG 13
A1
A2
AWG 13
A2
REF_I/O
GND
CHASSIS
CHASSIS
= male connector = female connector
Figure 19 – DX8200A Master/Slave Lonworks Connection
19
Page 36
DX8200A
2
The following diagrams represent different network terminations using either the BTK-8102 Lonworks terminator or the BTK-8100 bus return. In Figure 21 the BTK-8102 terminator is indicated by the element, while the figure below shows its electrical circuit in details:
Figure 20 – BTK-8102 Electrical Circuit
The diagram below represents the termination of the double Lonworks line of a DX8200A working as master by means of the BTK-8102. BTK-8102
Master VS
A2
A2
VS_I/O
7
7
LON A+
8
8
LON A-
9
9
LON B+
10
10
LON B-
11
11
GND
A1
A1
REF_I/O
15
15
T
T
= male connector = female connector
Figure 21 – DX8200A Master Termination
The diagram below represents the Lonworks bus return of a DX8200A working as slave by means of the BTK-8100. Last Slave
BTK-8100 1
1
LON A+
8
8
LON A-
9
9
LON B+
10
10
LON B-
11
11
3
3
Shields
= male connector = female connector
Figure 22 – DX8200A Lonworks Bus Return
20
Page 37
INSTALLATION
2.3.3
2
Ethernet Connector
This connector is only available for DX8200A Ethernet models and allows the Ethernet connection between the host and the reader.
Figure 23 – Harting RJ Industrial® Push Pull Male Connector
1
8
Figure 24 – DX8200A Harting RJ Industrial® Female Connector
This interface and the connector pinout (see the following table) are IEEE 802.3 10 BaseT and IEEE 802.3u 100 Base Tx compliant. RJ45 Modular Jack Pinout Pin 1 2 3 6 4, 5, 7, 8
Name TX + TX RX + RX N.C.
Function Transmitted data (+) Transmitted data (-) Received data (+) Received data (-) Not connected
In order to meet EMC requirements: • use Eth shielded cable
• connect the Ethernet interface cable shield to the plant earth ground
A ferrite (type Stewart 28A2029-0A0) must be applied on the scanner side of the Ethernet cable to reduce electrical noise. The cable shield must also be connected to the chassis of both connectors. NOTE
21
Page 38
DX8200A
2
Ethernet Interface The Ethernet interface (NIC) can be used for TCP/IP communication with a remote or local host computer by connecting the scanner to a LAN. It can also be connected directly to a host PC. The following is an example of a connection to a LAN through a Hub using a straight through cable: HUB / SWITCH
DX8200A TX+
1
1
TX-
2
2
RX+
3
3 n. c.
4
4 n. c.
5
5
RX-
6
6 n. c.
7
7 n. c.
8
8 n. c. = not connected
Figure 25 – Straight Through Cable
The following is an example of direct connection to a PC using an inverted cable: HOST PC
DX8200A TX+
1
3
TX-
2
6
RX+
3
1 n. c.
4
4 n. c.
5
5
RX-
6
2 n. c.
7
7 n. c.
8
8 n. c. = not connected
Figure 26 – Inverted Cable
For further details refer to the “Ethernet.pdf” document provided as reference documentation.