Page 21

INSTALLATION

2

2 INSTALLATION To install the system follow the given procedure: 1. Select the mounting location for DX8200A; 2. Mount the DX8200A scanner; 3. Position the scanner with respect to the barcode; 4. Proceed with system electrical connection; 5. Install the Genius™ program on the PC and configure the scanner.

WARNING

When installing several scanners, take care to position them correctly so that no laser beam enters the reading window perpendicularly and at the same level of the output beam of the other scanners. This condition could occur more frequently for side mounted applications. If these precautions are not followed, it may occur that the laser of the blinded scanner starts blinking due to an internal circuit which temporarily turns the laser off when detecting a power anomaly. To resolve this problem, it is sufficient to slightly change the inclination and position of one of the two scanners involved.

Refer to the Reference Documentation for details on connecting your DX8200A reader to other devices in the system (i.e. C-BOX 100 etc.). NOTE

2.1 PACKAGE CONTENTS Verify that the DX8200A reader and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes: • DX8200A reader • Installation Quick Reference + barcode test chart • DX8200A configuration CD-ROM

Figure 1 - DX8200A Package Contents

5

Page 22

DX8200A

2

2.2 MECHANICAL MOUNTING 2.2.1

Mounting the Scanner

DX8200A can be installed to operate in any position. There are 4 slots (dia. 8.5 mm) on the sides of the scanner for mounting. The diagram below can be used for installation; refer to par. 4.4 for correct positioning of the scanner with respect to the reading zone and scanner orientation. See par. "Scanner Direction" for scanner direction relative to the conveyor. PackTrack™ Coordinate Reference Point where x, y, z = 0 470 [18.50]

=

8.5 N° 4 [0.33]

180 [7.09] =

300 [11.81]

=

=

22 [0.87]

406 [15.98]

22 [0.87]

370 [14.57]

=

=

370 [14.57]

=

Figure 2- DX8200A Overall Dimensions

6

141 [5.55]

70.5 [2.78]

147 [5.79]

60.5 [2.38]

10 [0.39]

=

Page 23

INSTALLATION

2

2.3 ELECTRICAL CONNECTIONS All the connectors available for each scanner model are the following: Scanner Model Standard

Ethernet

Profibus

DeviceNet

Connectors 26-pin male serial interface and I/O connector 17-pin male Lonworks connector 17-pin female Lonworks connector 26-pin male serial interface and I/O connector 17-pin male Lonworks connector 17-pin female Lonworks connector RJ45 Industrial modular connector 26-pin male serial interface and I/O connector 17-pin male Lonworks connector 17-pin female Lonworks connector Profibus 9-pin female connector 26-pin male serial interface and I/O connector 17-pin male Lonworks connector 17-pin female Lonworks connector DeviceNet 5-pin male connector

7

Page 24

DX8200A

2

The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this pinout when the DX8200A reader is connected in a network by means of the C-BOX 100:

C-BOX 100 Terminal Block Connectors Power 1, 3, 5 2, 4, 6 7, 8 20, 40 27 28 29 30 31, 33 32, 34 36 21 22 23 24 25 26 35 37 38, 39

VS GND EARTH GROUND Reserved Inputs EXT TRIG/PS A (polarity insensitive) for PS EXT TRIG/PS B (polarity insensitive) for PS IN 2/ENC A (polarity insensitive) for Encoder IN 2/ENC B (polarity insensitive) for Encoder IN 3A (polarity insensitive) IN 4A (polarity insensitive) IN 3B/IN 4B Reference (polarity insensitive) Outputs OUT 1+ OUT 1OUT 2+ OUT 2OUT 3A (polarity insensitive) OUT 3B (polarity insensitive) Auxiliary Interface TX AUX RX AUX GND Main Interface RS485 RS485 RS232 Full-Duplex Half-Duplex TX232 TX485+ RTX485+ RTS232 TX485RTX485RX232 RX485+ CTS232 RX485-

11, 15 12, 16 17 18 10, 14, 19 SGND Main Isolated 9, 13

8

SGND Main Isolated RS485 Cable Shield

SGND Main Isolated RS485 Cable Shield

20 mA C.L. (with INT-30 only)

see INT-30 instructions

Page 25

INSTALLATION

2.3.1

2

Main/Aux. Serial Interface and I/O Connector

The DX8200A Standard and Fieldbus models are equipped with a 26-pin male D-sub connector for connection to the host computer, power supply and input/output signals. The details of the connector pins are indicated in the following table: 1 10 19

9 18

26

Figure 3 - 26-pin Connector

DX8200A 26-pin D-sub Connector Pinout Pin

Name

Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RXAUX Receive data of auxiliary RS232 (referred to GND) 21 TXAUX Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digital output 1 - positive pin 22 OUT 1Configurable digital output 1 - negative pin 11 OUT 2+ Configurable digital output 2 - positive pin 12 OUT 2Configurable digital output 2 - negative pin 16 OUT 3A Configurable digital output 3 - polarity insensitive 17 OUT 3B Configurable digital output 3 - polarity insensitive 18 EXT_TRIG/PS A External trigger (polarity insensitive) for PS 19 EXT_TRIG/PS B External trigger (polarity insensitive) for PS 6 IN 2/ENC A Input signal 2 (polarity insensitive) for Encoder 10 IN 2/ENC B Input signal 2 (polarity insensitive) for Encoder 14 IN 3A Input signal 3 (polarity insensitive) 15 IN 4A Input signal 4 (polarity insensitive) 24 IN_REF Common reference of IN3 and IN4 (polarity insensitive) 9,13 VS Supply voltage - positive pin 23,25,26 GND Supply voltage - negative pin Main Interface Connector Pinout RS485 RS485 20 mA C.L. Pin RS232 (INT-30 with C-BOX 100 only) Full Duplex Half Duplex 2 TX TX485 + RTX485 + 3 RX RX485 + 4 RTS TX485 RTX485 see INT-30 instructions 5 CTS RX485 7 GND_ISO GND_ISO GND_ISO

9

Page 26

DX8200A

2

Main Interface The main serial interface is compatible with the following electrical standards: RS232 RS485 half-duplex RS485 full-duplex (20 mA current loop) The 20 mA Current Loop interface is available by using the C-BOX 100 with the optional INT-30 accessory installed in it. The scanner communicates to the C-BOX 100 through the RS232 interface and the INT-30 converts the signals. The main serial interface type and its relative parameters (baud rate, data bits, etc.) are selected via software using the Genius™ utility program. For more details refer to the section "Main Serial Port" in the Genius™ Help On Line. Details regarding the connections and use of the main interface selection are given in the next paragraphs.

RS232 Interface The main serial interface is used for communication with the Host computer and allows both transmission of code data and configuring the reader. The overall maximum cable length should not exceed 15 m (50 ft). The following pins of the 26-pin connector are used for RS232 interface connection: Pin 2 3 4 5 7

Name TX RX RTS CTS GND-ISO

Function Transmit Receive Request to send Clear to send Main signal ground

The RTS and CTS signals control data transmission and synchronize the connected devices. If the RTS/CTS hardware protocol is enabled, the DX8200A activates the RTS output to indicate a message can be transmitted. The receiving unit must activate the CTS input to enable the transmission. DX8200A

USER INTERFACE 2

TX

3

RX

4

RTS

5

CTS

7

GND-ISO

1

CHASSIS

RXD TXD

SGND Main Isolated Earth Ground

Figure 4 - RS232 Connections

10

Page 27

INSTALLATION

2

RS485 Full-Duplex Interface The RS485 full-duplex interface is used for non-polled communication protocols in point-to-point connections over longer distances than those acceptable for RS232 communications or in electrically noisy environments. The overall maximum cable length should not exceed 1200 m (3937 ft). The following pins of the 26-pin connector are used for RS485 full-duplex interface connection: Pin 2 3 4 5 7

Name TX485 + RX485 + TX485 RX485 GND-ISO

Function RS485 output (+) RS485 input (+) RS485 output (-) RS485 input (-) Main signal ground

DX8200A

USER INTERFACE 2

TX485+

3

RX485+

4

TX485-

5

RX485-

7

GND_ISO

1

CHASSIS

RX485+ TX485+ RX485TX485SGND Main Isolated Earth Ground

Figure 5 - RS485 Full-Duplex Interface Connections

11

Page 28

DX8200A

2

RS485 Half-Duplex Interface The RS485 half-duplex interface can be used for multidrop connections with a Datalogic multiplexer or it can also be used for a master/slave layout. The overall maximum cable length should not exceed 1200 m (3937 ft). The following pins of the 26-pin connector are used for RS485 half-duplex interface connection: Pin 2 4 7

Name RTX485 + RTX485 GND-ISO

Function RS485 input/output (+) RS485 input/output (-) Main signal ground

DX8200A

MULTIPLEXER 2

RTX485+

4

RTX485-

7

GND_ISO

1

CHASSIS

RTX485+ RTX485RS485REF Earth Ground

Figure 6 – RS485 Half-Duplex Interface Connections

Auxiliary Interface The auxiliary serial interface is equipped with RS232 full-duplex interface connections. The interface type is exclusive and is selectable through the Genius™ configuration program. The overall maximum cable length should not exceed 15 m (50 ft). The following pins of the 26-pin connector are used for RS232 full-duplex interface connection: Pin 20 21 23

Name RXAUX TXAUX SGND AUX

Function Receive data Transmit data Auxiliary signal ground

DX8200A

USER INTERFACE 20

RXAUX

21

TXAUX

23

GNDAUX

1

CHASSIS

TXD RXD GND Earth Ground

Figure 7 - RS232 Auxiliary Interface Connections

12

Page 29

INSTALLATION

2

Inputs The inputs of the reader are on the 26-pin connector of the DX8200A. These inputs are called EXT_TRIG/PS, IN2/ENC, IN3 and IN4. Pin 18 19 6 10 14 15 24

Name EXT_TRIG/PS A EXT_TRIG/PS B IN2/ENC A IN2/ENC B IN3A IN4A IN_REF

Function External trigger (polarity insensitive) for PS External trigger (polarity insensitive) for PS Input signal 2 (polarity insensitive) for Encoder Input signal 2 (polarity insensitive) for Encoder Input signal 3 (polarity insensitive) Input signal 4 (polarity insensitive) Common reference of IN3 and IN4 (polarity insensitive)

IN2/ENC is normally used for the Encoder input. In PackTrack™ mode, it detects the conveyor speed. The maximum Encoder frequency is 2 KHz. EXT_TRIG/PS is the main presence sensor. When active, this input tells the scanner to scan for a code and that decoding can take place. The yellow LED (Figure C, 3) indicates the EXT_TRIG/PS is active. IN3 and IN4 can be used as the stop signal for the reading phase. All inputs are optocoupled, polarity insensitive, and driven by a constant current generator; the command signal is filtered through an anti-disturbance circuit which generates a delay which can be set to 5 ms or 500 µs. In particular, EXT_TRIG/PS, IN3 and IN4 share the same value which usually corresponds to 5 ms when using a photoelectric sensor, while IN2 has a different value which is set to 500 µs when this input is used for the Encoder. Vext

DX8200A

EXTERNAL TRIGGER/ENCODER V

A/B + 5V

~ + ~

-

B/A

Ground

Figure 8 – PNP Command Input Connection using External Power

DX8200A

EXTERNAL TRIGGER/ENCODER VS

V

A/B + 5V

~ + ~

-

B/A

Ground

GND

Figure 9 - PNP Command Input Connection using Scanner Power

13