A local Lonworks network allows logically connecting a DX8200A master reader with up to 31 DX8200A slaves. Actually, the maximum number of readers to be employed in the network depends on the system operating conditions; that is adopted operating mode and amount of data stream. When creating your network, always keep in mind the following guidelines: • the Lonworks network logically supports a maximum number of 32 devices (master + slaves);

• it is recommended to adhere to the 8-in-16 rule (not more than 8 devices in any 16 meter bus segment (branch);

• for DX8200A scanners the total bus length may extend up to 65 m (213 ft);

• the maximum number of DX8200A readers supported also depends on the type of power propagation adopted by the system (see the specific power supply installation manual for details).

Typically the layouts can be divided into Synchronized (single P.S.) or Multidata (multi P.S.) networks. They can be small (up to 10 scanners) or large (more than 10 scanners). Contact Datalogic S.p.A., if your network requires a higher number of readers or in case the application throughput is very high. For further information on Lonworks network cabling and connections see the “LonWorks® TPT Twisted Pair Transceiver Module User’s Guide”, available from the website: www.echelon.com.

CAUTION

32

For DX8200A Lonworks Network layouts, power is always propagated through the 17-pin scanner connectors. A special setting is required in C-BOX 100 to pass scanner power to the presence sensor, encoder, etc.

Page 49

INSTALLATION

2

Small Synchronized Network When building a small local Lonworks network (less than 10 scanners), the DX8200A master reader must be connected to a local host computer or a C-BOX 100 by means of a CAB-601X cable connected to the 26-pin D-sub male connector. The master reader connects to the first slave reader of the system through the local Lonworks 17-pin female connector. The local Lonworks 17-pin male connector must be properly terminated by inserting the BTK-8102 Lonworks terminator or be powered by the CAB-860X cable. The slave readers are connected together through the local Lonworks connectors. Only the 17-pin female connector of the last slave reader must be terminated by the BTK-8100 bus return or be powered by the CAB-830X cable. The presence sensor is connected and powered through the C-BOX 100 by the scanner and is unique to the system. There is only a single reading phase and a single message from the master reader to the Local Host. The On-Line operating mode is used for this layout. Master

BTK-8102

CAB601X C-BOX 100**

Slave 1 CAB810X P.S.* Local Host

CAB830X

*

PWR-120

P.S. (Presence Sensor) connected to External Trigger/PS input.

** C-BOX 100 modified to accept scanner power.

Figure 38 – Small Synchronized Network with 2 Readers

33

Page 50

DX8200A

2

The following image shows a system consisting of five readers where the external signals (trigger, encoder, serial to host, etc.) are connected to the master through the C-BOX 100. The system is powered by the PWR-240 where: • the master is connected through CAB-860X, which also provides bus termination

• the last slave is connected through CAB-830X, which also provides bus return.

• the master and all slaves are connected together through the CAB-810X cables CAB810X

CAB810X PWR-240

Slave 3

Slave 4

CAB830X CAB860X

C-BOX 100**

CAB601X CAB810X

Slave 2

P.S.* Encoder***

CAB810X

Slave 1

Master

*

P.S. (Presence Sensor) connected to External Trigger/PS input.

**

C-BOX 100 modified to accept scanner power.

***

Encoder connected to IN2/ENC input.

Local Host

Figure 39 – Small Synchronized Network with more than 2 Readers and Single Power Unit

34

Page 51

INSTALLATION

2

Large Synchronized Network When building a large local Lonworks network (more than 10 scanners), an SC6000 Controller must be used together with a PWO power supply/junction box unit. In this case the SC6000 unit acts as the system master and is connected to the host through one of its interfaces. All scanners act as slaves and are connected to the SC6000 through the PWO power supply/junction box. For DX8200A scanners, 4 branch connectors provide Lonworks communications between the scanners and the SC6000 unit. The last scanner on the line requires a Termination connector as well as any unused branches in the PWO unit. The allowed maximum bus length is 65 m. External devices such as a presence sensor and an encoder are all connected to the PWO. Host HUB ETHERNET

CAB-SC6103 Cable

SC6000

AUX

VAC INPUT

Power/Net CAB-SC6003 PWO

CAB-SC6003 Extended I/O LONWORKS ENC

BTK8100 Bus Return

CAB-810x

PS PS Aux

CAB-810x CAB-810x

CAB-810x up to 3 scanners per branch

DX8200A

DX8200A

BTK8100 Bus Return

DX8200A CAB-810X

CAB-810x

CAB-810x up to 4 scanners per branch

DS8100A

DS8100A

DS8100A

DS8100A

Figure 40 – Large Synchronized Network with DX8200A and DS8100A Scanners

35

Page 52

DX8200A

2

SC6000

Conveyor

Figure 41 - Large Synchronized Network Reading Station

36

Page 53

INSTALLATION

2

Redundant System For large local Lonworks networks, a redundant system can per configured in which two SC6000 Controllers are used together with their respective PWO power supply/junction box units. The scanners are distributed equally between the PWO units. In this case one of the SC6000 Controllers is dedicated as the working or active unit while the other functions as a dedicated protecting or backup unit. ETHERNET to Host

SC6000

VAC INPUT

CAB-SC6103 AUX

Working Controller

Power/Net CAB-SC6003

PWO

CAB-SC6003 Extended I/O LONWORKS ENCODER

CAB-810x

PS PS Aux

CAB-810X

CAB-810x

DS8100A

DS8100A

DX8200A

DX8200A

BTK8100

CAB-810x

Redundancy CAB-PWO 03

ETHERNET to Host

VAC INPUT SC6000 Power/Net CAB-SC6003

PWO

CAB-SC6003 Extended I/O

Protecting Controller

LONWORKS ENCODER

CAB-810x

CAB-810X

CAB-810x

DX8200A

PS PS Aux

DX8200A

CAB-810x

DS8100A

BTK8100

DS8100A

Figure 42 - Example Redundant Reading Station Layout

37

Page 54

DX8200A

2

Multidata Network In this layout, one master and up to 7 DX8200A slave readers have their own P.S. and therefore multiple reading phases. Each P.S. is connected through a C-BOX 100, which in turn is connected to its relative scanner through a CAB-601X cable. The master sends all the individual messages collected from the Lonworks interface as well as its own to the Local Host through its C-BOX 100. The following image shows a system consisting of four readers, which are all connected together using CAB-810X cables and the system is powered by a PWR-240 power supply. P.S.*

P.S.*

P.S.*

P.S.*

C-BOX 100** CAB810X

CAB810X

CAB810X

Local Host

CAB601X

Slave 3

Slave 2

Slave 1 CAB830X

*

Master PWR-240

P.S. (Presence Sensor) connected to External Trigger/PS input.

** all C-BOX 100s modified to accept scanner power

Figure 43 – Multidata Network

38

CAB860X

Page 55

INSTALLATION

2.5.6

2

Fieldbus Network

The Fieldbus models offer connectivity without any converter or adapter needed. The DX8200A master Fieldbus communicates with a remote host (for ex. remote PC connected via Internet) by means of a cable connected to the Fieldbus connector provided. It can be activated by a signal generated by the remote Host or by a physical presence sensor. The external signals (trigger, encoder) are connected to the master through the C-BOX 100. The system is powered by the PWR-240 where: • the master is connected through CAB-860X, which also provides bus termination

• the last slave is connected through CAB-830X, which also provides bus return.

• the master and all slaves are connected together through the CAB-810X cables

The same network layouts are available as for the DX8200A standard model.

CAB810X

CAB810X PWR-240

Slave 3

Slave 4

CAB830X CAB860X

C-BOX 100**

CAB601X CAB810X

P.S.* Encoder***

CAB810X

Fieldbus Network Slave 2

Slave 1

Master Remote Host

*

P.S. (Presence Sensor) connected to External Trigger/PS input.

**

C-BOX 100 modified to accept scanner power.

***

Encoder connected to IN2/ENC input.

Figure 44 – Fieldbus Small Synchronized Network

39

Page 56

DX8200A

2

2.6

KEYPAD AND DISPLAY

The DX8200A keypad allows entering a menu for selection of one of the following functions: • • • • • • •

Welcome: Autolearn:

shows the current software release and operating mode; starts the procedure making it possible to obtain an automatic, accurate and fast configuration of DX8200A without the necessity of directly checking/modifying the relevant parameters; Internal Net: defines scanner function within the network (see below); Ethernet Mode: allows setting the scanner IP address to be used within the network; LCD Contrast: sets the LCD contrast; Bus: allows setting the scanner address (value range 0-125) to be used in a Profibus network; Test Mode: allows verifying the scanner reading position and features (see below).

The same settings may be performed by using the Genius™ program (see chapter 3 for details).

2.6.1

Internal Net

This submenu can be used as an alternative to configuration through Genius™, to assign the DX8200A scanner within a master/slave network. It allows defining the scanner function (slave/master) within the network and, if configured as Slave, its address. To enter the Internal Net submenu and configure the scanner follow the given procedure: 1) Press and hold both the ▲ (up arrow) and ▼ (down arrow) keys for about 2 seconds to enter the Main menu; 2) Use the ▲ (up arrow) or ▼ (down arrow) key to select the “Internal Net” item, then press the ENT (enter) key to confirm; 3) Use the ▲ (up arrow) or ▼ (down arrow) key to select the “LonWAddrSel”” item, then press the ENT (enter) key to confirm; 4) Use the ▲ (up arrow) or ▼ (down arrow) key to select your scanner function among “Master”, “Slave n”, “Slave jolly”, “Disabled”; then, press the ENT (enter) key to confirm; 5) Use the ▲ (up arrow) or ▼ (down arrow) key to select the “Exit” item, then press the ENT (enter) key to confirm. Repeat this step again to exit the Main Menu and return to the scanner current operating mode.

2.6.2

Test Mode

Test Mode is particularly advised during the installation phase, since it causes the reader to be continuously activated allowing to verify its reading features and its reading position with respect to the barcode. To enter the Test Mode submenu and configure the scanner follow the given procedure: 1) Press and hold both the ▲ (up arrow) and ▼ (down arrow) keys for about 2 seconds to enter the Main menu. 2) Use the ▲ (up arrow) or ▼ (down arrow) key to select the “Test Mode” item, then press the ENT (enter) key to confirm. The reader enters Test Mode. 3) Press the ▲ (up arrow) key to exit the Test Mode. 4) Use the ▲ (up arrow) and ▼ (down arrow) key to select the “Exit” item, then press the ENT (enter) key to confirm. The scanner exits the Main Menu and returns to its current operating mode. 40