DX8200A Reference Manual: SOFTWARE CONFIGURATION
Pages 57 to 69 of 97, from DX8200A Reference Manual
The original document is the PDF (6.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Datalogic DX8200
Page 57
SOFTWARE CONFIGURATION
3
3 SOFTWARE CONFIGURATION 3.1 GENIUS™ INSTALLATION Genius™ is a new Datalogic scanner configuration tool providing several important advantages: • Wizard approach for low skilled users; • Multi-language version; • Defined configuration directly stored in the reader; • Communication protocol independent from the physical interface allowing to consider the reader as a remote object to be configured and monitored. To install Genius™, proceed as follows: 1) Turn on the PC that will be used for configuration, running either Windows 98, 2000/NT, or XP; 2) Insert the Genius™ CD-ROM; 3) Wait for the CD to autorun and follow the installation procedure.
3.2 GUIDE TO RAPID CONFIGURATION 3.2.1
Wizard for Quick Reader Setup
After installing the Genius™ software program (see par. 3.1) the following window appears asking the user to choose the desired configuration level:
Figure 45 - Genius™ Wizard Opening Window
The Wizard option is advised for low skilled users, since it shows a step-by-step scanner configuration. The parameters to be defined are the following: - Barcode selection and definition; - Operating mode selection and definition (see sub-paragraphs for further details); - Digital Inputs/Outputs configuration; - Hardware interface selection; - Output data format configuration.
41
Page 58
DX8200A
3
After defining the parameter values the following window appears allowing to complete the reader configuration as follows: -
Saving the configuration to disk;
-
Switching to Advanced mode;
-
Sending the configuration to the scanner.
Figure 46 - Genius™ Wizard Closing Window
Test Operating Mode
This operating mode is not available when DX8200A works as Slave. NOTE
Figure 47 - Test Mode Selection
This operating mode causes the reader to be continuously activated allowing to verify its reading features and its reading position with respect to the barcode. For this reason, it is particularly advised during the installation phase of the reader. After 100 scans, the values relative to an internal counter and the decoded code are displayed and transmitted on the serial interface. The counter reports the percentage of good reads of the label.
42
Page 59
SOFTWARE CONFIGURATION
3
On Line Operating Mode
Figure 48 - On Line Mode Selection
This operating mode causes the reader to be connected to an external Presence Sensor using EXT TRIG/PS A and EXT TRIG/PS B inputs. During the active phase of the presence sensor, the DX8200A reader tries to acquire and correctly decode the code. In case the decoding phase is successful, the barcode characters are transmitted on the serial interface. Otherwise, a no read message is sent.
Automatic Operating Mode
Figure 49 - Automatic Mode Selection
This operating mode does not require the connection to an external Presence Sensor. When working in this mode the reader is continuously scanning. The reading phase is activated each time a barcode enters the reading zone. The reader stops reading after an N number of scans without a code. Barcode characters are transmitted on the serial interface. In case of a failed reading phase no message is sent to the host computer.
43
Page 60
DX8200A
3
3.2.2
Genius™ Network Setup Through Master
Network Setup allows configuring your Local Lonworks Network through the Master using Genius™. Three different procedures are available to define the number of network slave scanners, their label and address according to two main conditions: Condition
Available Procedure
Feature
Unknown Slave Addresses
Net-Autoset automatically assigns random addresses to slave or Stand Alone scanners.
Known Slave Addresses
Network Wizard customizes the network (slave label and address definition and physical identification of a specific slave within network), updates configuration to a file and makes it ready to be sent to the Master.
Express Network Setup automatically performs all the operations of the Network Wizard apart from the physical identification of a specific slave scanner.
The Network Setup procedure as described requires Genius™ software version 1.06 or later. In addition, the Net-Autoset procedure requires scanner software version 6.40 or later. NOTE
1. The first operation to perform is the configuration of your scanner as "Master" from the Local Device Network Settings item in the Device Menu, see figure below:
Figure 50 – Local Device Network Settings
44
Page 61
SOFTWARE CONFIGURATION
3
The following dialog box appears asking whether to send the configuration to the Master or not:
icon available on the Toolbar to make the 2. Click the "Yes" button, then click on the “Devices” area appear next to the Parameter Explorer window. By repeatedly clicking the icon this area will be displayed or hidden.
Figure 51 – Cluster Configuration
Each scanner of the cluster is indicated by the following graphical objects:
• • • check box allowing to select/deselect a specific scanner to perform the desired operations (i.e. program downloading); icon representing the scanner status; a label reporting information transmitted by the scanner when connected (the scanner address, generated errors, scanner description).
45
Page 62
DX8200A
3
3. Then, proceed with the network setup by using one of the icons available on the Tool Bar according to the procedure to follow: =
Net-Autoset procedure
=
Network Wizard procedure
=
Express Network Setup procedure
Net-Autoset This procedure is to be used when all scanner addresses and labels are unknown (typically when configuring the network for the first time or whenever a network reconfiguration is required). By clicking the icon or selecting the "Net_Autoset" option from the right-click menu, the Net-Autoset procedure is started allowing automatic assignment of random addresses to all slave or Stand Alone scanners connected within the network. Once the procedure has been completed, it is possible to: • define customized addresses and labels through the Network Wizard;
• display the scanner default labels through the Express Network Setup.
Express Network Setup Before performing this procedure, a Lonworks address must be assigned to each slave scanner. The most practical method is through the Net-Autoset procedure. See par. 3.2.3 for alternative address assignment methods. Once all addresses have been assigned, the Express Network Setup is to be used when all scanner addresses and labels do not need to be modified. By clicking on the icon or by choosing the related option from the right-click menu, the procedure is started which automatically performs the following operations: - opening the wizard;
- polling the network to discover connected scanners;
- transferring all scanners found to the "Requested Devices" area of the wizard where your network customization is defined;
- saving the new network configuration;
Once the procedure has been completed, a dialog box will appear asking whether to send the configuration to the Master. Choose the “Yes” option to start this procedure.
46
Page 63
SOFTWARE CONFIGURATION
3
Network Wizard Before performing this procedure, a Lonworks address must be assigned to each slave scanner. The most practical method is through the Net-Autoset procedure. See par. 3.2.3 for alternative address assignment methods. Once all addresses have been assigned, the Network Wizard is to be used when one or more scanner addresses and labels need to be modified. 1. Click on the button to open the Network Wizard dialog box:
a. if the slave scanners have already been configured and wired to the network, click on the Autodetect button to start a polling procedure of the current network. All slave scanners found will be represented in the “Current Devices” area. Then, select the desired slave scanner from the “Current Devices” area and click on the icon (or drag and drop) to transfer it to the “Requested Devices” area where your network customization is defined. The following dialog box will appear allowing (if necessary) to change the slave address ("Available Device" field) and label ("Description" field):
b. if the slave scanners have not been configured and wired to the network, click on the icon to add a new device defining its address and model. The added slave scanner will be displayed in the “Requested Devices” area. This option in any case requires that all slave scanners have their address set before the network can function. 47
Page 64
DX8200A
3
2. If desired, select a slave scanner within the "Current Devices" area and click on the icon (or select the "Show Device" option from the right-click menu) to make the dialog box appear as follows:
• •
The "Show Device" option is particularly useful after the Net-Autoset procedure or whenever it is necessary to know which address is assigned to a specific slave scanner. Indeed, it activates the following signals which physically indicate the scanner corresponding to the one selected, in particular: in Network Wizard the icon corresponding to the selected slave scanner starts blinking red; in the Physical Network all slave scanner lasers turn off except the one of the selected scanner which turns on.
3. If desired, select the transferred/added slave scanner within the “Requested Devices” area and click on the icon to customize the scanner label and address.
4. Once your network has been customized, close the network wizard. Before closure, the program will show a dialog box asking whether to send the new configuration to the Master. Choose the “Yes” option to start this procedure.
48
Page 65
SOFTWARE CONFIGURATION
3.2.3
3
Alternative Slave Address Assignment
As alternatives to Network Setup through the Master, each Slave scanner can be assigned an address through the following methods: • address setting through the Local Device Network Settings item in the Device Menu with the slave scanner connected to Genius™
• manual address setting through slave scanner keyboard (see par. 2.6.1 for details)
3.3 ADVANCED GENIUS™ CONFIGURATION The ADVANCED selection available when starting the Genius™ program is addressed to expert users being able to complete a detailed scanner configuration. By choosing this option it is possible either to start a new scanner configuration or to open and modify an old one. The desired parameters can be defined in the following window, similar to the MS Explorer:
Figure 52 - Genius™ Parameter Explorer Window
The procedure for setting the scanner parameters is supported by an help on-line, which is displayed in an HTML browser. It can be selected from the Configuration Help option available in the Help menu. In addition, a context-sensitive help can be enabled by pressing the <F1> key after selecting the desired parameter.
49
Page 66
DX8200A
3
3.4 PARAMETER DEFAULT VALUES The following table contains the list of the factory default settings for the DX8200A. Genius™ also allows checking the parameter default values by selecting the "Compare parameters" option available in the Tools menu and comparing the current scanner configuration to the default one. Parameter Code Definition Code Combination No read Message No Read String Multiple Read Filters Code Label Settings #1 Code Symbology Label Length Min Code Position Max Code Position Check Digit Decoding Safety Decoding Severity Match String Rule Pattern Match String Match Direction Rule Code Label Settings #2 Code Symbology Label Length Minimum Label Length Maximum Label Length Min Code Position Max Code Position Check Digit Decoding Safety Decoding Severity Match String Rule Pattern Match String Match Direction Rule Operating Modes Operating Mode Selection On Line Options Start Input Number Start Input Active Level Reading Phase Timeout Verifier Reading System Layout Device Assignment Modify&Backup Lon Slave Configuration Enable A.S.R. 50
Default Setting Single Label Global No Read Message <CAN> Disabled (unchecked) Interleaved 2 of 5 8 0 255 Disabled (unchecked) 1 3 Match Empty Disable Code 39 Variable 1 60 0 255 Disabled (unchecked) 1 3 Match Empty Disable On Line On Line 1 Input 1 Active Closed Disabled (unchecked) Disabled (unchecked) Alone Disabled (unchecked) Disabled (unchecked)
Page 67
SOFTWARE CONFIGURATION
Parameter Reading Parameters Beam Shutter Overflow Start Ratio Overflow Stop Ratio Reading Mode Reading Condition Reconstruction Parameters Enabled Stacked Code Extended Min Match Position Tolerance Duration Tolerance Min Start/Stop Number Inter Char Gap Addon Overflow Ratio Scan Line Amplitude Amplitude Settings Enable PackTrack Calibration Direction PS Offset Data Communication Settings Host Application Protocol Type Data Format Header TX Start Termination After No Read Message Message Tx Trigger Selection Format Type Tx Max Delay After Phase Off Code Identifier Parameters Header String Code Position Code Direction Identifier Enable Termination String Data Packet Separators Code Field Length Setting Main Serial Port Data Tx Heartbeat Parameters Main Port Communication Mode Main Port Electrical Interface Handshake Baud Rate Parity Data Bits
3 Default Setting Disabled 5 5 Reconstruction Standard Disabled (unchecked) 0 50 50 2 8 2 Disabled (unchecked) 0 (Forward) 0 Standard With data Enabled (checked) On Decoding Standard Disabled Disabled <STX> Disabled (unchecked) Disabled (unchecked) <CR><LF> <CR><LF> Variable Length Enabled (checked) Disable Standard RS232 None 9600 None 8 51
Page 68
3 Default Setting Parameter Parameters Stop Bits 1 Auxiliary Serial Port Data Tx Enabled (checked) Heartbeat Disable Pass Through Disabled (unchecked) Parameters Baud Rate 115200 Parity None Data Bits 8 Stop Bits 1 Digital I/O Setting Digital Input Lines Setting Debouncing For Input 1, 3 and 4 5ms Debouncing For Input 2 500 µs Input 1 Active Level Overridden by Op. Mode Active Closed Input 2 Active Level Overridden by Op. Mode Active Closed Input 3 Active Level Overridden by Op. Mode Active Closed Input 4 Active Level Overridden by Op. Mode Active Closed Output 1 Line State Normally Open Activation Event Complete Read Alternative Activation Event Wrong Deactivation Event Timeout Alternative Deactivation Event None Deactivation Timeout (ms) 50 Output 2 Line State Normally Open Activation Event No Read Alternative Activation Event Partial Read Deactivation Event Timeout Alternative Deactivation Event None Deactivation Timeout (ms) 50 Output 3 Line State Normally Open Activation Event None Alternative Activation Event None Deactivation Event None Alternative Deactivation Event None System Information Section User Information Section End User Name Empty Device Name Empty Line Name Empty
52
DX8200A
Page 69
SOFTWARE CONFIGURATION
Parameter Diagnostics PackTrack Debug Message Tx Enable Statistics
3 Default Setting Disabled (unchecked) Unchecked Disabled (unchecked)
53