Page 10
DX8200A QUICK GUIDE Local Lonworks Networks Host HUB ETHERNET
CAB-SC6103 Cable
SC6000
AUX
VAC INPUT
Power/Net CAB-SC6003 PWO
CAB-SC6003 Extended I/O LONWORKS ENCODER
BTK8100 Bus Return
CAB-810x
PS PS Aux
CAB-810x CAB-810x
CAB-810x up to 3 scanners per branch
DX8200A
DX8200A
BTK8100 Bus Return
DX8200A CAB-810X
CAB-810x
CAB-810x up to 4 scanners per branch
DS8100A
DS8100A
DS8100A
Large Synchronized Network with DX8200A and DS8100A Scanners
SC6000
Conveyor
Large Synchronized Network Reading Station
10
DS8100A
Page 11
DX8200A QUICK GUIDE
COMMON FEATURES C-BOX 100 Pinout for DX8200A: The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this pinout when the DX8200A reader is connected in a network by means of the C-BOX 100: C-BOX 100 Terminal Block Connectors Power 1, 3, 5 2, 4, 6 7, 8 20, 40
VS GND EARTH GROUND Reserved Inputs
27 28 29 30 31, 33 32, 34 36
EXT TRIG/PS A (polarity insensitive) for PS EXT TRIG/PS B (polarity insensitive) for PS IN 2/ENC A (polarity insensitive) for Encoder IN 2/ENC B (polarity insensitive) for Encoder IN 3A (polarity insensitive) IN 4A (polarity insensitive) IN 3B/IN 4B Reference (polarity insensitive) Outputs
21 22 23 24 25 26
OUT 1+ OUT 1OUT 2+ OUT 2OUT 3A (polarity insensitive) OUT 3B (polarity insensitive) Auxiliary Interface
35 37 38, 39
TX AUX RX AUX GND Main Interface
11, 15 12, 16 17 18 10, 14, 19 9, 13
RS232
RS485 Full-Duplex
RS485 Half-Duplex
TX 232 RTS 232 RX 232 CTS 232 SGND Main Isolated
TX 485+ TX 485RX 485+ RX 485SGND Main Isolated RS485 Cable Shield
RTX 485+ RTX 485-
20 mA C.L. (with INT-30 only)
see INT-30 instructions SGND Main Isolated RS485 Cable Shield
11
Page 12
DX8200A QUICK GUIDE
Mechanical Installation: DX8200A can be installed to operate in any position. There are 4 slots (dia. 8.5 mm) on the sides of the scanner for mounting. The diagram below can be used for installation; refer to the Reading Diagrams for correct positioning of the scanner with respect to the reading zone and scanner orientation. PackTrack™ Coordinate Reference Point where x, y, z = 0 470 [18.50]
=
8.5 N° 4 [0.33]
=
180 [7.09]
300 [11.81]
=
=
22 [0.87]
406 [15.98]
22 [0.87]
370 [14.57]
=
=
370 [14.57]
=
141 [5.55]
70.5 [2.78]
147 [5.79]
60.5 [2.38]
10 [0.39]
=
DX8200A Overall Dimensions
WARNING
When installing several scanners, take care to position them correctly so that no laser beam enters the reading window perpendicularly and at the same level of the output beam of the other scanners. This condition could occur more frequently for side mounted applications. If these precautions are not followed, it may occur that the laser of the blinded scanner starts blinking due to an internal circuit which temporarily turns the laser off when detecting a power anomaly. To resolve this problem, it is sufficient to slightly change the inclination and position of one of the two scanners involved.
Reading Conditions: •
ANSI Grade B minimum
•
500 scans/sec per leg
The following tables describe the requirements for standard applications. Minimum Code Height for Omnidirectional Reading (mm) 0.5 1 1.5 2 0.25 11 13 15 17 0.30 12 14 16 18 0.33 13 15 17 19 2/5 Interleaved 0.38 14 16 18 20 Code Resolution (mm) 0.50 18 19 22 24 0.72 24 26 27 29 1.00 33 34 35 37
Conveyor Speed (m/s)
Ratio 3:1 Table 1
12
2.5 19 20 21 23 26 32 39
3 21 23 23 25 28 34 41
Page 13
DX8200A QUICK GUIDE Minimum Code Height for Omnidirectional Reading (mm) 0.5 1 1.5 2 0.25 9 11 13 15 0.30 10 11 14 16 0.33 11 12 14 16 Code 39 0.38 12 13 15 17 Code Resolution (mm) 0.50 15 16 17 19 0.72 20 22 23 24 1.00 27 28 29 30
Conveyor Speed (m/s)
2.5 17 18 18 19 21 25 32
3 19 20 20 21 23 27 33
2.5 16 17 18 18 20 24 28
3 18 19 20 20 22 26 30
2.5 16 17 18 18 20 24 28
3 18 19 20 20 22 26 30
2.5 15 16 16 17 19 21 26
3 18 18 19 19 21 23 27
Ratio 3:1; Interdigit = Module Size Table 2
Minimum Code Height for Omnidirectional Reading (mm) 0.5 1 1.5 2 0.25 8 10 12 14 0.30 9 11 13 15 0.33 9 11 13 15 Code 128 – Ean 128 0.38 10 12 14 16 Code Resolution (mm) 0.50 12 14 16 18 0.72 16 18 19 21 1.00 22 23 24 26
Conveyor Speed (m/s)
Table 3
Minimum Code Height for Omnidirectional Reading (mm) 0.5 1 1.5 2 0.25 8 10 12 14 0.30 9 11 13 15 0.33 9 11 13 15 Codabar 0.38 10 12 14 16 Code Resolution (mm) 0.50 13 14 16 18 0.72 17 18 19 21 1.00 23 24 25 26
Conveyor Speed (m/s)
Ratio 3:1; Interdigit = Module Size Table 4
Minimum Code Height for Omnidirectional Reading (mm) 0.5 1 1.5 2 0.25 8 9 11 13 0.30 9 10 12 14 0.33 9 10 12 14 EAN 8-13, UPC-A 0.38 10 11 13 15 Code Resolution (mm) 0.50 12 13 14 16 0.72 16 18 19 20 1.00 22 23 24 25
Conveyor Speed (m/s)
Table 5
13
Page 14
DX8200A QUICK GUIDE
Reading Diagrams: Note:
x = 0 and z = 0 correspond to the edge of the DX8200A scanner as shown in the figure below. DX8200A-3X3X (0.25 mm/10 mils)
z x
-20
-50
-16
-40
-12
-30
-8
-20
-4
-10
0
0
4
10
8
20
12
30
16
40
0
-16
-24
-32
-40
-48 (in)
0
-40
-60
-80
-100
-120
(cm)
50 20 (cm) (in)
CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90
DX8200A-3X2X (0.30 mm/12 mils)
z x
CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90
14
-24
-60
-20
-50
-16
-40
-12
-30
-8
-20
-4
-10
0
0
4
10
8
20
12
30
16
40
20
50
24
60
28 (in)
(cm)
70
0
-16
-24
-32
-40
-48
0
-40
-60
-80
-100
-120
-56 (in) -140
(cm)
Page 15
DX8200A QUICK GUIDE DX8200A-3X1X (0.38 mm/15 mils)
-28
-70
-24
-60
-20
-50
-16
-40
-12
-30
-8
-20
-4
-10
0
0
4
10
8
20
12
30
16
40
20
50
CONDITIONS
24
60
Code = Interleaved 2/5 or Code 39 PCS = 0.90
70 28 (in) (cm)
z x
0
-16
-24
-32
-40
-48
-56
-64 (in)
0
-40
-60
-80
-100
-120
-140
-160 (cm)
DX8200A-3X1X (0.50 mm/20 mils)
z x
CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90
-28
-70
-24
-60
-20
-50
-16
-40
-12
-30
-8
-20
-4
-10
0
0
4
10
8
20
12
30
16
40
20
50
24
60
0
-20
-24
-32
-40
-48
-56
-64
-72
(in)
0
-50 -60
-80
-100
-120
-140
-160
-180
(cm)
70 28 (in) (cm)
15
Page 16
DX8200A QUICK GUIDE
User Interface: How To Build A Simple Interface Test Cable: The following wiring diagram shows a simple test cable including power, external (push-button) trigger and PC RS232 COM port connections. 26-pin D-sub female
9-pin D-sub female
21
TXAUX
2
RX
20
RXAUX
3
TX
5
GND
23 GND
PC
13 VS 25 GND
DX8200A
9
VS
18 EXT TRIG A 19 EXT TRIG B
Power Supply VS (20 – 30 VDC) Power GND
Trigger
Compliance: Laser Safety
1 1
Figure A
Figure B
1 Warning and Device Class Label
1 Device Identification Label
The scanner is classified as a Class 2 laser product according to EN60825-1 regulations and as a Class II laser product according to CDRH regulations. Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light. There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed. The laser beam can be switched off through a software command (see also the Genius™ Help On-Line).
16
Page 17
DX8200A QUICK GUIDE
LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAXIMUM OUTPUT RADIATION 1 mW EMITTED WAVELENGTH 630~680 nm TO EN 60825-1:2001
DATALOGIC S.P.A. Via Candini, 2 40012 Calderara di Reno - Bologna - Italy
CAUTION-CLASS 3B LASER LIGHT WHEN OPEN AVOID EXPOSURE TO BEAM
LASER LIGHT EMITTED FROM THIS APERTURE
Manufactured
Volt
Model No.
Amp.
Serial No. This product conforms to the applicable requirements of 21CFR1040 at the date of manufacture.
Warning and Device Class Labels
The laser diodes used in this device are classified as Class 3B laser products according to EN 60825-1 regulations and as Class IIIb laser products according to CDRH regulations. As it is not possible to apply a classification label on the laser diodes used in this device, the following label is reproduced here:
Device Identification Label
LASER LIGHT AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODUCT MAXIMUM OUTPUT RADIATION 30 mW EMITTED WAVELENGTH 630~680 nm
Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode (30 mW at 630~680 nm).
TO EN 60825-1 (2001)
Laser Diode Class Label
Power Supply This product is intended to be installed by Qualified Personnel only. For DX8200A VDC models:
- This scanner is intended to be supplied by either a UL Listed power supply marked 'Class 2' or 'LPS', output rated 20 - 30 V dc, minimum 1.75 A or by a UL Listed computer with LPS outputs. - This scanner must be supplied by a Class II Power Supply Unit conforming to the EN 60950 safety regulation.
Line Fuse Replacement (VAC Models only) Caution - double pole/neutral fusing. For continued protection against risk of fire, replace with same type and rating of fuse (250V, 3.15 A). CAUTION
WEEE Compliance
17
Page 18
DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy
05 dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el DX8200A-XXXX, Laser Scanner e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: den nachstehenden angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente: 89/336/EEC EMC Directive e and et und y
92/31/EEC, 93/68/EEC emendamenti successivi further amendments ses successifs amendements späteren Abänderungen succesivas enmiendas
73/23/EEC Low Voltage Directive Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti. On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety. Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits. Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen. Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto. Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas: EN 55022 (Class A ITE), August 1994: Amendment A1 (Class A ITE), October 2000:
LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT
EN 61000-6-2, October 2001:
ELECTROMAGNETIC COMPATIBILITY (EMC) PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS
EN 60950-1, December 2001:
INFORMATION TECHNOLOGY EQUIPMENT - SAFETY – PART 1: GENERAL REQUIREMENTS
EN 60825-1, June 1994: Amendments A11 (1996), A2 (2001)
SAFETY OF LASER PRODUCTS – PART 1: EQUIPMENT CLASSIFICATION, REQUIREMENTS AND USER’S GUIDE
EN 61000-3-2, December 2000:
ELECTROMAGNETIC COMPATIBILITY (EMC) PART 3-2: LIMITS – LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT UP TO AND INCLUDING 16A PER PHASE
EN 61000-3-3, July 1995:
ELECTROMAGNETIC COMPATIBILITY (EMC) PART 3: LIMITS SECTION 3: LIMITATION OF VOLTAGE FLUCTUATIONS AND FLICKER IN LOW-VOLTAGE SUPPLY SYSTEMS FOR EQUIPMENT WITH RATED CURRENT ≤ 16A PART 1: EQUIPMENT CLASSIFICATION, REQUIREMENTS AND USER'S GUIDE
Lippo di Calderara, 08/09/2005 Ruggero Cacioppo Quality Assurance Laboratory Manager
821001201 (Rev. B)