Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 2

DX8200A Quick Guide, pages 10 to 18

Pages 10 to 18 of 18

The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Datalogic DX8200

Page 10

DX8200A QUICK GUIDE Local Lonworks Networks Host HUB ETHERNET

CAB-SC6103 Cable

SC6000

AUX

VAC INPUT

Power/Net CAB-SC6003 PWO

CAB-SC6003 Extended I/O LONWORKS ENCODER

BTK8100 Bus Return

CAB-810x

PS PS Aux

CAB-810x CAB-810x

CAB-810x up to 3 scanners per branch

DX8200A

DX8200A

BTK8100 Bus Return

DX8200A CAB-810X

CAB-810x

CAB-810x up to 4 scanners per branch

DS8100A

DS8100A

DS8100A

Large Synchronized Network with DX8200A and DS8100A Scanners

SC6000

Conveyor

Large Synchronized Network Reading Station

10

DS8100A

Page 11

DX8200A QUICK GUIDE

COMMON FEATURES C-BOX 100 Pinout for DX8200A: The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this pinout when the DX8200A reader is connected in a network by means of the C-BOX 100: C-BOX 100 Terminal Block Connectors Power 1, 3, 5 2, 4, 6 7, 8 20, 40

VS GND EARTH GROUND Reserved Inputs

27 28 29 30 31, 33 32, 34 36

EXT TRIG/PS A (polarity insensitive) for PS EXT TRIG/PS B (polarity insensitive) for PS IN 2/ENC A (polarity insensitive) for Encoder IN 2/ENC B (polarity insensitive) for Encoder IN 3A (polarity insensitive) IN 4A (polarity insensitive) IN 3B/IN 4B Reference (polarity insensitive) Outputs

21 22 23 24 25 26

OUT 1+ OUT 1OUT 2+ OUT 2OUT 3A (polarity insensitive) OUT 3B (polarity insensitive) Auxiliary Interface

35 37 38, 39

TX AUX RX AUX GND Main Interface

11, 15 12, 16 17 18 10, 14, 19 9, 13

RS232

RS485 Full-Duplex

RS485 Half-Duplex

TX 232 RTS 232 RX 232 CTS 232 SGND Main Isolated

TX 485+ TX 485RX 485+ RX 485SGND Main Isolated RS485 Cable Shield

RTX 485+ RTX 485-

20 mA C.L. (with INT-30 only)

see INT-30 instructions SGND Main Isolated RS485 Cable Shield

11

Page 12

DX8200A QUICK GUIDE

Mechanical Installation: DX8200A can be installed to operate in any position. There are 4 slots (dia. 8.5 mm) on the sides of the scanner for mounting. The diagram below can be used for installation; refer to the Reading Diagrams for correct positioning of the scanner with respect to the reading zone and scanner orientation. PackTrack™ Coordinate Reference Point where x, y, z = 0 470 [18.50]

=

8.5 N° 4 [0.33]

=

180 [7.09]

300 [11.81]

=

=

22 [0.87]

406 [15.98]

22 [0.87]

370 [14.57]

=

=

370 [14.57]

=

141 [5.55]

70.5 [2.78]

147 [5.79]

60.5 [2.38]

10 [0.39]

=

DX8200A Overall Dimensions

WARNING

When installing several scanners, take care to position them correctly so that no laser beam enters the reading window perpendicularly and at the same level of the output beam of the other scanners. This condition could occur more frequently for side mounted applications. If these precautions are not followed, it may occur that the laser of the blinded scanner starts blinking due to an internal circuit which temporarily turns the laser off when detecting a power anomaly. To resolve this problem, it is sufficient to slightly change the inclination and position of one of the two scanners involved.

Reading Conditions: •

ANSI Grade B minimum

•

500 scans/sec per leg

The following tables describe the requirements for standard applications. Minimum Code Height for Omnidirectional Reading (mm) 0.5 1 1.5 2 0.25 11 13 15 17 0.30 12 14 16 18 0.33 13 15 17 19 2/5 Interleaved 0.38 14 16 18 20 Code Resolution (mm) 0.50 18 19 22 24 0.72 24 26 27 29 1.00 33 34 35 37

Conveyor Speed (m/s)

Ratio 3:1 Table 1

12

2.5 19 20 21 23 26 32 39

3 21 23 23 25 28 34 41

Page 13

DX8200A QUICK GUIDE Minimum Code Height for Omnidirectional Reading (mm) 0.5 1 1.5 2 0.25 9 11 13 15 0.30 10 11 14 16 0.33 11 12 14 16 Code 39 0.38 12 13 15 17 Code Resolution (mm) 0.50 15 16 17 19 0.72 20 22 23 24 1.00 27 28 29 30

Conveyor Speed (m/s)

2.5 17 18 18 19 21 25 32

3 19 20 20 21 23 27 33

2.5 16 17 18 18 20 24 28

3 18 19 20 20 22 26 30

2.5 16 17 18 18 20 24 28

3 18 19 20 20 22 26 30

2.5 15 16 16 17 19 21 26

3 18 18 19 19 21 23 27

Ratio 3:1; Interdigit = Module Size Table 2

Minimum Code Height for Omnidirectional Reading (mm) 0.5 1 1.5 2 0.25 8 10 12 14 0.30 9 11 13 15 0.33 9 11 13 15 Code 128 – Ean 128 0.38 10 12 14 16 Code Resolution (mm) 0.50 12 14 16 18 0.72 16 18 19 21 1.00 22 23 24 26

Conveyor Speed (m/s)

Table 3

Minimum Code Height for Omnidirectional Reading (mm) 0.5 1 1.5 2 0.25 8 10 12 14 0.30 9 11 13 15 0.33 9 11 13 15 Codabar 0.38 10 12 14 16 Code Resolution (mm) 0.50 13 14 16 18 0.72 17 18 19 21 1.00 23 24 25 26

Conveyor Speed (m/s)

Ratio 3:1; Interdigit = Module Size Table 4

Minimum Code Height for Omnidirectional Reading (mm) 0.5 1 1.5 2 0.25 8 9 11 13 0.30 9 10 12 14 0.33 9 10 12 14 EAN 8-13, UPC-A 0.38 10 11 13 15 Code Resolution (mm) 0.50 12 13 14 16 0.72 16 18 19 20 1.00 22 23 24 25

Conveyor Speed (m/s)

Table 5

13

Page 14

DX8200A QUICK GUIDE

Reading Diagrams: Note:

x = 0 and z = 0 correspond to the edge of the DX8200A scanner as shown in the figure below. DX8200A-3X3X (0.25 mm/10 mils)

z x

-20

-50

-16

-40

-12

-30

-8

-20

-4

-10

0

0

4

10

8

20

12

30

16

40

0

-16

-24

-32

-40

-48 (in)

0

-40

-60

-80

-100

-120

(cm)

50 20 (cm) (in)

CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90

DX8200A-3X2X (0.30 mm/12 mils)

z x

CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90

14

-24

-60

-20

-50

-16

-40

-12

-30

-8

-20

-4

-10

0

0

4

10

8

20

12

30

16

40

20

50

24

60

28 (in)

(cm)

70

0

-16

-24

-32

-40

-48

0

-40

-60

-80

-100

-120

-56 (in) -140

(cm)

Page 15

DX8200A QUICK GUIDE DX8200A-3X1X (0.38 mm/15 mils)

-28

-70

-24

-60

-20

-50

-16

-40

-12

-30

-8

-20

-4

-10

0

0

4

10

8

20

12

30

16

40

20

50

CONDITIONS

24

60

Code = Interleaved 2/5 or Code 39 PCS = 0.90

70 28 (in) (cm)

z x

0

-16

-24

-32

-40

-48

-56

-64 (in)

0

-40

-60

-80

-100

-120

-140

-160 (cm)

DX8200A-3X1X (0.50 mm/20 mils)

z x

CONDITIONS Code = Interleaved 2/5 or Code 39 PCS = 0.90

-28

-70

-24

-60

-20

-50

-16

-40

-12

-30

-8

-20

-4

-10

0

0

4

10

8

20

12

30

16

40

20

50

24

60

0

-20

-24

-32

-40

-48

-56

-64

-72

(in)

0

-50 -60

-80

-100

-120

-140

-160

-180

(cm)

70 28 (in) (cm)

15

Page 16

DX8200A QUICK GUIDE

User Interface: How To Build A Simple Interface Test Cable: The following wiring diagram shows a simple test cable including power, external (push-button) trigger and PC RS232 COM port connections. 26-pin D-sub female

9-pin D-sub female

21

TXAUX

2

RX

20

RXAUX

3

TX

5

GND

23 GND

PC

13 VS 25 GND

DX8200A

9

VS

18 EXT TRIG A 19 EXT TRIG B

Power Supply VS (20 – 30 VDC) Power GND

Trigger

Compliance: Laser Safety

1 1

Figure A

Figure B

1 Warning and Device Class Label

1 Device Identification Label

The scanner is classified as a Class 2 laser product according to EN60825-1 regulations and as a Class II laser product according to CDRH regulations. Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to hazardous laser light. There is a safety device which allows the laser to be switched on only if the motor is rotating above the threshold for its correct scanning speed. The laser beam can be switched off through a software command (see also the Genius™ Help On-Line).

16

Page 17

DX8200A QUICK GUIDE

LASER LIGHT DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT MAXIMUM OUTPUT RADIATION 1 mW EMITTED WAVELENGTH 630~680 nm TO EN 60825-1:2001

DATALOGIC S.P.A. Via Candini, 2 40012 Calderara di Reno - Bologna - Italy

CAUTION-CLASS 3B LASER LIGHT WHEN OPEN AVOID EXPOSURE TO BEAM

LASER LIGHT EMITTED FROM THIS APERTURE

Manufactured

Volt

Model No.

Amp.

Serial No. This product conforms to the applicable requirements of 21CFR1040 at the date of manufacture.

Warning and Device Class Labels

The laser diodes used in this device are classified as Class 3B laser products according to EN 60825-1 regulations and as Class IIIb laser products according to CDRH regulations. As it is not possible to apply a classification label on the laser diodes used in this device, the following label is reproduced here:

Device Identification Label

LASER LIGHT AVOID EXPOSURE TO BEAM CLASS 3B LASER PRODUCT MAXIMUM OUTPUT RADIATION 30 mW EMITTED WAVELENGTH 630~680 nm

Any violation of the optic parts in particular can cause radiation up to the maximum level of the laser diode (30 mW at 630~680 nm).

TO EN 60825-1 (2001)

Laser Diode Class Label

Power Supply This product is intended to be installed by Qualified Personnel only. For DX8200A VDC models:

- This scanner is intended to be supplied by either a UL Listed power supply marked 'Class 2' or 'LPS', output rated 20 - 30 V dc, minimum 1.75 A or by a UL Listed computer with LPS outputs. - This scanner must be supplied by a Class II Power Supply Unit conforming to the EN 60950 safety regulation.

Line Fuse Replacement (VAC Models only) Caution - double pole/neutral fusing. For continued protection against risk of fire, replace with same type and rating of fuse (250V, 3.15 A). CAUTION

WEEE Compliance

17

Page 18

DATALOGIC S.p.A., Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy

05 dichiara che declares that the déclare que le bescheinigt, daß das Gerät declare que el DX8200A-XXXX, Laser Scanner e tutti i suoi modelli and all its models et tous ses modèles und seine Modelle y todos sus modelos sono conformi alle Direttive del Consiglio Europeo sottoelencate: are in conformity with the requirements of the European Council Directives listed below: sont conformes aux spécifications des Directives de l'Union Européenne ci-dessous: den nachstehenden angeführten Direktiven des Europäischen Rats: cumple con los requisitos de las Directivas del Consejo Europeo, según la lista siguiente: 89/336/EEC EMC Directive e and et und y

92/31/EEC, 93/68/EEC emendamenti successivi further amendments ses successifs amendements späteren Abänderungen succesivas enmiendas

73/23/EEC Low Voltage Directive Basate sulle legislazioni degli Stati membri in relazione alla compatibilità elettromagnetica ed alla sicurezza dei prodotti. On the approximation of the laws of Member States relating to electromagnetic compatibility and product safety. Basée sur la législation des Etats membres relative à la compatibilité électromagnétique et à la sécurité des produits. Über die Annäherung der Gesetze der Mitgliedsstaaten in bezug auf elektromagnetische Verträglichkeit und Produktsicherheit entsprechen. Basado en la aproximación de las leyes de los Países Miembros respecto a la compatibilidad electromagnética y las Medidas de seguridad relativas al producto. Questa dichiarazione è basata sulla conformità dei prodotti alle norme seguenti: This declaration is based upon compliance of the products to the following standards: Cette déclaration repose sur la conformité des produits aux normes suivantes: Diese Erklärung basiert darauf, daß das Produkt den folgenden Normen entspricht: Esta declaración se basa en el cumplimiento de los productos con las siguientes normas: EN 55022 (Class A ITE), August 1994: Amendment A1 (Class A ITE), October 2000:

LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT

EN 61000-6-2, October 2001:

ELECTROMAGNETIC COMPATIBILITY (EMC) PART 6-2: GENERIC STANDARDS - IMMUNITY FOR INDUSTRIAL ENVIRONMENTS

EN 60950-1, December 2001:

INFORMATION TECHNOLOGY EQUIPMENT - SAFETY – PART 1: GENERAL REQUIREMENTS

EN 60825-1, June 1994: Amendments A11 (1996), A2 (2001)

SAFETY OF LASER PRODUCTS – PART 1: EQUIPMENT CLASSIFICATION, REQUIREMENTS AND USER’S GUIDE

EN 61000-3-2, December 2000:

ELECTROMAGNETIC COMPATIBILITY (EMC) PART 3-2: LIMITS – LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT UP TO AND INCLUDING 16A PER PHASE

EN 61000-3-3, July 1995:

ELECTROMAGNETIC COMPATIBILITY (EMC) PART 3: LIMITS SECTION 3: LIMITATION OF VOLTAGE FLUCTUATIONS AND FLICKER IN LOW-VOLTAGE SUPPLY SYSTEMS FOR EQUIPMENT WITH RATED CURRENT ≤ 16A PART 1: EQUIPMENT CLASSIFICATION, REQUIREMENTS AND USER'S GUIDE

Lippo di Calderara, 08/09/2005 Ruggero Cacioppo Quality Assurance Laboratory Manager

821001201 (Rev. B)