The text of a manual · part 1 of 2
DX8200A Quick Guide, pages 1 to 9
Pages 1 to 9 of 18
The original document is the PDF (1.4 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Datalogic DX8200
Page 1
DX8200A QUICK GUIDE
DX8200A General View:
1
2 2 3
4 Figure A 1 Laser Beam Output Windows
2 Mounting Slots
3 Laser Safety Label
4 Mounting Reference Label
3 1 1
7
2 Standard
2
3
4
5
6
Figure B 1 Programming Keypad
5 TX Data LED (Green)
2 Power On LED (Green)
6 Network LED (Red)
3 Phase On LED (Yellow)
7 LCD Display
4
Ethernet
5
4 Encoder LED (Yellow)
Profibus
1
2
3
4 6
DeviceNet Figure C 1 Lonworks 17-pin Male Connector
Figure D (VAC Models Only)
2 Lonworks 17-pin Female Connector 3 Serial Interface and I/O 26-pin male Connector
1 Line Fuses
3 Power Inlet
4 Harting RJ Industrial® Modular female Connector
2 Line Switch
4 Cord Retaining Clamp
5 Profibus 9-pin female Connector 6 DeviceNet 5-pin male Connector
For further details on product installation, see the complete Reference Manual available on the configuration CD-ROM included with this product. NOTE
Page 2
DX8200A QUICK GUIDE
Technical Features: ELECTRICAL FEATURES Supply voltage Power consumption Common Communication Interfaces
Model-Dependent Communication Interfaces Inputs Ext. Trigger 1, 3 aux. digital inputs Outputs 3 software programmable digital outputs
VAC models VDC models 110 to 230 Vac 20 to 30 Vdc 30 VA typical 30 W typical 35 W Max. (including startup current) Baud Rate
Main RS232 RS485 full-duplex RS485 half-duplex 20 mA C.L. (INT-30 with C-BOX 100 only) Auxiliary RS232 Other Lonworks Ethernet Profibus DeviceNet
1200 to 115200 19200 1200 to 115200 1.25 Mb/s 100Mb/s up to 12 M/bs up to 500 K/bs
(optocoupled NPN or PNP)
(optocoupled)
OPTICAL FEATURES Light receiver Wavelength Safety class Light source Laser control
Avalanche photodiode 630 to 680 nm Class 2 - EN60825-1; Class II - CDRH Up to 4 semiconductor laser diodes Security system to turn laser off in case of motor slow down
READING FEATURES Scan rate Maximum resolution Max. reading distance Max. reading width Max. depth of field
≤ 1000 scans/s (500 per leg) (see reading diagrams on page 14)
USER INTERFACE LCD Display Keypad LED indicators
2
2 lines by 20 characters LCD 3 keys Power On (green) Phase On (yellow) Encoder (yellow) TX Data (green) Network (red)
Page 3
DX8200A QUICK GUIDE SOFTWARE FEATURES Readable Codes
Code selection Headers and Terminators Operating modes Configuration modes Parameter storage
Interleaved 2/5 Code 39 Standard Codabar Code 128 EAN 128 Code 93 (standard and full ASCII) EAN/UPC (including Add-on 2 and Add-on 5) Up to 10 codes during one reading phase Up to 128-bytes headers and 128-bytes terminators On Line, Serial On Line, Automatic, Test, PackTrack™, Continuous Genius™ utility program Non-volatile internal FLASH
ENVIRONMENTAL FEATURES Operating temperature Storage temperature Humidity Ambient light immunity Vibration resistance: EN 60068-2-6 2 hours on each axis Shock resistance: IEC 68-2-27 test EA 3 shocks on each axis Protection class
0° to +50 °C (+32° to +122 °F) -20° to +70 °C (-4° to +158 °F) 90% non condensing 20000 lux Frequency range from 5 to 150 Hz; Constant displacement 3 mm pk-pk from 5 to 9 Hz; Constant acceleration 0.5 g from 9 to 150 Hz; 30 g; 11 ms IP64*
PHYSICAL FEATURES Mechanical dimensions Weight
470 x 300 x 141 mm (18.50 x 11.81 x 5.55 in) about 11 kg (24 lbs. 3 oz.)
* sealed connectors required, use Harting RJ Industrial® Push Pull Ethernet connector for Ethernet models.
3
Page 4
DX8200A QUICK GUIDE
Model Description:
DX8200A - 3 X Y Z Power: 0 = VDC 1 = VAC Communication Type:
Optical Resolution:
0 = Standard version 1 = Ethernet version 2 = Profibus version 3 = DeviceNet version
1 = Medium resolution 2 = High resolution 3 = Very High resolution
Accessories: NAME PWR-120 PWR-240 PWR-480 BTK-8100 BTK-8102 PLL-8000 US-BOX FS-1 CAB-DX8000 CAB-DX8001 CAB-8100 CAB-8101 CAB-8102 CAB-8105 CAB-8305 CAB-8310 CAB-8402 CAB-8405 CAB-6011 CAB-6012 CAB-6015 CAB-6502 CAB-6505 CAB-8605 CAB-DX8000 CAB-DX8001 Sentinel-5 Sentinel-10 Sentinel-32 C-BOX 100 MEP-542 MEP-543 OEK-2 OEK-1 US-BOX UPT-80
4
Description J-box power unit 110/230 VAC 24 V 120 W J-box power unit 110/230 VAC 24 V 240 W J-box power unit 110/230 VAC 24 V 480 W Bus terminator kit (5 pcs) Double terminator kit (2 pcs) Optocoupled PLL device C-BOX mounting bracket to station frame (10 pcs) Frame shaper (8 pcs) DX8200A Power Cable VAC DX8200A Power Cable VAC (US) 10 wire shielded cable D 9.5 mm – 50 m 17-pin scanner/scanner connection cable 1.2 m 17-pin scanner/scanner connection cable 2.5 m 17-pin scanner/scanner connection cable 5 m Power and bus return cable (last Slave) 5 m Power and bus return cable (last Slave) 10 m No power cable 2.5 m No power cable 5 m 26-pin scanner to C-BOX 100 1 m 26-pin scanner to C-BOX 100 2 m 26-pin scanner to C-BOX 100 5 m Fam 6K-8K cross cable 2.5 m Fam 6K-8K cross cable 5 m Power and Lonworks termination cable (Master) 5 m Power cable DX8200A VAC (EU) Power cable DX8200A VAC (US) Supervisor (up to 5 arrays) Supervisor (up to 10 arrays) Supervisor (up to 32 arrays) Passive Connection Box Photocell kit – PNP Photocell kit – NPN Optical encoder kit (10 m cable + spring) Optical encoder kit + 10 m cable C-BOX Mounting Bracket to station frame (10 pcs) DX8200A – DX8200 Adapter
Part Number 93ACC1530 93ACC1070 93ACC1080 93ACC1090 93A051287 93ACC1280 93ACC1777 93ACC1750 93A051333 93A051334 93ACC1120 93A051020 93A051030 93A051040 93A051268 93A051336 93ACC1758 93ACC1759 93A051221 93A051222 93A051223 93A051288 93A051289 93A051290 93A051333 93A051334 93A101004 93A101005 93A101007 93ACC1510 93ACC1727 93ACC1728 93ACC1770 93ACC1600 93ACC1777 93ACC1757
Page 5
DX8200A QUICK GUIDE
Electrical Connections: The details of the connector pins are indicated in the following tables: The DX8200A scanner provides a 26-pin male D-sub connector for connection to power supply, Host interface (Main and Aux), and input/output signals. 26-pin D-Sub Connector Pinout Pin
Name
Function Chassis - internally connected to GND 1 CHASSIS Cable shield connected to chassis 20 RXAUX Receive data of auxiliary RS232 (referred to GND) 21 TXAUX Transmit data of auxiliary RS232 (referred to GND) 8 OUT 1+ Configurable digital output 1 – positive pin 22 OUT 1Configurable digital output 1 – negative pin 11 OUT 2+ Configurable digital output 2 – positive pin 12 OUT 2Configurable digital output 2 – negative pin 9 1 16 OUT 3A Configurable digital output 3 – polarity insensitive 10 18 17 OUT 3B Configurable digital output 3 – polarity insensitive 19 26 18 EXT_TRIG/PS A External trigger (polarity insensitive) for PS 26-pin male D-sub Connector 19 EXT_TRIG/PS B External trigger (polarity insensitive) for PS 6 IN2/ENC A Input signal 2 (polarity insensitive) for Encoder 10 IN2/ENC B Input signal 2 (polarity insensitive) for Encoder 14 IN3A Input signal 3 (polarity insensitive) 15 IN4A Input signal 4 (polarity insensitive) 24 IN_REF Common reference of IN3 and IN4 (polarity insensitive) 9, 13 VS Supply voltage – positive pin 23, 25, 26 GND Supply voltage – negative pin Main Interface Connector Pinout 20 mA C.L. Pin RS232 RS485 Full-Duplex RS485 Half-Duplex
(INT-30 with C-BOX 100 only)
2 3 4 5 7
TX RX RTS CTS GND_ISO
TX485+ RX485+ TX485RX485GND_ISO
RTX485+ see INT-30 instructions
RTX485GND_ISO
Two 17-pin connectors provide access to the scanner’s local Lonworks network used for both input and output connections to build a multi-sided or omni-station system. 17-pin Lonworks Connector Pinout Pin A1 A2
Name GND VS
1
CHASSIS
2 n.c.
3
CHASSIS
4 5 6 7 8 9 10 11 12 13 14 15 n.c. n.c. n.c. VS_I/O Lon A+ Lon ALon B+ Lon BSYS_I/O SYS_ENC_I/O Reserved Ref_I/O
Function Supply voltage (negative pin) Supply voltage 20 to 30 Vdc (positive pin) Cable shield A - internally connected by capacitor to chassis Not connected Cable shield B - internally connected by capacitor to chassis Not connected Not connected Not connected Supply voltage of I/O circuit Lonworks a line (positive pin) Lonworks a line (negative pin) Lonworks b line (positive pin) Lonworks b line (negative pin) System signal System signal Internally connected Reference voltage of I/O circuit
1 A1
A2 15
Male - Input 15 A1
1
A2
Female - Output 17-pin Local Lonworks Connectors
5
Page 6
DX8200A QUICK GUIDE Ethernet Version Harting RJ Industrial® Modular Connector HUB / SWITCH
DX8200A TX+
1
1
TX-
2
2
RX+
3
3 n. c.
4
4 n. c.
5
5
RX-
6
6 n. c.
7
7 n. c.
8
8
8
1
1
8
Harting RJ Industrial Female Connector n. c. = not connected
Profibus Version Profibus Connector Pin
Name
Function
1 2 3 4 5 6 7 8 9
Shield* Free B-LINE (RxD/TxD-P) CNTR-P** DGND +5 V Free A-LINE (RxD/TxD-N) CNTR-N**
Shield, protective ground resp.
* **
Received/Transmitted data-P Repeater control signal Data ground (M5V) Voltage plus (P5V)
1
5
9
6
Profibus 9-pin D-sub Female Connector
Received/Transmitted data Repeater control signal signal is optional signal is optional; RS485 level
DeviceNet Version DEVICENET CONNECTOR Pin 2 5 1 4 3
6
Name V+ CAN_L SHIELD CAN_H V-
Function Supply voltage – positive pin CAN bus data line – L Shield CAN bus data line – H Supply voltage – negative pin
4
3
1
2
5
5-pin male DeviceNet Connector
Page 7
DX8200A QUICK GUIDE
Network Termination: When building a Lonworks system the network must be properly terminated by positioning the BTK-8102 Lonworks terminator in the DX8200A master reader and the BTK-8100 Lonworks bus return in the last DX8200A slave reader. The BTK-8100 bus return provides a connector to be inserted in the Lonworks 17-pin female connector of the last slave reader in the network; while the BTK-8102 Lonworks terminator provides a different connector to be inserted in the Lonworks 17-pin male connector of the master reader: DX8200A Master
DX8200A Last Slave BTK-8100
BTK-8102
CAB-810X
Network CAB-810X
BTK-8102 and BTK-8100
Two cables are also provided as accessories to terminate and power the network: CAB-8605 and CAB-8305. CAB-8605 is a power and Lonworks termination cable to be used for connecting the DX8200A master to an external power unit within the network; while CAB-8305 is a power and bus return cable to be used for connecting the last DX8200A slave to an external power unit. This two cables must be used only for VDC models. DX8200A Master
DX8200A Last Slave
Network
Power Unit
CAB-8605
CAB-8305
CAB-8605 and CAB-8305
7
Page 8
DX8200A QUICK GUIDE
Connectivity: Examples of the most common system layouts are shown in this section, for additional layouts refer to the Reference Manual. Point-to-Point Layout Standard CAB601X
C-BOX 100
Local Host Presence Sensor*
PWR-120
*
P.S. (Presence Sensor) connected to External Trigger/PS input. Point-to-Point for Standard DC Models
Standard CAB601X
C-BOX 100**
110 - 230 Vac Local Host Presence Sensor*
*
P.S. (Presence Sensor) connected to External Trigger/PS input.
** C-BOX 100 modified to accept scanner power Point-to-Point for Standard AC Models
8
Page 9
DX8200A QUICK GUIDE Local Lonworks Networks Master
BTK-8102
CAB601X C-BOX 100**
Slave 1 CAB810X P.S.* Local Host
PWR-120
CAB830X
*
P.S. (Presence Sensor) connected to External Trigger/PS input.
** C-BOX 100 modified to accept scanner power Small Synchronized Network with 2 Readers
CAB810X
CAB810X PWR-240
Slave 3
Slave 4
CAB830X CAB860X
C-BOX 100**
CAB601X CAB810X
Slave 2
P.S.* Encoder***
CAB810X
Slave 1
Master
*
P.S. (Presence Sensor) connected to External Trigger/PS input.
**
C-BOX 100 modified to accept scanner power
***
Encoder connected to IN2/ENC input.
Local Host
Small Synchronized Network with more than 2 Readers and Single Power Unit
9