The text of a manual · part 6 of 9
DS4600A Reference Manual: INSTALLATION, pages 30 to 36
Pages 30 to 36 of 63, from DS4600A Reference Manual
The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DS-4600A
Page 30
DS4600A
2
2.5
POSITIONING
The DS4600A scanner is able to decode moving barcode labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting the DS4600A take into consideration these three ideal label position angles: Pitch 0°, Skew 15° to 30° and Tilt 0°. Follow the suggestions below for the best orientation: The Pitch angle is represented by the value P in Figure 19. Position the reader in order to minimize the Pitch angle. P
Figure 19 - Pitch Angle
The Skew angle is represented by the value S in Figure 20. Position the reader to assure at least 15° for the Skew angle. This avoids the direct reflection of the laser light emitted by the DS4600A. For raster models, this angle refers to the most inclined or external raster line, so that all other raster lines assure more than 10° Skew.
S
Figure 20 - Skew Angle
18
Page 31
INSTALLATION
2
The Tilt angle is represented by the value T in Figure 21. Position the reader in order to minimize the Tilt angle. T
Figure 21 - Tilt Angle
2.6
TYPICAL LAYOUTS
The following typical layouts refer to system hardware configurations. Dotted lines in the figures refer to optional hardware configurations within the particular layout. These layouts also require the correct setup of the software configuration parameters. Complete software configuration procedures can be found in the Guide To Rapid Configuration in the WinHost Help On Line.
19
Page 32
DS4600A
2
2.6.1
Point-to-Point
In this layout the data is transmitted to the Host on the main serial interface. Host Mode programming can be accomplished either through the main interface or the auxiliary interface. In Local Echo communication mode, data is transmitted on the RS232 auxiliary interface independently from the main interface selection. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.
c Main Serial Interface dAuxiliary Serial Interface (Local Echo) (RS232) eExternal Trigger (for On-Line Mode) Figure 22 - Point-to-Point Layout
20
Page 33
INSTALLATION
2.6.2
2
Pass Through
Pass through mode allows two or more devices to be connected to a single external serial interface. Each DS4600A transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the host. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone. The main and auxiliary ports are connected as shown in the figure below:
c Main Serial Interface (RS232) dAuxiliary Serial Interface (RS232) eExternal Trigger (for On-Line Mode) Figure 23 - Pass Through Layout
21
Page 34
DS4600A
2
2.6.3
RS232 Master/Slave
The RS232 master/slave connection is used to collect data from several scanners to build either a multi-point or a multi-sided reading system; there can be one master and up to 9 slaves connected together. The Slave scanners use RS232 only on the main and auxiliary serial interfaces. Each slave DS4600A transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the master. The Master scanner is connected to the Host on the main serial interface. The possible main interface types for the master scanner are RS232 or RS485. (20 mA C.L. can also be used if the INT-30 with C-Box 100 accessory is installed). There is a single reading phase and a single message from the master scanner to the Host computer. Either On-Line or Serial On-Line Operating modes can be used in this layout. When On-Line Operating mode is used, the external trigger signal is unique to the system however it is not necessary to bring the external trigger signal to the Slave scanners.
The main and auxiliary ports are connected as shown in the figure below.
c Main Serial Interface (Slaves RS232 only) dAuxiliary Serial Interface (RS232) eExternal Trigger (for On-Line Mode) Figure 24 - RS232 Master/Slave Layout
22
Page 35
INSTALLATION
2.6.4
2
RS485 Master/Slave
The RS485 master/slave connection is used to collect data from several scanners to build a multi-point or a multi-sided reading system; there can be one master and up to 5 slaves connected together. The slave scanners are connected together using RS485 half-duplex on the main serial interface. Every slave scanner must have a multidrop address in the range 0-4. The master scanner is also connected to the Host on the RS232 auxiliary serial interface. The External Trigger signal is unique to the system; there is a single reading phase and a single message from the master scanner to the Host computer. It is necessary to bring the External Trigger signal to all the scanners. The main and auxiliary ports are connected as shown in the figure below.
c Auxiliary Serial Interface (RS232) d Main Serial Interface (RS485 Half-Duplex) eExternal Trigger Figure 25 - RS485 Master/Slave Layout
NOTE
The auxiliary serial interface of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode Programming procedure. The termination resistors of the RS485 bus must not be installed.
23
Page 36
DS4600A
2
2.6.5
Multiplexer
Each scanner is connected to a Multiplexer (for example MX4000) with the RS485 half duplex main interface.
c Main Serial Interface (RS485 Half-Duplex) dAuxiliary Serial Interface (Local Echo) (RS232) eExternal Trigger (for On-Line Mode) Figure 26 - Multiplexer Layout
The auxiliary serial interface of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode Programming procedure. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.
24