Page 16

DS4600A

2

2

INSTALLATION

2.1

PACKAGE CONTENTS

Verify that the DS4600A reader and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes: •

DS4600A reader with cable

•

Quick Reference Guide

•

Barcode Test Chart

•

WinHost CD

•

Mounting kit: - Mounting screws and washers (4 ea.) - Mounting bracket (1)

Figure 1 - DS4600A Package Contents

4

Page 17

INSTALLATION

2.2

2

MECHANICAL INSTALLATION

DS4600A can be installed to operate in different positions. The four screw holes (M4 x 5) on the body of the reader are for mechanical fixture (Figure A, 5). The diagram below gives the overall dimensions of the scanner and may be used for its installation.

22* 0.86 20.2 14.8 0.58 0.8 M4 N°2

83.5 3.29

101

3.98

58 2.28

37 1.46

87.9 3.46

81 3.19

39.4 1.55

41.8 1.64

8.25 0.32

10 0.39

20 0.79

Refer to paragraph 2.4 for correct positioning.

3.75 0.15 37 1.47

5 0.2

DS4600A

18 0.70

11.8 0.46

32.5 1.28

M4 N° 4

23 0.90

42 1.65

Mounting hole depth M4 X 5

* The quote refers to the scan line

20 0.79

Figure 2 - Overall Dimensions for 2XXX Models

18*

83.5 3.29

101

3.98

58 2.28

37 1.46

87.9 3.46

81 3.19

39.4 1.55

41.8 1.64

8.25 0.32

10 0.39

0.71 20.2 14.8 0.58 0.8 M4 N°2

5 0.2

3.75 0.15 37 1.47

Mounting hole depth M4 X 5

42 1.65

18 0.70

11.8 0.46

32.5 1.28

M4 N° 4

23 0.90

* The quote refers to the scan line

Figure 3 - Overall Dimensions for 3XXX Models

5

Page 18

DS4600A

115 4.53

5.5 0.22

2

5.5 0.22

10°

57.3 2.26

35°

5 5. 2 2 0.

3 0.12

39 1.54

5.5 0.22

5 0.20

Figure 4 - Mounting Bracket Dimensions

6 mm inch

Page 19

INSTALLATION

2.3

2

ELECTRICAL CONNECTIONS

DS4600A is equipped with a cable terminated by a 25-pin D-sub connector for connection to the power supply and input/output signals. The details of the connector pins are indicated in the following table:

CAUTION

Do not connect GND and SGNDs (Main or Aux) to different (external) ground references. GND and SGNDs (Main and Aux) are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.

Figure 5 - 25-pin D-sub Connector

25-pin D-sub connector pinout Pin

Name

Function

13 25 1 9 18 19 6 10 14 15 8 22 11 12 20 21 23 24 16 17

VS GND CHASSIS VS EXT TRIG+ EXT TRIGIN1 + IN1 IN2 + IN2 OUT1 + OUT1 OUT2 + OUT2 RXAUX TXAUX SGND Aux GND Reserved Reserved

Power supply input voltage + Power supply input voltage Chassis Ground External Trigger supply voltage + External Trigger + External Trigger Input 1 + Input 1 Input 2 + Input 2 Output 1 + Output 1 Output 2 + Output 2 Auxiliary RS232 input Auxiliary RS232 output Signal Ground Auxiliary interface Power supply voltage -

RS232 2 3 4 5 7

Main interface (see par. 2.3.2)

TX232 RX232 RTS232 CTS232 SGND Main

RS485 full-duplex TX485+ RX485+ TX485RX485SGND Main

RS485 half-duplex RTX485+ RTX485SGND Main

7

Page 20

DS4600A

2

2.3.1

Power Supply

Power can be supplied to the scanner through the pins provided on the 25-pin connector used for communication with the host (Figure 6):

DS4600A

VS GND CHASSIS

USER INTERFACE 13

V+ (10 - 30 Vdc)

25 1

GND Earth Ground

CHASSIS

Figure 6 - Power Supply Connections or through the jack connector on the side of the 25-pin connector for connections to a UL Listed Direct Plug-in Power Unit (Figure 7). If the jack input is used to supply power to the DS4600A, pin 13 is automatically disconnected; the supply voltage for the external trigger remains on pin 9. The plug connector is not supplied with the DS4600A.

GND Jack

Plug

V+ (10 - 30 Vdc)

Figure 7 - Power Supplied Using the Jack Connector

For Standard models, the power must be between 10 and 30 Vdc only. There is a current peak of about 1A at 10 V during power on caused by the motor starting. For Integrated Heater models, the power must be 24Vdc only. It is recommended to connect pin 1 (CHASSIS) to a common earth ground.

8

Page 21

INSTALLATION

2.3.2

2

Main Serial Interface

The signals relative to the following serial interface types are available on the input/output connector of the DS4600A. The main serial interface type and its relative parameters (baud rate, data bits, etc.) are selected via software either using the WinHost utility program or Host Mode programming. For more details refer to the section "Main Interface Menu" in the WinHost Help On Line. Details regarding the connections and use of the main interface selection are given in the next paragraphs.

RS232 Interface The serial interface is used in this case for point-to-point connections; it handles communication with the host computer and allows both transmission of code data and the configuration of the scanner. This is the default interface. The following pins of the 25-pin connector are used for RS232 interface connection: Pin 2 3 4 5 7

Name TX232 RX232 RTS232 CTS232 SGND Main

Function transmitted data received data request to send clear to send signal ground main interface

It is always advisable to use shielded cables. The overall maximum cable length must be less than 15 m (49.2 ft). DS4600A

USER INTERFACE 2

TX232

3

RX232

4

RTS232

5

CTS232

7

SGND Main

RXD TXD DCD DTR SGND Earth Ground

RTS/CTS HARDWARE HANDSHAKING ENABLED

Figure 8 - RS232 Main Interface Connections

9

Page 22

DS4600A

2

The RTS232 and CTS232 signals control data transmission and synchronize the connected devices.

Figure 9 - RS232 Control Signals

If the RTS/CTS handshaking protocol is enabled, the DS4600A activates the RTS232 output to indicate a message is to be transmitted. The receiving unit activates the CTS232 input to enable the transmission.

RS485 Full-Duplex Interface The RS485 full-duplex (5 wires + shield) interface is used for non-polled communication protocols in point-to-point connections over longer distances (max 1200 m / 3940 ft) than those acceptable for RS232 communications or in electrically noisy environments. The following pins of the 25-pin connector are used for RS485 full-duplex communications: Pin 2 4 3 5 7

10

Name TX485+ TX485RX485+ RX485SGND Main

Function RS485 transmitted data + RS485 transmitted data RS485 received data + RS485 received data signal ground main interface