Page 37

INSTALLATION

2

The Tilt angle is represented by the value T in Figure 27. Position the reader in order to minimize the Tilt angle. T

Figure 27 - Tilt angle

2.6

TYPICAL LAYOUTS

The following typical layouts refer to system hardware configurations. Dotted lines in the figures refer to optional hardware configurations within the particular layout. These layouts also require the correct setup of the software configuration parameters. Complete software configuration procedures can be found in the Guide To Rapid Configuration in the WinHost Help On Line.

25

Page 38

DS4600

2

2.6.1

Point-to-Point

In this layout the data is transmitted to the Host on the main serial interface. Host Mode programming can be accomplished either through the main interface or the auxiliary interface. In Local Echo communication mode, data is transmitted on the RS232 auxiliary interface independently from the main interface selection. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.

2

DS4600

Terminal

DS4600

1 Host

3

1 Main serial interface 2 Auxiliary serial interface (Local Echo) 3 External Trigger (for On-Line mode)

Figure 28 - Point-to-Point layout

26

Page 39

INSTALLATION

2.6.2

2

Pass Through

Pass through mode allows two or more devices to be connected to a single external serial interface. Each DS4600 transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the host. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone. The main and auxiliary ports are connected as shown in the figure below: 1 Main serial interface 2 Auxiliary serial interface 3 External Trigger (for On-Line mode) 1

2

DS4600

DS4600

1

DS4600

DS4600

Host

3

3

Figure 29 - Pass through layout

27

Page 40

DS4600

2

2.6.3

RS232 Master/Slave

The RS232 master/slave connection is used to collect data from several scanners to build either an omni-directional or a multi-sided reading system; there can be one master and up to 9 slaves connected together. The slave scanners are connected to the main and auxiliary serial interfaces. Each slave DS4600 transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the master. The master scanner is connected to the Host on the main serial interface. The possible main interface types for the Master scanner are RS232 or RS485. (20 mA C.L. can also be used if the INT-24 accessory is installed). Either On-Line or Serial On-Line Operating modes can be used in this layout. When On-Line Operating mode is used, the external trigger signal is unique to the system however it is not necessary to bring the external trigger signal to the Slave scanners. The main and auxiliary ports are connected as shown in the figure below.

2

1 DS4600

DS4600 Slave

2

DS4600 Slave DS4600 DS4600

1 3

1 Main serial interface 2 Auxiliary serial interface

Host

3 External Trigger (for On-Line mode)

Figure 30 - RS232 Master/Slave layout

28

DS4600 Master

1

Page 41

INSTALLATION

2.6.4

2

RS485 Master/Slave

The RS485 master/slave connection is used to collect data from several scanners to build either an omni-directional or a multi-sided reading system; there can be one master and up to 5 slaves connected together. The slave scanners are connected together using RS485 half-duplex on the main serial interface. Every slave scanner must have a multidrop address in the range 0-4. The master scanner is also connected to the Host on the RS232 auxiliary serial interface. The External Trigger signal is unique to the system; there is a single reading phase and a single message from the master scanner to the Host computer. It is necessary to bring the External Trigger signal to all the scanners. The main and auxiliary ports are connected as shown in the figure below.

1 Auxiliary serial interface

Host

2 RS485HD Main serial interface

1

3 External Trigger

2 1 DS4600

DS4600 Slave

DS4600 Slave

DS4600

DS4600

*Master

3 1

Figure 31 - RS485 Master/Slave layout * DS4600-3xxx cannot be used as the Master in the RS485 Master/Slave layout. For a list of Master compatible scanners see the Guide to Rapid configuration in the WinHost Help On Line.

NOTE

The auxiliary serial interface of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode Programming procedure. The termination resistors of the RS485 bus must not be installed.

29

Page 42

DS4600

2

2.6.5

Multiplexer

Each scanner is connected to an MX4000 with the RS485 half duplex mode on the main interface. 0

1

3

2

DS4600

3

2

DS4600

DS4600

2

31

1

3

Host 1 Main interface

MX4000

2 Auxiliary interface (Local Echo) 3 External Trigger (for On-Line mode)

Figure 32 - Multiplexer layout

The auxiliary serial interface of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode Programming procedure. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.

30

Page 43

READING FEATURES

3

3

READING FEATURES

3.1

ADVANCED CODE RECONSTRUCTION

The traditional way of barcode reading could be called "Linear Reading". In this case, the laser beam crosses the barcode symbol from its beginning to its end as shown in Figure 33.

Laser Beam Figure 33 - Linear reading

In “Advanced Code Reconstruction” mode, it is no longer necessary for the laser beam to cross the label from the start to the end. With just a set of partial scans on the label (obtained using the motion of the label itself), the DS4600 is able to "reconstruct" the barcode. A typical set of partial scans is shown in Figure 34.

Code Direction

Figure 34 - Partial scans

None of the partial scans contains the whole label. The decoder aligns each partial scan correctly and combines them in order to obtain the entire code. The alignment is performed by calculating the time difference from one partial scan to another using a reference code element.

31

Page 44

DS4600

3

3.1.1

Tilt Angle for Advanced Code Reconstruction

The most important parameter in Advanced Code Reconstruction is the value of the maximum tilt angle (α maximum) under which the code reconstruction process is still possible. We define the Tilt angle as the angle (α) between the laser beam and a line parallel to the barcode label, as shown in Figure 35. Laser Beam 0° to α max

α = tilt angle

α Figure 35 - Tilt angle

The formulas to calculate α maximum depend on various parameters such as: label height, number of scans per second, code motion speed, etc. To obtain α maximum for your application, please contact your Datalogic representative. You must remember that the decoder will be able to read the label with a tilt angle between + α max and - α max as shown in Figure 36 (the shaded zones are the NO READ zones). 0°

- α +α

Laser Beam

Figure 36 - Reading zones with α max

32

Page 45

READING FEATURES

3.2

3

DECODING CAPACITY IN LINEAR MODE

When in Linear Reading mode, the number of reads performed by the DS4600 and therefore the decoding capacity, is influenced by the following parameters: • number of scans per second

• code motion speed

• label dimensions

• scan direction with respect to code motion

At least 5 scans during the code passage should be allowed to ensure a successful read.

3.2.1

Step Ladder Mode Direction of code movement at LS speed LH

DS4600

Laser beam

Figure 37 - "Step Ladder" scanning mode

If scanning is perpendicular to the direction of the code movement (Figure 37), the number of effective scans performed by the reader is given by the following formula: SN = [(LH/LS) * SS] - 2 These symbols signify: SN = number of effective scans LH = label height (in mm) LS = label movement speed (in mm/s) SS = number of scans per second

33