The text of a manual · part 6 of 6
DS4300 Installation Manual, pages 46 to 53
Pages 46 to 53 of 53
The original document is the PDF (796 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DS-4300
Page 46
DATALOGIC
DS4300
3.3 PERFORMANCE The DS4300 scanner reads codes with densities from 0.20 mm (8 mils) to 1.00 mm (40 mils) in the zone between 50 mm (1.9 in) and 400 mm (15.7 in) from the emission window. DS4300 can be optimized for reading high density codes (between 0.20 mm (8 mils) and 0.30 mm (12 mils) by configuring the Code Resolution parameter (see WinHost Help On Line). Refer to the diagrams given in paragraph 3.4 for further details on the reading features. These diagrams are taken on various resolution sample codes at a 25 °C ambient temperature, depending on the conditions in the notes under each diagram. If standard devices do not satisfy specific requirements, contact your nearest Datalogic distributor, supplying code samples, to obtain complete information on the reading possibilities.
Reading Features - 3.5
Page 47
DS4300
DATALOGIC
3.4 READING DIAGRAMS The following diagrams show the reading distance for barcodes with different densities.
DS4300-100X (Code Resolution Standard)
0.50 mm (20 mils) 0.60 mm (24 mils)
≥ 0.80 mm (31 mils)
NOTE: (0,0) is the center of the laser beam output window CONDITIONS: Test Codes used "Pitch" angle "Skew" angle "Tilt" angle Reading Mode Code Resolution
3.6 - Reading Features
= Interleaved 2/5 and Code 39 (according to the Datalogic Barcode Test Chart) = 0° = 10° = 0° = Linear = Standard
Page 48
DATALOGIC
DS4300
DS4300-100X (Code Resolution High)
0.20 mm (8 mils)
0.30 mm (12 mils)
NOTE: (0,0) is the center of the laser beam output window CONDITIONS: Test Codes used "Pitch" angle "Skew" angle "Tilt" angle Reading Mode Code Resolution
= Interleaved 2/5 and Code 39 (according to the Datalogic Barcode Test Chart) = 0° = 10° = 0° = Linear = High
Reading Features - 3.7
Page 49
DS4300
DATALOGIC
This page is intentionally left blank.
3.8 - Reading Features
Page 50
DATALOGIC
DS4300
4 MAINTENANCE 4.1 CLEANING Clean the laser beam output window periodically for continued correct operation of the reader. Dust, dirt, etc. on the window may alter the reading performance. Repeat the operation frequently in particularly dirty environments. Use soft material and alcohol to clean the window and avoid any abrasive substances.
WARNING Clean the window of the DS4300 when the scanner is turned off or, at least when the laser beam is deactivated.
Maintenance - 4.1
Page 51
DS4300
DATALOGIC
This page is intentionally left blank.
4.2 - Maintenance
Page 52
DATALOGIC
DS4300
5 TECHNICAL FEATURES ELECTRICAL FEATURES Power Supply voltage Power consumption max. Serial Interfaces Main
10 to 30 Vdc 5.5 W RS232, RS485 full-duplex, RS485 half-duplex (20 mA C.L. only with INT-24 accessory )
Auxiliary
RS232
Baud rates
1200 to 115200
Inputs Voltage max. Input current max.
External Trigger, IN1, IN2 (optocoupled NPN or PNP) 30 Vdc 25 mA
Outputs
User-defined OUT1 and OUT2 (optocoupled open emitter, open collector)
VCE max.
40 Vdc
Collector current max. VCE saturation Power dissipation max.
40 mA continuous; 130 mA pulsed 1V at 10 mA max. 90 mW at 40 °C (Ambient temp.)
OPTICAL FEATURES Light source Wave length (Note 1) Safety class
Semiconductor laser diode 630 ~ 680 nm Class 2 - IEC 825-1; Class II - CDRH
READING FEATURES (Note 2) Scan rate
800 scans/sec
Aperture angle
60°
Reading distance
50 mm (1.9 in) to 400 mm (15.7 in)
Maximum resolution
0.20 mm (8 mils)
USER INTERFACE LED indicators
Ready, Good Read, External Trigger , Data Transmission, Laser Beam Active
Technical Features - 5.1
Page 53
DS4300
DATALOGIC
SOFTWARE FEATURES READABLE CODE SYMBOLOGIES • EAN/UPC
• Code 93
• 2/5 Interleaved
• Code 128
• Code 39
• EAN 128
• Codabar
• Pharmacode
CODE SELECTION up to six codes during one reading phase
DECODING SAFETY can enable multiple good reads of same code
HEADERS AND TERMINATORS up to four headers and four terminators
OPERATING MODES
ON LINE, AUTOMATIC, SERIAL ON LINE, TEST
CONFIGURATION MODES
• through menus using WinHost utility • receiving commands from one of the serial ports (HOST MODE)
PARAMETER STORAGE
Non-volatile internal memory
ENVIRONMENTAL FEATURES Operating temperature (Note 3)
0 to 40 °C (32 to 104 °F)
Storage temperature
-20 to 70 °C (-4 to 158 °F)
Humidity max.
90% non condensing
Vibration resistance
IEC 68-2-6 test FC 1.5 mm; 10 to 55 Hz; 2 hours on each axis
Shock resistance
IEC 68-2-27 test EA 30G; 11 ms; 3 shocks on each axis
Protection class
IP65
PHYSICAL FEATURES Mechanical dimensions
101 x 83.5 x 42 mm (3.97 x 3.29 x 1.65 in.)
Weight about 800 g. (28.2 oz.)
Note 1:
The features given are typical at a 25 °C ambient temperature (if not otherwise indicated).
Note 2:
Further details given in paragraphs 3.3 and 3.4.
Note 3:
If the reader is used in high temperature environments (over 35 °C), use of the Beam shutter is advised (for details refer to the WinHost Help On Line).
5.2 – Technical Features