The text of a manual · part 5 of 6

DS4300 Installation Manual, pages 37 to 45

Pages 37 to 45 of 53

The original document is the PDF (796 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic DS-4300

Page 37

DS4300

DATALOGIC

2.6.2 Pass Through Pass through mode allows two or more devices to be connected to a single external serial interface. Each DS4300 transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the host. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone. The main and auxiliary ports are connected as shown in the figure below: DS4300

2

1

DS4300

1

3

Host

3

1

Main serial interface

2

Auxiliary serial interface

3

External Trigger (for On-Line mode)

Figure 2.29 - Pass through layout

2.22 - Installation

Page 38

DATALOGIC

DS4300

2.6.3 RS232 Master/Slave The RS232 master/slave connection is used to collect data from several scanners to build either an omni-directional or a multi-sided reading system; there can be one master and up to 9 slaves connected together. The Slave scanners use RS232 only on the main and auxiliary serial interfaces. Each slave DS4300 transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the Master. The Master scanner is connected to the Host on the main serial interface. The possible main interface types for the Master scanner are RS232 or RS485. (20 mA C.L. can also be used if the INT-24 accessory is installed). Either On-Line or Serial On-Line Operating modes can be used in this layout. When On-Line Operating mode is used, the external trigger signal is unique to the system however it is not necessary to bring the external trigger signal to the Slave scanners. The main and auxiliary ports are connected as shown in the figure below. 1

DS4300 Slave

2

2

DS4300 Slave 1 DS4300 Master

1 3

2

Main serial interface Auxiliary serial interface

3

External Trigger (for On-Line mode)

1

Host

Figure 2.30 - RS232 Master/Slave layout

Installation - 2.23

Page 39

DS4300

DATALOGIC

2.6.4 RS485 Master/Slave The RS485 master/slave connection is used to collect data from several scanners to build either an omni-directional or a multi-sided reading system; there can be one master and up to 5 slaves connected together. The Slave scanners are connected together using RS485 half-duplex on the main serial interface. Every Slave scanner must have a multidrop address in the range 0-4. The Master scanner is also connected to the Host on the RS232 auxiliary serial interface. The External Trigger signal is unique to the system; there is a single reading phase and a single message from the master scanner to the Host computer. It is necessary to bring the External Trigger signal to all the scanners. The main and auxiliary ports are connected as shown in the figure below.

DS4300 Slave

2

1 1 DS4300 Slave

3

1 2

Auxiliary serial interface RS485 HD Main serial interface

3

External Trigger

1

* Master

Host

Figure 2.31 - RS485 Master/Slave layout * DS4300 cannot be used as the Master in the RS485 Master/Slave layout. For a list of Master compatible scanners see the Guide to Rapid configuration in the WinHost Help On Line.

2.24 - Installation

Page 40

DATALOGIC

DS4300

NOTE The auxiliary serial interface of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode Programming procedure. The termination resistors of the RS485 bus must not be installed.

2.6.5 Multiplexer Each scanner is connected to an MX4000 with the RS485 half duplex mode on the main interface. 1

31

1

0

MX4000 2 Host

2 3

2 3

3

1

RS485 HD Main interface

2

Auxiliary interface (Local Echo)

3

External Trigger (for On-Line mode)

Figure 2.32 - Multiplexer layout

The auxiliary serial interface of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode Programming procedure. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.

Installation - 2.25

Page 41

DS4300

DATALOGIC

This page is intentionally left blank.

2.26 - Installation

Page 42

DATALOGIC

DS4300

3 READING FEATURES 3.1 ADVANCED CODE RECONSTRUCTION The traditional way of barcode reading could be called "Linear Reading". In this case, the laser beam crosses the barcode symbol from its beginning to its end as shown in Figure 3.1.

Laser Beam

Figure 3.1 - Linear reading

In “Advanced Code Reconstruction” mode, it is no longer necessary for the laser beam to cross the label from the start to the end. With just a set of partial scans on the label (obtained using the motion of the label itself), the DS4300 is able to "reconstruct" the barcode. A typical set of partial scans is shown in Figure 3.2.

Code Direction

Figure 3.2 - Partial scans

None of the partial scans contains the whole label. The decoder aligns each partial scan correctly and combines them in order to obtain the entire code. The alignment is performed by calculating the time difference from one partial scan to another using a reference code element.

Reading Features - 3.1

Page 43

DS4300

DATALOGIC

3.1.1 Tilt Angle for Advanced Code Reconstruction The most important parameter in Advanced Code Reconstruction is the value of the maximum tilt angle (α maximum) under which the code reconstruction process is still possible. We define the Tilt angle as the angle (α) between the laser beam and a line parallel to the barcode label, as shown in Figure 3.3. Laser Beam

0° to α max

α = tilt angle

α Figure 3.3 - Tilt angle

The formulas to calculate α maximum depend on various parameters such as: label height, number of scans per second, code motion speed, etc. To obtain α maximum for your application, please contact your Datalogic representative. You must remember that the decoder will be able to read the label with a tilt angle between + α max and - α max as shown in Figure 3.4 (the shaded zones are the NO READ zones). 0°

- α +α

Laser Beam

Figure 3.4 - Reading zones with α max

3.2 - Reading Features

Page 44

DATALOGIC

DS4300

3.2 DECODING CAPACITY IN LINEAR MODE When in Linear Reading mode, the number of reads performed by the DS4300 and therefore the decoding capacity, is influenced by the following parameters: • number of scans per second • code motion speed • label dimensions • scan direction with respect to code motion At least 5 scans during the code passage should be allowed to ensure a successful read.

3.2.1 Step Ladder Mode Code motion moving at LS speed DS4300

LH

Laser Beam

Figure 3.5 - "Step Ladder" scanning mode

If scanning is perpendicular to the code motion direction (Figure 3.5 - "step ladder" mode), the number of effective scans performed by the reader is given by the following formula: SN = [(LH/LS) * SS] - 2 These symbols signify: SN = number of effective scans LH = label height (in mm) LS = label movement speed (in mm/s) SS = number of scans per second

Reading Features - 3.3

Page 45

DS4300

DATALOGIC

For example, the DS4300 (800 scans/sec.), for a 25 mm high code moving at 1250 mm/s performs: [(25/1250) * 800] - 2 = 14 effective scans.

3.2.2 Picket Fence Mode Laser Beam Code motion moving at LS speed

DS4300

LW

FW

Figure 3.6 - "Picket Fence" scanning mode

If scanning is parallel to the code motion, (Figure 3.6 - "picket fence" mode), the number of effective scans is given by: SN = [((FW-LW)/LS) * SS] - 2 These symbols signify: SN = number of effective scans FW = reading field width (in mm) LW = label width (in mm) LS = label movement speed (in mm/s) SS = scans per second

For example, for a 100 mm wide code moving in a point where the reading field is 200 mm wide at a 2000 mm/s speed, the DS4300 (800 scans per sec.), performs: [((200-100)/2000) * 800] - 2 = 38 scans

3.4 - Reading Features