INSTALLATION

2.8

2

TYPICAL LAYOUTS

The DS41 barcode reader was specifically designed for industrial applications. A typical use is real time identification of moving objects on conveyor belts. A photoelectric sensor used as External Trigger signals when an object enters the scanner reading zone (see Figure 33).

DS41 DS41

1 Host

2

1 Main serial interface 2 External trigger (for On-Line mode)

Figure 33 - DS41 typical layout

DS41 can be mounted vertically or horizontally to read labels in the two standard 'picket fence' or 'step ladder' positions. A system can be configured to read labels in any orientation using several scanners positioned at different angles. For each application it is advised that the length of the scan line, the scan speed, the height of the bars and the code motion speed with respect to the scanner, allow at least five scans on the code. The possibility of using raster models allows a greater surface area of the code to be scanned, increasing the probability of correct reads even if the code printing quality is poor or the code is positioned incorrectly.

29

Page 42

DS41

2

2.8.1

Master-Slave

The master-slave layout is used to collect data from several scanners to build a multisided reading system; there can be one master and up to 5 slaves connected in RS485 Half Duplex on the main serial interface. The master scanner is also connected to a host computer with the RS232 auxiliary interface. The External Trigger signal is unique to the system; there is a single reading phase and a single message from the master scanner to the host computer. In every scanner the jumper block for the selection of the main serial interface type must be set for RS485 Half Duplex (see paragraph 2.3). In every slave scanner the multidrop address selection must be set within the range from 0 to 4 max (see paragraph 2.6.2 under "RS485 Half Duplex interface"). The DIP switch selections in the master scanner are ignored.

1 Auxiliary serial interface

Host

2 Main serial interface

1

3 External trigger (for On-Line mode)

2

DS41 Slave

1 DS41

DS41 Slave

DS41

DS41

DS41 Master

3 1

Figure 34 - Master-slave layout

The auxiliary serial port of the slave scanners is only used for configuration. NOTE

30

The termination resistors of the RS485 bus must not be installed.

Page 43

INSTALLATION

2.8.2

2

Local Echo

In Local Echo communication mode, data is transmitted on the RS232 auxiliary interface independently from the main interface selection. Host Mode programming can be accomplished either through the main interface or the auxiliary interface in Local Echo mode. Terminal 1 Main serial interface 2 Auxiliary serial interface 3 External trigger (for On-Line mode)

2

DS41

DS41

1

Host

3

Figure 35 - Local echo layout

31

Page 44

DS41

2

2.8.3

Pass Through

Pass through mode allows two or more devices to be connected to a single external serial interface. Each DS41 transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the host. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone. The main and auxiliary ports are connected as shown in the figure below: 1 Main serial interface 2 Auxiliary serial interface 3 External Trigger (for On-Line mode) 1

2

DS41

DS41

1

DS41

Host

3

Figure 36 - Pass through layout

32

3

DS41

Page 45

INSTALLATION

2.8.4

2

Multiplexer

Each scanner is connected to an MX4000 with the RS485 half duplex mode on the main interface. 0

1

3

31 2

DS41

3

DS41

2

DS41

2

1

3

Host 1 Main interface

MX4000

2 Auxiliary interface (Local Echo) 3 External Trigger (for On-Line mode)

Figure 37 – Multiplexer layout

The auxiliary serial interface of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode Programming procedure. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.

33

Page 46

DS41

3

3

READING FEATURES

The number of reads performed by the DS41 and therefore the decoding capacity, is influenced by the following parameters: • number of scans per second

• code movement speed

• label dimensions

• scan direction with respect to code movement

At least 5 scans during the code passage should be allowed to ensure a successful read.

3.1

STEP LADDER MODE Direction of code movement at LS speed DS41

LH

Laser beam

Figure 38 - "Step Ladder" scanning mode

If scanning is perpendicular to the direction of code movement (Figure 38), the number of effective scans performed by the reader is given by the following formula: SN = [(LH/LS) * SS] - 2 These symbols signify: SN = number of effective scans LH = label height (in mm) LS = label movement speed (in mm/s) SS = number of scans per second

34

Page 47

READING FEATURES

3

For example, the DS41 (800 scans/sec.), for a 25 mm high code moving at 1250 mm/s performs: [(25/1250) * 800] - 2 = 14 effective scans.

3.2

PICKET FENCE MODE

Direction of code movement at LS speed

DS41

Laser beam LW FW

Figure 39 - "Picket Fence" scanning mode

If scanning is parallel to the code movement, (Figure 39), the number of effective scans is given by: SN = [((FW-LW)/LS) * SS] - 2 These symbols signify: SN = number of effective scans FW = reading field width (in mm) LW = label width (in mm) LS = label movement speed (in mm/s) SS = scans per second For example, for a 50 mm wide code moving in a point where the reading field is 250 mm wide at a 1500 mm/s speed, the DS41 (800 scans per sec.), performs: [((250-50)/1500) * 800] - 2 = 104 scans

35

Page 48

DS41

3

3.3

PERFORMANCE

The DS41 scanner is available in four standard versions according to the optical resolution characteristics (see paragraph 1.3). The Standard resolution version is a general purpose model whose optical resolution allows code reading from 0.20 mm (8 mils) to 1.00 mm (40 mils) narrow bars in the zone between 50 mm (1.9 in) and 400 mm (15.7 in) from the emission window. This version can distinguish between high density codes in the range between 0.20 mm (8mils) and 0.30 mm (12 mils) and low density codes above 0.33 mm (13 mils) by programming the software resolution parameter (see the section "Scanner Resolution" in the WinHost Help On Line). The Very High resolution version has an optical resolution that allows reading very high density codes (typical values from 0.10 mm (4 mils) to 0.20 mm (8 mils) narrow bars) in the zone from 55 mm (2.2 in) to 125 mm (4.9 in) from the emission window. The software resolution parameter for this version should be set to high (see the section "Scanner Resolution" in the WinHost Help On Line). The Raster version R1 is a raster model used to read codes from 0.20 mm (8 mils) to 1.00 mm (40 mils) narrow bars with a raster aperture of about 12 mm (0.5 in) at a 200 mm (7.9 in) distance. The Raster version R2 is a raster model used to read codes from 0.20 mm (8 mils) to 1.00 mm (40 mils) narrow bars with a raster aperture of about 40 mm (1.6 in) at a 200 mm (7.9 in) distance. Refer to the diagrams given in paragraph 3.4 for further details on the reading features. These diagrams refer to the two standard optical versions and are taken on various resolution sample codes at a 25 °C ambient temperature, depending on the conditions in the notes under each diagram. If standard devices do not satisfy specific requirements, contact your nearest Datalogic distributor, supplying code samples, to obtain complete information on the reading possibilities.

36

Page 49

READING FEATURES

3.4

3

READING DIAGRAMS

DS41-1x (Standard Resolution, 800 scans/s)

5

0

1

0

20

2 40

3 60

4

5

6

7

8

9

10

11

(in)

80 100 120 140 160 180 200 220 240 260 280 (mm)

120

4 100 3

80 60

2 40 1

20

0

0

1

20

2

0.20 mm (8 mils)

0.30 mm (12 mils)

40 60

3

80

4

100

5

120 (mm)

(in) Note: (0,0) is the center of the laser beam output window.

CONDITIONS Code PCS "Pitch" angle "Skew" angle "Tilt" angle SW Resolution =

= = = = =

Interleaved 2/5 or Code 39 0.90 0° 10° 0° High

37

Page 50

DS41

3 DS41-1x (Standard Resolution, 800 scans/s)

10 8 6

0

2

0

40

4

6

8

10

12

14

16

18

20

240 200

0.50 mm (20 mils)

160 0.60 mm (24 mils)

120 4 80 2

40

0

0

2

40

4

≥ 0.80 mm (31 mils)

80 120

6

160

8

200

10

240 (mm)

(in) Note: (0,0) is the center of the laser beam output window.

CONDITIONS Code PCS "Pitch" angle "Skew" angle "Tilt" angle SW Resolution

38

(in)

80 120 160 200 240 280 320 360 400 440 480 520 (mm)

= = = = = =

Interleaved 2/5 or Code 39 0.90 0° 10° 0° Low