The text of a manual · part 6 of 6
DS41 Installation Manual, pages 51 to 55
Pages 51 to 55 of 55
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DS-41
Page 51
READING FEATURES
3
DS41-2x (Very High resolution, 800 scans/s)
0 0
1 10
20
2 30
40
50
3 60
70
4 80
5
90 100 110 120 130
(in) (mm)
60 2
50 40 30
1
0.20 mm (8 mils)
20 10 0
0.15 mm (6 mils)
0 10
0.10 mm (4 mils)
20 1 30 40 2
50 60 (mm)
(in)
Note: (0,0) is the center of the laser beam output window.
CONDITIONS: Code PCS "Pitch" angle "Skew" angle "Tilt" angle SW Resolution =
= = = = =
Interleaved 2/5 or Code 39 0.90 0° 10° 0° High
39
Page 52
DS41
4
4
MAINTENANCE
4.1
CLEANING
Clean the laser beam output window periodically for continued correct operation of the reader. Dust, dirt, etc. on the window may alter the reading performance. Repeat the operation frequently in particularly dirty environments. Use soft material and alcohol to clean the window and avoid any abrasive substances.
Clean the window of the DS41 when the scanner is turned off or, at least when the laser beam is deactivated. WARNING
40
Page 53
TECHNICAL FEATURES
5
5
TECHNICAL FEATURES
ELECTRICAL FEATURES Power Supply voltage Power consumption max. Serial Interfaces Main
10 to 30 Vdc 5W
Auxiliary Baud rates
RS232, RS485 Full Duplex, RS485 Half Duplex, 20 mA Passive C. L. RS232 150 to 19200
Inputs External Trigger Voltage max. Input current max.
(optocoupled NPN or PNP) 30 Vdc 25 mA
Outputs No Read, Right Read, Wrong Read VCE max.
(optocoupled) 40 Vdc
Collector current max. VCE saturation
40 mA continuous; 130 mA pulsed 1V at 10 mA max.
Power dissipation max.
90 mW at 40 °C (Ambient temp.)
OPTICAL FEATURES Light source Wave length (Note 1) Safety class
Semiconductor laser diode 630 ~ 680 nm Class 2
READING FEATURES (Note 2) Scan rate Reading distance Maximum resolution Aperture angle
800 scans/second 50 to 400 mm 0.1 mm 60 degrees
USER INTERFACE LED indicators
Power, Laser Beam Active, Barcode Decoded, External Trigger Active, Data Tx
41
Page 54
DS41
5 SOFTWARE FEATURES READABLE CODE SYMBOLOGIES • • • •
Code 93 (Standard and Full ASCII) EAN/UPC (including Add-on 2 and Add-on 5) Code 39 (Standard and Full ASCII) 2/5 Interleaved
•
Codabar
•
Code 128
• •
EAN 128 Plessey
CODE SELECTION up to six codes during one reading phase
CODE POSITON can be verified and displayed
DECODING SAFETY can enable multiple good reads of same code
HEADERS AND TERMINATORS up to four headers and four terminators
OPERATING MODES
ON LINE, AUTOMATIC, SERIAL ON LINE, TEST
CONFIGURATION MODES
• through menus using WinHost utility • receiving commands from one of the
PARAMETER STORAGE
Non-volatile internal EEPROM serial ports (HOST MODE)
ENVIRONMENTAL FEATURES Operating temperature (Note 3) Storage temperature Humidity max. Vibration resistance Shock resistance Protection class
0° to 40 °C (32° to 104 °F) -20° to 70 °C (-4° to 158 °F) 90% non condensing IEC 68-2-6 test FC 1.5 mm; 10 to 55 Hz; 2 hours on each axis IEC 68-2-27 test EA 30G; 11 ms; 3 shocks on each axis IP65
PHYSICAL FEATURES Mechanical dimensions Weight
101 x 83.5 x 42 mm (3.98 x 3.29 x 1.65 in) 800 g. (28.2 oz.)
Note 1:
The features given are typical at a 25 °C ambient temperature (if not otherwise indicated).
Note 2: Note 3:
Further details given in paragraphs 3.3 and 3.4. If the reader is used in high temperature environments (over 35 °C), use of the Beam shutter is advised (for details refer to the WinHost Help-On-Line).
42
Page 55
We
DATALOGIC S.p.A. Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy declare under our sole responsibility that the product DS41-XX, Laser Scanner and all its models to which this declaration relates is in conformity with the following standards or other normative documents EN 55022, August 1994:
LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT (ITE)
EN 50082-2, March 1995:
ELECTROMAGNETIC COMPATIBILITY. GENERIC IMMUNITY STANDARD. PART 2: INDUSTRIAL ENVIRONMENT
Following the provision of the Directive(s): 89/336 CEE AND SUCCESSIVE AMENDMENTS, 92/31 CEE; 93/68 CEE
Lippo di Calderara, 23.03.1998
Ruggero Cacioppo
Quality Assurance Supervisor