The text of a manual · part 4 of 6
DS41 Installation Manual, pages 31 to 40
Pages 31 to 40 of 55
The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DS-41
Page 31
INSTALLATION
2 DS41
USER INTERFACE 2
TX485+
4
TX485-
3
RX485+
5
RX485-
7
SGND
RX485
TX485
SGND
Figure 17 - RS485 Full Duplex connections
To select this interface type, follow the instructions in paragraphs 2.2 and 2.3.
RS485 Half Duplex Interface The Half Duplex configuration can be used for multidrop connections with a Datalogic multiplexer or it can also be used for a master-slave layout (see paragraph 2.8.1). The following pins of the 25-pin connector are used for RS485 Half Duplex communications:
Pin 2 4 7
Name RTX485+ RTX485SGND
Function RS485 input/output (+) RS485 input/output (-) Signal ground
DS41
MULTIPLEXER 2
RTX485+
4
RTX485-
7
SGND
RTX485+ RTX485RS485REF
Figure 18 - RS485 Half Duplex connections
To select this interface type, follow the instructions in paragraphs 2.2 and 2.3.
19
Page 32
DS41
2
For this interface type, the multidrop address must also be set on the DIP switch as shown in the figure below. Record this information for further setup of the multidrop line.
SW1 SW1
SW2
SW4
SW3
Figure 19 - DIP switch for multidrop address selection
The following table shows the address settings where: Position
Address
1
2
3
4
5
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0
1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16
1 = ON
20
Position
Address
1
2
3
4
5
0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
1 1 1 1 0 0 0 0 1 1 1 1 0 0 0 0
1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0
0 = OFF
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Page 33
INSTALLATION
2
The figure below shows a multidrop configuration with DS41 scanners connected to a Multiplexer.
max. 2 m.
1
DS41
2
#x
4
(up to 31)
7
DS41
2
#1
4
1
120 Ohm
7 max. 1200 m.
CHASSIS
DS41
2
#0
4
1
7
RTX485+ RTX485SGND three wires + shield RTX485+
MULTIPLEXER
RTX485RS485REF SHIELD
120 Ohm Figure 20 - DS41 multidrop connection to a Multiplexer
21
Page 34
DS41
2
20 mA Current Loop Interface The DS41 only supports passive type current loop connections. The following pins of the 25-pin connector are used: Pin
Name
Function
5 3 4 2
CLINCLIN+ CLOUTCLOUT+
Current Loop Input (-) Current Loop Input (+) Current Loop Output (-) Current Loop Output (+)
DS41
USER INTERFACE 5
C.L. IN-
3
C.L. IN+
4
C.L. OUT-
2
C.L. OUT+
I = 20 mA
I = 20 mA
MAX. 300 METERS
Figure 21 - 20 mA C.L. connections
To select this interface type, follow the instructions in paragraphs 2.2 and 2.3.
22
Page 35
INSTALLATION
2.6.3
2
Auxiliary RS232 Interface
The auxiliary serial interface is used exclusively for RS232 point-to-point connections. The parameters relative to the auxiliary interface (baud rate, data bits, etc.) as well as particular operating modes such as local echo can be defined using the WinHost utility program or Host Mode programming. For more details refer to paragraph 2.8 and to the section "Auxiliary Interface Menu" in the WinHost Help On Line. The following pins of the 25-pin connector are used to connect the RS232 auxiliary interface: Pin 20 21 23 24 7
Name RXAUX TXAUX CTSAUX RTSAUX SGND
DS41
Function Auxiliary input Auxiliary output Auxiliary handshake Auxiliary handshake Signal Ground
USER INTERFACE 20
RXAUX TXD
21 TXAUX RXD 23
CTSAUX
24 RTSAUX 7
SGND
DTR DCD SGND
RTS/CTS HARDWARE HANDSHAKING ENABLED
Figure 22 - RS232 auxiliary interface connections
The RTSAUX and CTSAUX signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the DS41 activates the RTSAUX output to indicate a message is to be transmitted. The receiving unit activates the CTSAUX input to enable the transmission.
23
Page 36
DS41
2
Code Verifier If the DS41 is used as a Code Identifier, it is possible to indicate to the scanner what code to store as the verifier code by means of an external hardware input. The Code Verifier parameter must be enabled and the configuration parameters to allow correct Code Type reading must be saved to the scanner in order to read the code verifier. To activate the input, connect together pins 23 and 24 (CTSAUX and RTSAUX) of the 25-pin connector (for example with a push-button), before the active edge of the External Trigger input (or before the code passes under the laser beam for the Automatic operating mode). The next read code will be stored as the verifier code in the scanner's RAM and NON-VOLATILE (EEPROM) memory by default. Then, the two pins must be disconnected. Since it uses part of the RS232 auxiliary serial interface, this interface is limited when using this option and the Handshake selection must not be set to RTS/CTS.
2.6.4
Inputs
The inputs available on the DS41 scanner are the pins relative to the External Trigger, as indicated below: Pin 18 19
Name EXT TRIG+ EXT TRIG-
Function External Trigger (input+) External Trigger (input-)
The inputs indicated are always used to connect the External Trigger which tells the scanner to scan for a code. The yellow led (Figure A, 9) is on during the active phase of the External Trigger signal indicating that decoding can take place. This input is optocoupled and can be driven by both an NPN or PNP type command. The connections are indicated in the following diagrams: DS41
Vext 30 Vdc max.
PRESENCE SENSOR
+ 5V 18 EXT TRIG+
V
19 EXT TRIGSignal
Figure 23 - Input NPN command using external power
24
Page 37
INSTALLATION
2 DS41
PRESENCE SENSOR 9
VS
V
+ 5V 18 EXT TRIG+ 19
EXT TRIG-
25
GND
Signal Ground
Figure 24 - Input NPN command using DS41 power
Vext 30 Vdc max.
PRESENCE SENSOR
DS41
V + 5V 18
EXT TRIG+
19
EXT TRIG-
Signal
Ground
Figure 25 - Input PNP command using external power
DS41
PRESENCE SENSOR 9
VS
18
EXT TRIG+
19
EXT TRIG-
25
GND
+ 5V
V Signal
Figure 26 - Input PNP command using DS41 power
The electrical features are given below: Maximum voltage Maximum current
30 Vdc 25 mA
An anti-disturbance filter is implemented on the External Trigger input with a nominal delay of about 5 milliseconds.
25
Page 38
DS41
2
2.6.5
Outputs
In addition to the pins relative to the communication interfaces as described in the previous paragraphs, the following pins are present on the 25-pin connector of the scanner: Pin 8 22 11 12 14 15
Name NO READ+ NO READRIGHT+ RIGHTWRONG+ WRONG-
Function No read output (+) No read output (-) Right read output (+) Right read output (-) Wrong read output (+) Wrong read output (-)
The NO READ output activates when the code signaled by the External Trigger is not decoded. DS41
USER INTERFACE Vext 40 Vdc max
8
NO READ+
22 NO READ-
Figure 27 - NO READ output connection
The RIGHT output activates when the code is decoded correctly. DS41
USER INTERFACE Vext 40 Vdc max
11
RIGHT+
12
RIGHT-
Figure 28 - RIGHT code output connection
26
Page 39
INSTALLATION
2
The WRONG output is used either for "Verifier" mode or for PCS control. For Verifier this output activates when the decoded code does not correspond to the one set in the configuration. For PCS this output activates when the PCS level is below the threshold value. DS41
USER INTERFACE Vext 40 Vdc max
14
WRONG+
15
WRONG-
Figure 29 - WRONG code output connection
These outputs are all level or pulse programmable: a 50 ms pulse is generated in the second case. Further programming information is supplied in the section "Output Lines" in the WinHost Help On Line.
2.7
POSITIONING
The DS41 scanner is able to decode moving barcode labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting the DS41 take into consideration these three ideal label position angles: Pitch 0° , Skew 10° to 30° and Tilt 0°. Follow the suggestions below for the best orientation: The Pitch angle is represented by the value P in Figure 30. Position the reader in order to minimize the Pitch angle.
27
Page 40
DS41
2 P
Figure 30 - Pitch angle
The Skew angle is represented by the value S in Figure 31. Position the reader to assure at least 10° for the Skew angle. This avoids the direct reflection of the laser light emitted by the DS41. For raster models, this angle refers to the most inclined or external raster line, so that all other raster lines assure more than 10° Skew.
S
Figure 31 - Skew Angle
The Tilt angle is represented by the value T in Figure 32. Position the reader in order to minimize the Tilt angle. T
Figure 32 - Tilt angle
28