Page 21
INSTALLATION
2.5
2
JUNCTION BOX INSTALLATION
DS41
Junction Box provides a passive connection between your scanner and the outside world in a fast and practical way. It represents an alternative to the 25-pin connector models. Figure 5 shows the basic layout of DS41 using the junction box.
Figure 5 - Scanner using Junction Box
For Junction Box connections, the scanner has a cable that terminates in a 24-pin connector that plugs into the junction box. The system cables pass through 6 glands in the side of the Junction Box and the individual wires connect to spring clamp terminal blocks inside which provide access to all scanner signals.
2.5.1
Junction Box Mounting
The diagram below shows the dimensions of the junction box and its relative mounting holes.
mm inch
Figure 6 – Junction Box dimensions
9
Page 22
DS41
2
Junction Box is designed to be mounted to a panel of metal, plastic or other appropriate material using the mounting screws provided in the package. To do this: 1) Open the junction box by unscrewing the 4 cover screws. If necessary, using the two mounting holes inside the junction box as a pattern, mark the panel with an appropriate object and then drill two small pilot holes in the panel. 2) Align the junction box and insert the two self-threading screws with their washers and screw them into the panel until tight (see Figure 7).
Figure 7 - Mounting Junction Box
10
Page 23
INSTALLATION
2.5.2
2
Electrical Connections for Junction Box
The connection and wiring procedure for Junction Box is described as follows: 1) Open the junction box by unscrewing the 4 cover screws. 2) Pass all System cables through the glands in the junction box housing. 3) To connect the power and input/output signals: •
Prepare the individual wires of the system cables by stripping the insulation back approximately 11 mm.
•
Using a device such as a screwdriver, push down on the orange lever directly above the clamp (see Figure 8).
•
Insert the wire into the clamp and release the lever.
The wire will now be held in the spring clamp.
Figure 8 - System cable connections to the junction box
The wiring used can be solid or stranded but must meet the following specifications. Positions 1-4:
24 - 16 AWG
0.2 - 1.5 mm²
Positions 5-39:
26 - 20 AWG
0.14 - 0.5 mm²
The junction box pinouts are indicated in the following table:
11
Page 24
DS41
2 Junction Box pinout for DS41 18
Pin
Name
01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 27 28 34 35 36 37 38 39
VS GND VS GND CHASSIS VS VS EXT TRIG+ EXT TRIGGND GND VS VS n.c. n.c. GND GND NOREAD+ NOREADRIGHT+ RIGHTWRONG+ WRONGn.c. GND GND TXAUX RTSAUX GND RXAUX CTSAUX
CAUTION
12
J1
39
1
5
17
Figure 9 – Junction Box connector and pinout
To allow connection of an NEC Class 2 Power Unit, use a correct female plug adapter. Junction Box NEC Class 2 Power supply
Female Plug System cables Figure 10 - NEC Class 2 Power unit connections
Do not connect GND and SGND to different (external) ground references. GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
Page 25
INSTALLATION
Pin
2 RS232
24*, 29 25*, 30 26*, 31 32 33
TX232 RTS232 SGND RX232 CTS232
RS485 full-duplex TX485+ TX485SGND RX485+ RX485-
RS845 half-duplex RTX485+ RTX485SGND
20 mA CL CLOUT+ CLOUTCLIN+ CLIN-
*
The signals on pins 24, 25, and 26 are repeated on pins 29, 30, and 31 to facilitate network connections (i.e. Multiplexer connections using the RS485 half duplex Interface). In this way the network bus can enter and exit the junction box from different spring clamps but be physically connected together.
4)
After wiring the junction box and while the scanner is unplugged from the power supply, place the Scanner cable so that the rubber seal fits into the cutout in the housing of the junction box and plug the 24-pin connector into connector J1 on the PCB inside the junction box as shown in Figure 11.
Rubber seal
J1
Scanner cable
Figure 11 - Scanner cable connections to the junction box
5) Close the junction box using the 4 cover screws making sure the rubber seal is fitted correctly between the parts of the housing. The junction box is now installed which completes the electrical connections for your scanning system. If it ever becomes necessary to disconnect the scanner from the Junction Box, simply reverse the procedure in step 4.
13
Page 26
DS41
2
2.6
ELECTRICAL CONNECTIONS FOR 25-PIN MODELS
DS41 25-pin connector models (see paragraph 1.3) are equipped with a cable terminated by a 25-pin D-sub connector for connection to the power supply and input/output signals. The details of the connector pins are indicated in the following table:
CAUTION
Do not connect GND and SGND to different (external) ground references. GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
Figure 12 - 25-pin D-sub connector
25-pin D-sub connector pinout Pin 13 25 1 9 18 19 8 22 11 12 14 15 20 21 23 24 6, 10, 16, 17
Name
Function
VS GND CHASSIS VS EXT TRIG+ EXT TRIGNO READ + NO READ RIGHT + RIGHT WRONG + WRONG RXAUX TXAUX CTSAUX RTSAUX NC
Power supply input voltage (+) Power supply input voltage (-) Chassis Ground External Trigger supply voltage (+) External Trigger (+) External Trigger (-) No read output (+) No read output (-) Right read output (+) Right read output (-) Wrong read output (+) Wrong read output (-) Auxiliary input Auxiliary output Auxiliary handshake Auxiliary handshake No Connect
RS232 2* 3* 4* 5* 7 *
14
TX232 RX232 See par. 2.3 RTS232 and 2.4. CTS232 SGND
RS485 full-duplex
RS485 half-duplex
TX485+ RX485TX485RX485SGND
RTX485+ RTX485-
20 mA CL CLOUT+ CLIN+ CLOUTCLIN-
SGND
Pins 2, 3, 4, and 5 of the 25-pin connector have different meanings depending on which interface type is selected. To select the interface type, follow the instructions in paragraphs 2.2 and 2.3.
Page 27
INSTALLATION
2.6.1
2
Power Supply
Power can be supplied to the scanner through the pins provided on the 25-pin connector used for communication with the host (Figure 13):
USER INTERFACE
DS41 13
V+ (10 - 30 Vdc)
VS 25
GND
GND CHASSIS
1
Earth Ground
CHASSIS
Figure 13 - Power supply connections or through the jack connector on the side of the 25-pin connector for connections to a UL Listed Direct Plug-in Power Unit (Figure 14). If the jack input is used to supply power to the DS41, pin 13 is automatically disconnected; the supply voltage for the External Trigger remains on pin 9. The plug connector is not supplied with the DS41.
GND Jack
Plug
V+ (10 - 30 Vdc)
Figure 14 - Power supplied using the jack connector
The power must be between 10 and 30 Vdc only. There is a current peak of about 1A at 10 V during power on caused by the motor starting. It is recommended to connect pin 1 (CHASSIS) to a common earth ground.
15
Page 28
DS41
2
2.6.2
Main Serial Interface
The signals relative to the following serial interface types are available on the input/output connector: RS232 RS485 FULL DUPLEX RS485 HALF DUPLEX (for connection with a Datalogic multiplexer) 20 mA PASSIVE CURRENT LOOP
DS41 automatically recognizes the type of interface selected at each power on of the scanner. If the recognized interface type is not compatible with the current communication handshaking, then the system forces the XON/XOFF protocol. The parameters relative to the interface selected (baud rate, data bits, etc.) can be configured using the WinHost utility program or Host Mode programming. For more details refer to the section "Main Interface Menu" in the WinHost Help On Line. Details regarding the connections and use of the main interface selection are given in the next paragraphs.
16
Page 29
INSTALLATION
2
RS232 Interface The serial interface is used in this case for point-to-point connections; it handles communication with the host computer and allows both transmission of code data and the configuration of the scanner. This is the default interface. The following pins of the 25-pin connector are used for RS232 interface connection:
Pin 2 3 4 5 7
Name TX232 RX232 RTS232 CTS232 SGND
Function Transmitted data Received data Request to send Clear to send Signal ground
DS41
USER INTERFACE 2
TX232
3
RX232
4
RTS232
5
CTS232
7
SGND
RXD TXD DCD DTR SGND
RTS/CTS HARDWARE HANDSHAKING ENABLED Figure 15 - RS232 main interface connections
17
Page 30
DS41
2
Figure 16 - RS232 control signals
The RTS232 and CTS232 signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the DS41 activates the RTS232 output to indicate a message is to be transmitted. The receiving unit activates the CTS232 input to enable the transmission.
RS485 Full Duplex Interface The Full Duplex configuration is used for point-to-point connections over longer distances than those acceptable for RS232 communications or in electrically noisy environments. The following pins of the 25-pin connector are used for RS485 Full Duplex communications:
Pin 2 4 3 5 7
18
Name TX485+ TX485RX485+ RX485SGND
Function RS485 output (+) RS485 output (-) RS485 input (+) RS485 input (-) Signal Ground