Page 31

INSTALLATION

2

The RTSAUX and CTSAUX signals control data transmission and synchronize the connected devices. If the RTS/CTS handshaking protocol is enabled, the DS2400 activates the RTSAUX output to indicate a message is to be transmitted. The receiving unit activates the CTSAUX input to enable the transmission.

Code Verifier If the DS2400 is used as a Code Verifier, it is possible to indicate to the scanner what code to store as the verifier code by means of an external hardware input. The Code Verifier parameter must be enabled and the configuration parameters to allow correct Code Type reading must be saved to the scanner in order to read the verifier code. To activate the input, connect together pins 23 and 24 (CTSAUX and RTSAUX) of the 25-pin connector (for example with a push-button), before the active edge of the External Trigger input (or before the code passes under the laser beam for the Automatic operating mode. The next read code will be stored as the verifier code in the scanner's RAM and NON-VOLATILE (EEPROM) memory by default. Then the two pins must be disconnected. Since it uses part of the RS232 auxiliary serial interface, this interface is limited when using this option and the Handshake selection must not be set to RTS/CTS.

2.4.4

Inputs

The inputs available on the connector supplied with the scanner are the pins relative to the External Trigger, as indicated below: Pin

Name

Function

18 19

EXT TRIG+ EXT TRIG- external trigger + external trigger -

The External Trigger input is used in the On-Line Operating Mode and tells the scanner to scan for a code. The active state of this input is selected in software. Refer to the WinHost Help On Line. The yellow LED (Figure A, 2) is on when the External Trigger forces a current flow through the EXT TRIG+ and EXT TRIG- pins.

19

Page 32

DS2400

2

This input is optocoupled and can be driven by both an NPN or PNP type command. The connections are indicated in the following diagrams: DS2400 + 5V

Vext 18

EXT TRIG+

19

EXT TRIG-

30 Vdc max. EXTERNAL TRIGGER V

Signal

Figure 20 - Input NPN command using external power DS2400

EXTERNAL TRIGGER VS

9 + 5V

V

18 EXT TRIG+ 19 EXT TRIG25

Signal

GND

Ground

Figure 21 - Input NPN command using DS2400 power Vext 30 Vdc max.

DS2400

EXTERNAL TRIGGER V

+ 5V

Signal

18 EXT TRIG+ 19

EXT TRIG-

Ground

Figure 22 - Input PNP command using external power EXTERNAL TRIGGER

DS2400 9 + 5V

VS

18

EXT TRIG+

19

EXT TRIG-

25

GND

V Signal

Ground

Figure 23 - Input PNP command using DS2400 power

20

Page 33

INSTALLATION

2

Electrical features:

Maximum voltage: Maximum current:

30 Vdc 25 mA

An anti-disturbance hardware filter is implemented on the External Trigger input (about 1 millisecond delay). An additional 15 ms (typical) delay can be implemented through a dedicated software parameter (refer to WinHost Help On Line).

2.4.5

Outputs

Two general purpose outputs are available. These outputs can only be connected as open collector configurations. The following pins are present on the 25-pin connector of the scanner: Pin

Name

Function

8 11 12, 22

OUT1+ OUT2+ OUT REF output 1 + output 2 + output reference

DS2400

USER INTERFACE 8/11

OUT1+ / OUT2+

12/22

OUT REF

Vext 40 Vdc max

Figure 24 - Output connections

The meaning of the two outputs OUT1 and OUT2 can be defined by the user. Refer to the WinHost Help On Line. By default, OUT1 is associated with the No Read event, which activates when the code signaled by the external trigger is not decoded, and OUT2 is associated with the Right event, which activates when the code is correctly decoded. These outputs are both level or pulse configurable.

21

Page 34

DS2400

2

2.5

POSITIONING

The DS2400 scanner is able to decode moving barcode labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting the DS2400 take into consideration these three ideal label position angles: Pitch 0°, Skew 10° to 30° and Tilt 0°. Follow the suggestions for the best orientation: The Pitch angle is represented by the value P in Figure 25. Position the reader in order to minimize the Pitch angle.

Figure 25 - Pitch Angle

The Skew angle is represented by the value S in Figure 26. Position the reader to assure at least 10° for the Skew angle. This avoids the direct reflection of the laser light emitted by the DS2400. For the raster version, this angle refers to the most inclined or external raster line, so that all other raster lines assure more than 10° Skew.

Figure 26 - Skew angle

22

Page 35

INSTALLATION

2

The Tilt angle is represented by the value T in Figure 27. Position the reader in order to minimize the Tilt angle.

Figure 27 - Tilt angle

2.6

TYPICAL LAYOUTS

The following typical layouts refer to system hardware configurations. Dotted lines in the figures refer to optional hardware configurations within the particular layout. These layouts also require the correct setup of the software configuration parameters. Complete software configuration procedures can be found in the Guide To Rapid Configuration in the WinHost Help On Line.

23

Page 36

DS2400

2

2.6.1

Point-to-Point

In this layout the data is transmitted to the Host on the main serial interface. Host Mode programming can be accomplished either through the main interface or the auxiliary interface. In Local Echo communication mode, data is transmitted on the RS232 auxiliary interface independently from the main interface selection. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.

2

Figure 28 - Point-to-Point layout

24

PWR/TXD

3 External Trigger (for On-Line mode)

EXT TRIG

1 Main serial interface 2 Auxiliary serial interface (Local Echo)

LASER ON

3

DS2400

DS2400

Host

GOOD READ

Terminal

1

Page 37

INSTALLATION

2.6.2

2

Pass Through

Pass through mode allows two or more devices to be connected to a single external serial interface. Each DS2400 transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the host. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone. The main and auxiliary ports are connected as shown in the figure below: 1 Main serial interface 2 Auxiliary serial interface 3 External Trigger (for On-Line mode) 1

2

EXT TRIG

PWR/TXD

LASER O N

DS2400

DS2400

GO OD READ

EXT TRIG

PWR/TXD

LASER ON

DS2400

GOO D READ

1

DS2400

Host

3

3

Figure 29 - Pass through layout

25

Page 38

DS2400

2

2.6.3

RS232 Master/Slave

The RS232 master/slave connection is used to collect data from several scanners to build either an multi-point or a multi-sided reading system; there can be one master and up to 9 slaves connected together. The Slave scanners use RS232 only on the main and auxiliary serial interfaces. Each slave DS2400 transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the master. The master scanner is connected to the Host on the main serial interface. The possible main interface types for the Master scanner are RS232 or RS485. (20 mA C.L. can also be used if the INT-22 accessory is installed). Either On-Line or Serial On-Line Operating modes can be used in this layout. When On-Line Operating mode is used, the external trigger signal is unique to the system, however it is not necessary to bring the external trigger signal to the Slave scanners. The main and auxiliary ports are connected as shown in the figure below.

2

1 2

PWR/TXD

E XT T R IG

LASER ON

DS2400

GOOD READ

DS2400 Slave

DS2400 Slave DS2400 L AS E R O N G O O D REA D

P W R /T XD

E XT T R I G

EXT TRIG

P W R / TX D

G O O D REA D L AS E R O N

DS2400

1 3

1 Main serial interface 2 Auxiliary serial interface 3 External Trigger (for On-Line mode) Figure 30 - RS232 Master/Slave layout

26

Host

DS2400 Master

1

Page 39

INSTALLATION

2.6.4

2

RS485 Master/Slave

The RS485 master/slave connection is used to collect data from several scanners to build either a multi-point or a multi-sided reading system; there can be one master and up to 5 slaves connected together. The slave scanners are connected together using RS485 half-duplex on the main serial interface. Every slave scanner must have a multidrop address in the range 0-4. The master scanner is also connected to the Host on the RS232 auxiliary serial interface. The External Trigger signal is unique to the system; there is a single reading phase and a single message from the master scanner to the Host computer. It is necessary to bring the External Trigger signal to all the scanners. The main and auxiliary ports are connected as shown in the figure below.

1 Auxiliary serial interface 2 RS485HD Main serial interface

Host 1

3 External Trigger

2 1 EXT T RIG

PWR/TXD

L ASER ON

DS2400

GOOD READ

DS2400 Slave

DS2400 Slave DS2400 LAS ER ON PWR/TXD

GOOD READ

EXT TRIG

EX T TRIG

GOOD READ

PWR/T XD

LAS ER ON

DS2400

1

DS2400 Master

3 Figure 31 - RS485 Master/Slave layout

27

Page 40

DS2400

2

The auxiliary serial interface of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode Programming procedure. NOTE

2.6.5

The termination resistors of the RS485 bus must not be installed.

Multiplexer

Each scanner is connected to Multiplexer (for example MX4000) with the RS485 halfduplex main interface. 0

31 E XT T R IG

PW R /T XD

L AS E R O N

3

DS2400

2

GO O D R E AD

P W R /TX D

E XT TR I G

LA S E R O N

1

DS2400

3

2

G O OD R E AD

EXT T R IG

P WR / TXD

L AS ER ON

D S24 00

GO OD R E AD

2

1

3

Host 1 RS485 HD Main interface

MX4000

2 Auxiliary interface (Local Echo) 3 External Trigger (for On-Line mode) Figure 32 - Multiplexer layout

The auxiliary serial interface of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode Programming procedure. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.

28