Page 21

INSTALLATION

2.3.2

2

Junction Box Electrical Connections

The connection and wiring procedure for Junction Box is described as follows: 1) Open the junction box by unscrewing the 4 cover screws. 2) Pass all System cables through the glands in the junction box housing. 3) To connect the power and input/output signals: • • •

Prepare the individual wires of the system cables by stripping the insulation back approximately 11 mm. Using a device such as a screwdriver, push down on the orange lever directly above the clamp (see Figure 7). Insert the wire into the clamp and release the lever.

The wire will now be held in the spring clamp.

Figure 7 - System cable connections to the junction box

The wiring used can be solid or stranded but must meet the following specifications: Positions 1-4: 24 - 16 AWG 0,2 - 1,5 mm2 Positions 5-39: 26 - 20 AWG 0,14 - 0,5 mm2 The junction box pinouts are indicated in the following table:

9

Page 22

DS2400

2 J. Box Pinout for DS2400 Pin Name 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 *24 *25 *26 27 28 29 30 31 32 33 34 35 36 37 38 39

N.C. GND Main interface signals see table on next page

J1

39

1

5

17

Figure 8 - Junction Box connector and pinout To allow connection of an NEC Class 2 Power Unit, use a correct female plug adapter.

Junction Box NEC Class 2 Power supply

Female Plug System cables Figure 9 - NEC Class 2 Power unit connections

*

The signals on pins 24, 25, and 26 are repeated on pins 29, 30, and 31 to facilitate network connections (i.e. Multiplexer using the RS485 Halfduplex interface). In this way the network bus can enter and exit the junction box from different spring clamps but be physically connected together.

GND TXAUX RTSAUX GND RXAUX CTSAUX

CAUTION

10

18

VS GND VS GND CHASSIS VS VS EXT TRIG + EXT TRIG GND GND VS VS N.C. N.C. GND GND OUT1 + OUT REF OUT2 + N.C. N.C. N.C. Main interface signals see table on next page

Do not connect GND and SGND to different (external) ground references. GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.

Page 23

INSTALLATION

Pin 24,29 25,30 26,31 32 33

2 RS232

TX232 RTS232 SGND RX232 CTS232

RS485 Full-Duplex TX485+ TX485SGND RX485+ RX485-

RS485 Half-Duplex RTX485+ RTX485SGND

20 mA C.L. (INT-22 Only) CL OUT+ CL OUTCL IN+ CL IN-

4) After wiring the junction box and while the scanner is unplugged from the power, place the Scanner cable so that the rubber seal fits into the cutout in the housing of the junction box and plug the 24-pin connector into connector J1 on the PCB inside the junction box as shown in Figure 10.

Rubber seal

J1

Scanner cable

Figure 10 - Scanner cable connections to the junction box

5) Close the junction box using the 4 cover screws making sure the rubber seal is fitted correctly between the parts of the housing. The junction box is now installed which completes the electrical connections for your scanning system. If it ever becomes necessary to disconnect the scanner from the Junction Box, simply reverse the procedure in step 4.

11

Page 24

DS2400

2

2.4

ELECTRICAL CONNECTIONS

DS2400 25-pin connector models are equipped with a cable terminated by a 25-pin female D-sub connector for connection to the power supply and input/output signals. The details of the connector pins are indicated in the following table:

CAUTION

Do not connect GND and SGND to different (external) ground references. GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.

Figure 11 - 25-pin female D-sub connector 25-pin D-sub connector pinout Pin 13 25 1 9 18 19 8 11 12, 22 20 21 23 24 6, 10, 14, 15, 16, 17

Name

Function

VS GND CHASSIS VS EXT TRIG+ EXT TRIGOUT1 + OUT2 + OUT REF RXAUX TXAUX CTSAUX RTSAUX NC

Power supply input voltage + Power supply input voltage Chassis Ground External Trigger supply voltage + External Trigger + External Trigger Output 1 + Output 2 + Output reference Auxiliary RS232 Auxiliary RS232 Auxiliary handshake RS232 Auxiliary handshake RS232 Not Connected

Pin 2 3 4 5 7

12

RS232 Main interface signals, see par. 2.4.2.

TX232 RX232 RTS232 CTS232 SGND

RS485 Full-Duplex

RS485 Half-Duplex

20 mA C.L. (INT-22 Only)

TX485+ RX485+ TX485RX485SGND

RTX485+

CLOUT+ CLIN+ CLOUTCLIN-

RTX485SGND

Page 25

INSTALLATION

2.4.1

2

Power Supply

Power can be supplied to the scanner through the pins provided on the 25-pin connector used for communication with the host: USER INTERFACE

DS2400 13

VS V+ (10 - 30 Vdc)

25 1

GND

VGND

CHASSIS

CHASSIS

Earth Ground

Figure 12 - Power supply connections

The power must be between 10 and 30 Vdc only. It is recommended to connect pin 1 (CHASSIS) to a common earth ground.

2.4.2

Main Serial Interface

The signals relative to the following serial interface types are available on the input/output connector of DS2400 depending on the DS2400 model (see par. 1.3). If the interface type is not compatible with the current communication handshaking, then the system forces the handshake to none. The parameters relative to the interface selected (baud rate, data bits, etc.) can be defined using the WinHost utility program or "Host Mode" programming procedure through ESC sequences provided on diskette. Details regarding the connections and use of the interfaces are given in the next paragraphs.

13

Page 26

DS2400

2

RS232 Interface The serial interface is used in this case for point to point connections; it handles communication with the host computer and allows both transmission of code data and the programming of the scanner. This is the default setting. The following pins are used for RS232 interface connection: Pin

Name

Function

2 3 4 5 7

TX232 RX232 RTS232 CTS232 SGND transmit data receive data request to send clear to send signal ground

DS2400

USER INTERFACE 2

TX232

3

RX232

TXD

4

RTS232

DCD

5

CTS232

DTR

7

SGND

RXD

SGND

Figure 13 – RS232 main interface connections using hardware handshaking

The RTS232 and CTS232 signals control data transmission and synchronize the connected devices.

14

Page 27

INSTALLATION

2

+V RTS -V

START OF TRANSMISSION

END OF TRANSMISSION

DATA TRANSMISSION

DATA TRANSMISSION

+V TX DATA -V

C1 C2

C3

C4

C5

TRANSMISSION STOPPED ENABLED

+V CTS -V

ENABLED

DISABLED

IDLE

IDLE

Figure 14 - RS232 control signals

If the RTS/CTS handshaking protocol is enabled, the DS2400 activates the RTS232 output to indicate a message is to be transmitted. The receiving unit activates the CTS232 input to enable the transmission.

RS485 Full-Duplex Interface The RS485 full-duplex interface is used for non-polled communication protocols in point to point connections over longer distances than those acceptable for RS232 communications or in electrically noisy environments. The connector pinout follows: Pin

Name

Function

2 4 3 5 7

TX485+ TX485RX485+ RX485SGND

RS485 transmit data + RS485 transmit data – RS485 receive data + RS485 receive data signal ground

15

Page 28

DS2400

2 DS2400

USER INTERFACE 2

TX485+

4

TX485-

3

RX485+

5

RX485-

7

SGND

+ RX485 + TX485 +

SGND

Figure 15 - RS485 full-duplex connections

RS485 Half-Duplex Interface The RS485 half-duplex (3 wires + shield) interface is used for polled communication protocols. It can be used in a master/slave layout or for Multidrop connections with a Datalogic Multiplexer, (see par. 2.6.4 and 2.6.5). The connector pinout follows: Pin

Name

Function

2 4 7

RTX485+ RTX485SGND

RS485 transmit/receive data + RS485 transmit/receive data signal ground

DS2400

MULTIPLEXER 2

RTX485 +

4

RTX485 -

7

SGND

RTX485 + RTX485 RS485REF

Figure 16 - RS485 half-duplex connections

This interface is forced by software when the protocol selected is MUX32 protocol. In a Multiplexer layout or for slaves, the Multidrop address must also be set via serial channel by the WinHost utility or by ESC sequences.

16

Page 29

INSTALLATION

2

Figure 17 shows a multidrop configuration with DS2400 scanners connected to a Multiplexer. 120 Ohm max 2 m DS2400 #x (up to 31)

max 1200 m

DS2400 #1 RTX485 +

DS2400 #0

RTX485 SGND

Three wires + shield

CHASSIS

RTX485 + RTX485 MULTIPLEXER

RS485 REF SHIELD

120 Ohm Figure 17 - DS2400 Multidrop connection to a Multiplexer

20 mA Current Loop Interface (INT-22 Accessory Only) When the INT-22 accessory board is installed, the DS2400 is equipped with a 20 mA passive current loop interface. The following pins of the 25-pin connector are used: Pin

Name

Function

5 3 4 2

CLINCLIN+ CLOUTCLOUT+ current loop input current loop input + current loop output current loop output +

17

Page 30

DS2400

2 DS2400

USER INTERFACE 5

C.L. IN-

3

C.L. IN+

4

C.L. OUT-

2

C.L. OUT+

I = 20 mA

I = 20 mA

MAX. 300 METERS

Figure 18 - 20 mA C.L. connections

2.4.3

Auxiliary RS232 Interface

The auxiliary serial interface is used exclusively for RS232 point to point connections. The parameters relative to the aux interface (baud rate, data bits, etc.) as well as particular operating modes such as LOCAL ECHO can be defined using the WinHost utility program installed from the diskette or "Host Mode" programming provided on diskette. The following pins of the 25-pin connector are used to connect the RS232 auxiliary interface: Pin

Name

Function

20 21 23 24 7

RXAUX TXAUX CTSAUX RTSAUX SGND receive data transmit data clear to send request to send signal ground

DS2400

USER INTERFACE 20 RXAUX 21 TXAUX 23 CTSAUX 24 RTSAUX 7

SGND

TXD RXD DTR DCD SGND

Figure 19 - RS232 auxiliary interface connections using hardware handshaking

18