Page 21
INSTALLATION
2.3.2
2
Junction Box Electrical Connections
The connection and wiring procedure for Junction Box is described as follows: 1) Open the junction box by unscrewing the 4 cover screws. 2) Pass all System cables through the glands in the junction box housing. 3) To connect the power and input/output signals: • • •
Prepare the individual wires of the system cables by stripping the insulation back approximately 11 mm. Using a device such as a screwdriver, push down on the orange lever directly above the clamp (see Figure 7). Insert the wire into the clamp and release the lever.
The wire will now be held in the spring clamp.
Figure 7 - System cable connections to the junction box
The wiring used can be solid or stranded but must meet the following specifications: Positions 1-4: 24 - 16 AWG 0,2 - 1,5 mm2 Positions 5-39: 26 - 20 AWG 0,14 - 0,5 mm2 The junction box pinouts are indicated in the following table:
9
Page 22
DS2400
2 J. Box Pinout for DS2400 Pin Name 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 *24 *25 *26 27 28 29 30 31 32 33 34 35 36 37 38 39
N.C. GND Main interface signals see table on next page
J1
39
1
5
17
Figure 8 - Junction Box connector and pinout To allow connection of an NEC Class 2 Power Unit, use a correct female plug adapter.
Junction Box NEC Class 2 Power supply
Female Plug System cables Figure 9 - NEC Class 2 Power unit connections
*
The signals on pins 24, 25, and 26 are repeated on pins 29, 30, and 31 to facilitate network connections (i.e. Multiplexer using the RS485 Halfduplex interface). In this way the network bus can enter and exit the junction box from different spring clamps but be physically connected together.
GND TXAUX RTSAUX GND RXAUX CTSAUX
CAUTION
10
18
VS GND VS GND CHASSIS VS VS EXT TRIG + EXT TRIG GND GND VS VS N.C. N.C. GND GND OUT1 + OUT REF OUT2 + N.C. N.C. N.C. Main interface signals see table on next page
Do not connect GND and SGND to different (external) ground references. GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
Page 23
INSTALLATION
Pin 24,29 25,30 26,31 32 33
2 RS232
TX232 RTS232 SGND RX232 CTS232
RS485 Full-Duplex TX485+ TX485SGND RX485+ RX485-
RS485 Half-Duplex RTX485+ RTX485SGND
20 mA C.L. (INT-22 Only) CL OUT+ CL OUTCL IN+ CL IN-
4) After wiring the junction box and while the scanner is unplugged from the power, place the Scanner cable so that the rubber seal fits into the cutout in the housing of the junction box and plug the 24-pin connector into connector J1 on the PCB inside the junction box as shown in Figure 10.
Rubber seal
J1
Scanner cable
Figure 10 - Scanner cable connections to the junction box
5) Close the junction box using the 4 cover screws making sure the rubber seal is fitted correctly between the parts of the housing. The junction box is now installed which completes the electrical connections for your scanning system. If it ever becomes necessary to disconnect the scanner from the Junction Box, simply reverse the procedure in step 4.
11
Page 24
DS2400
2
2.4
ELECTRICAL CONNECTIONS
DS2400 25-pin connector models are equipped with a cable terminated by a 25-pin female D-sub connector for connection to the power supply and input/output signals. The details of the connector pins are indicated in the following table:
CAUTION
Do not connect GND and SGND to different (external) ground references. GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
Figure 11 - 25-pin female D-sub connector 25-pin D-sub connector pinout Pin 13 25 1 9 18 19 8 11 12, 22 20 21 23 24 6, 10, 14, 15, 16, 17
Name
Function
VS GND CHASSIS VS EXT TRIG+ EXT TRIGOUT1 + OUT2 + OUT REF RXAUX TXAUX CTSAUX RTSAUX NC
Power supply input voltage + Power supply input voltage Chassis Ground External Trigger supply voltage + External Trigger + External Trigger Output 1 + Output 2 + Output reference Auxiliary RS232 Auxiliary RS232 Auxiliary handshake RS232 Auxiliary handshake RS232 Not Connected
Pin 2 3 4 5 7
12
RS232 Main interface signals, see par. 2.4.2.
TX232 RX232 RTS232 CTS232 SGND
RS485 Full-Duplex
RS485 Half-Duplex
20 mA C.L. (INT-22 Only)
TX485+ RX485+ TX485RX485SGND
RTX485+
CLOUT+ CLIN+ CLOUTCLIN-
RTX485SGND
Page 25
INSTALLATION
2.4.1
2
Power Supply
Power can be supplied to the scanner through the pins provided on the 25-pin connector used for communication with the host: USER INTERFACE
DS2400 13
VS V+ (10 - 30 Vdc)
25 1
GND
VGND
CHASSIS
CHASSIS
Earth Ground
Figure 12 - Power supply connections
The power must be between 10 and 30 Vdc only. It is recommended to connect pin 1 (CHASSIS) to a common earth ground.
2.4.2
Main Serial Interface
The signals relative to the following serial interface types are available on the input/output connector of DS2400 depending on the DS2400 model (see par. 1.3). If the interface type is not compatible with the current communication handshaking, then the system forces the handshake to none. The parameters relative to the interface selected (baud rate, data bits, etc.) can be defined using the WinHost utility program or "Host Mode" programming procedure through ESC sequences provided on diskette. Details regarding the connections and use of the interfaces are given in the next paragraphs.
13
Page 26
DS2400
2
RS232 Interface The serial interface is used in this case for point to point connections; it handles communication with the host computer and allows both transmission of code data and the programming of the scanner. This is the default setting. The following pins are used for RS232 interface connection: Pin
Name
Function
2 3 4 5 7
TX232 RX232 RTS232 CTS232 SGND transmit data receive data request to send clear to send signal ground
DS2400
USER INTERFACE 2
TX232
3
RX232
TXD
4
RTS232
DCD
5
CTS232
DTR
7
SGND
RXD
SGND
Figure 13 – RS232 main interface connections using hardware handshaking
The RTS232 and CTS232 signals control data transmission and synchronize the connected devices.
14
Page 27
INSTALLATION
2
+V RTS -V
START OF TRANSMISSION
END OF TRANSMISSION
DATA TRANSMISSION
DATA TRANSMISSION
+V TX DATA -V
C1 C2
C3
C4
C5
TRANSMISSION STOPPED ENABLED
+V CTS -V
ENABLED
DISABLED
IDLE
IDLE
Figure 14 - RS232 control signals
If the RTS/CTS handshaking protocol is enabled, the DS2400 activates the RTS232 output to indicate a message is to be transmitted. The receiving unit activates the CTS232 input to enable the transmission.
RS485 Full-Duplex Interface The RS485 full-duplex interface is used for non-polled communication protocols in point to point connections over longer distances than those acceptable for RS232 communications or in electrically noisy environments. The connector pinout follows: Pin
Name
Function
2 4 3 5 7
TX485+ TX485RX485+ RX485SGND
RS485 transmit data + RS485 transmit data – RS485 receive data + RS485 receive data signal ground
15
Page 28
DS2400
2 DS2400
USER INTERFACE 2
TX485+
4
TX485-
3
RX485+
5
RX485-
7
SGND
+ RX485 + TX485 +
SGND
Figure 15 - RS485 full-duplex connections
RS485 Half-Duplex Interface The RS485 half-duplex (3 wires + shield) interface is used for polled communication protocols. It can be used in a master/slave layout or for Multidrop connections with a Datalogic Multiplexer, (see par. 2.6.4 and 2.6.5). The connector pinout follows: Pin
Name
Function
2 4 7
RTX485+ RTX485SGND
RS485 transmit/receive data + RS485 transmit/receive data signal ground
DS2400
MULTIPLEXER 2
RTX485 +
4
RTX485 -
7
SGND
RTX485 + RTX485 RS485REF
Figure 16 - RS485 half-duplex connections
This interface is forced by software when the protocol selected is MUX32 protocol. In a Multiplexer layout or for slaves, the Multidrop address must also be set via serial channel by the WinHost utility or by ESC sequences.
16
Page 29
INSTALLATION
2
Figure 17 shows a multidrop configuration with DS2400 scanners connected to a Multiplexer. 120 Ohm max 2 m DS2400 #x (up to 31)
max 1200 m
DS2400 #1 RTX485 +
DS2400 #0
RTX485 SGND
Three wires + shield
CHASSIS
RTX485 + RTX485 MULTIPLEXER
RS485 REF SHIELD
120 Ohm Figure 17 - DS2400 Multidrop connection to a Multiplexer
20 mA Current Loop Interface (INT-22 Accessory Only) When the INT-22 accessory board is installed, the DS2400 is equipped with a 20 mA passive current loop interface. The following pins of the 25-pin connector are used: Pin
Name
Function
5 3 4 2
CLINCLIN+ CLOUTCLOUT+ current loop input current loop input + current loop output current loop output +
17
Page 30
DS2400
2 DS2400
USER INTERFACE 5
C.L. IN-
3
C.L. IN+
4
C.L. OUT-
2
C.L. OUT+
I = 20 mA
I = 20 mA
MAX. 300 METERS
Figure 18 - 20 mA C.L. connections
2.4.3
Auxiliary RS232 Interface
The auxiliary serial interface is used exclusively for RS232 point to point connections. The parameters relative to the aux interface (baud rate, data bits, etc.) as well as particular operating modes such as LOCAL ECHO can be defined using the WinHost utility program installed from the diskette or "Host Mode" programming provided on diskette. The following pins of the 25-pin connector are used to connect the RS232 auxiliary interface: Pin
Name
Function
20 21 23 24 7
RXAUX TXAUX CTSAUX RTSAUX SGND receive data transmit data clear to send request to send signal ground
DS2400
USER INTERFACE 20 RXAUX 21 TXAUX 23 CTSAUX 24 RTSAUX 7
SGND
TXD RXD DTR DCD SGND
Figure 19 - RS232 auxiliary interface connections using hardware handshaking
18