The text of a manual · part 2 of 5
DS2400 Installation Manual, pages 11 to 20
Pages 11 to 20 of 49
The original document is the PDF (3.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DS-2400
Page 11
POWER SUPPLY - This product is intended to be installed by Qualified Personnel only. - Models DS2400-XXX0: This accessory device is intended to be supplied by a UL Listed Power Unit with «Class 2» or LPS power source which supplies power directly to the scanner via the 25-pin connector. - Model DS2400-XXX1: This accessory device is intended to be supplied via the Junction Box by an NEC Class 2 Power Source rated 10-30 V, minimum 0.55 A.
ix
Page 12
x
Page 13
GENERAL FEATURES
1
1 GENERAL FEATURES 1.1
INTRODUCTION
The DS2400 laser scanner satisfies the most advanced needs of a wide range of users. It has been developed focusing on the realistic requirements of its target market. The outstanding result is an extremely compact, cost-effective and easy to use industrial scanner. C-Programmability
The DS2400 belongs to the generation of Datalogic scanners that operate under the 'C' programming environment, which is a recognized industry standard.
Standard Application Program
A standard application program is factory-loaded onto the DS2400. This program controls barcode reading, serial port interfacing, data formatting and many other operating and control parameters. It is completely configurable from a host computer through the WinHost utility program provided on diskette with the scanner, or through ESC sequences via the serial interface.
Custom Application Programs
If the Standard Application Program does not meet your requirements, please contact your local Datalogic distributor.
1
Page 14
DS2400
1
1.2
DESCRIPTION
Some of the main features of DS2400 are listed below: • small dimensions and light weight.
• software programmable scanning speed (400 to 1000 scans/sec) on all models.
• linear and raster versions.
• connector and junction box versions.
• completely configurable via serial interface (WinHost).
•
2 serial communication interfaces.
• supply voltage from 10 to 30 Vdc.
• reads all popular codes.
• test mode to verify the reading features and exact positioning of the scanner without the need for external tools.
• programmable in 4 different operating modes to suit the most various barcode reading system requirements.
• code verifier.
The DS2400 uses a solid state laser diode as a light source; the light emitted has a wavelength between 630 and 680 nm. Refer to the section “Safety precautions” at the beginning of this manual for information on laser safety. The protection class of the enclosure is IP65, the reader is therefore suitable for industrial environments where high protection against harsh external conditions is required. The four LEDs on the side of the scanner indicate the following: PWR/TXD
LED (red) (Figure A, 1) indicates the reader is connected to the power supply or, when blinking (green), data transmission.
GOOD READ
LED (red) (Figure A, 3) is used to signal the possibility of a successful barcode reading.
EXT TRIG
LED (yellow) (Figure A, 2) indicates external trigger activity. Refer to par. 2.4.4.
LASER ON
LED (green) (Figure A, 4) indicates laser ON state.
The screw holes on the body of the reader are for mechanical fixture (Figure A, 8).
2
Page 15
GENERAL FEATURES
1.3
1
AVAILABLE MODELS
The DS2400 scanner is available in versions that differ in regard to the following parameters: •
Reading range
•
Serial interfaces
•
Linear or raster reading
•
Connections
The following models are therefore available:
DS2400 - X X X X Reading Range
Connections
1 = Medium range 2 = Long range
0 = Connector 1 = Junction Box
Serial Communication Interface
Linear/Raster
0 = RS232 main + RS232 aux 1 = RS485 main + RS232 aux
0 = Linear 1 = Raster
The following tables display each version’s reading performance.
Version 1XXX 2XXX
Version
Max Code Resolution
Speed
1XXX 2XXX mm (mils) 0.25 (10) 0.35 (14)
scans/s 400 to 1000 400 to 1000
Reading Distance 100 mm (4 in) - 440 mm (17 in) on 0.50 mm (20 mils) codes 200 mm (8 in) - 600 mm (23.5 in) on 0.50 mm (20 mils) codes
See reading diagrams in par. 3.4 for further details.
3
Page 16
DS2400
1
1.4
ACCESSORIES
The following accessories are available on request for the DS2400: • 90° deflection mirror
GFC-2100
• 20 mA Current Loop interface
INT-22
1.5
GFC-2100 ACCESSORY INSTALLATION
GFC-2100 is a 90° deflection mirror available on request for DS2400. The installation of the 90° deflection mirror is very easy (Figure 1).
CAUTION
Avoid any contact with the deflection mirror, mirrored rotor, the lenses or other optical components, otherwise the performance of the reader will be reduced.
1. Turn off the device. 2. Remove the DS2400 scanning window unscrewing the two cover screws. 3. Fix the mirror to the device by means of the two fixing screws. 4. Remount the scanning window so that the opening face is now at 90° with respect to the DS2400 body. 90° deflection mirror
Cover screws
Scanning window
Fixing screws
Figure 1 - Installation of the deflection mirror
4
Page 17
INSTALLATION
2
2 INSTALLATION 2.1
PACKAGE CONTENTS
Verify that the DS2400 reader and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes: • • • • •
DS2400 reader with cable Installation manual Bar code test chart (PCS = 0.9) DS2400 configuration program disk Mounting kit: - bracket - screws
Figure 2 - DS2400 package contents
5
Page 18
DS2400
2
2.2
MECHANICAL INSTALLATION
DS2400 can be installed to operate in different positions. The four screw holes (M4 x 5) on the body of the reader are for mechanical fixture (Figure A, 8). The diagrams below give the overall dimensions of the scanner and mounting bracket and may be used for installation. Refer to par. 2.5 for correct positioning.
DS2400
B
A mm in MOUNTING BRACKET bottom view
Figure 3 - DS2400 Overall dimensions
6
Page 19
INSTALLATION
2.3
2
JUNCTION BOX INSTALLATION
DS2400
EXT TRIG
PWR/TXD
LASER ON
GOOD READ
The Junction Box provides a passive connection between your scanner and the outside world in a fast and practical way. It represents an alternative to the 25-pin connectors. Figure 4 shows the basic layout of a scanner using the junction box.
Figure 4 - Scanner using Junction Box
For Junction Box connections, the scanner has a cable that terminates in a 24-pin connector that plugs into the junction box. The system cables pass through 6 glands in the side of the Junction Box and the individual wires connect to spring clamp terminal blocks inside which provide access to all scanner signals.
2.3.1
Junction Box Mounting
The diagram below shows the dimensions of the Junction Box and its relative mounting holes.
Figure 5 - Junction Box Overall dimensions
7
Page 20
DS2400
2
The Junction Box is designed to be mounted to a panel of metal, plastic or other appropriate material using the mounting screws provided in the package. To do this: 1) Open the junction box by unscrewing the 4 cover screws. If necessary, using the two mounting holes inside the junction box as a pattern, mark the panel with an appropriate object and then drill two small pilot holes in the panel.
Figure 6 - Mounting Junction Box
2) Align the junction box and insert the two self-threading screws with their washers and screw them into the panel until tight (see Figure 6).
8