Page 41
READING FEATURES
3
3 READING FEATURES The number of scans performed on the code by the DS2400 and therefore the decoding capability is influenced by the following parameters: • • • • number of scans per second code motion speed label dimensions scan direction with respect to code motion
About 5 scans during the code passage should be allowed to ensure a successful read.
3.1
STEP-LADDER MODE
If scanning is perpendicular to the code motion direction (Figure 33), the number of effective scans performed by the reader is given by the following formula: SN = [(LH/LS) * SS] – 2
Where:
SN = number of effective scans LH LS SS
= label height (in mm) = label movement speed in (mm/s) = number of scans per second
Direction of code movement at LS speed LH DS2400
Laser beam
Figure 33 - "Step-Ladder" scanning mode
29
Page 42
DS2400
3
For example, the DS2400 (800 scans/sec.) for a 25 mm high code moving at 1250 mm/s performs: [(25/1250) * 800] - 2 = 14 effective scans.
3.2
PICKET-FENCE MODE
If scanning is parallel to the code motion, (Figure 34), the number of effective scans is given by the following formula: SN = [((FW-LW)/LS) * SS] -2
Where:
SN
= number of effective scans
FW LW LS
= reading field width (in mm) = label width (in mm) = label movement speed (in mm/s) = scans per second
SS
Direction of code movement at LS speed
DS2400
Laser beam LW FW
Figure 34 - "Picket-Fence" scanning mode
For example, for a 100 mm wide code moving in a point where the reading field is 200 mm wide at a 2000 mm/s speed, the DS2400 (800 scans per sec.), performs: [((200-100)/2000) * 800] - 2 = 38 scans
30
Page 43
READING FEATURES
3.3
3
PERFORMANCE
The DS2400 scanner is available in different versions according to the reading performance. Version 1XXX 2XXX
Version 1XXX 2XXX
Max Code Resolution
Speed mm (mils) 0.25 (10) 0.35 (14)
scans/s 400 to 1000 400 to 1000
Reading Distance 100 mm (4 in) - 440 mm (17 in) on 0.50 mm (20 mils) codes 200 mm (8 in) - 600 mm (23.5 in) on 0.50 mm (20 mils) codes
Refer to the diagrams given in par. 3.4 for further details on the reading features. They are taken on various resolution sample codes at a 25 °C ambient temperature, depending on the conditions in the notes under the diagrams.
3.3.1
Raster
Raster versions are available. If standard devices do not satisfy specific requirements, contact your nearest Datalogic distributor, supplying code samples, to obtain complete information on the reading possibilities. The reading characteristics for the raster version is given in the table below. The distance between the top and bottom scan lines is given at different reading distances measured from the laser beam output window. Reading Distance
Raster Capture
300 mm (11.8 in)
600 mm (23.6 in)
18 mm (0.7 in)
35 mm (1.4 in)
31
Page 44
DS2400
3
3.4
READING DIAGRAMS
DS2400-1XXX (Medium Reading Range)
8
20
6
15
4
10
2
5
0
0
2 4 6 8 in
4
8
10
20
12 30
16 40
20 50
24
28 in
60
70 cm
≥0.50 mm (20 mils)
0.25 mm (10 mils)
5 10 15
0.35 mm (14 mils)
20 cm
Note: (0,0) is the center of the laser beam output window.
CONDITIONS Code PCS "Pitch" angle "Skew" angle "Tilt" angle Code Resolution*
= = = = = =
Code Reading Condition* Scanning Speed*
= =
* Parameters selectable in WinHost.
32
Interleaved 2/5 or Code 39 0.90 0° 10° 0° High – for 0.25 mm (10 mils) codes and 0.35 mm, (14 mils) codes Standard – for 0.50 mm (20 mils) codes and greater Standard Speed_3 (800 scans/sec)
Page 45
READING FEATURES
3
DS2400-2XXX (Long Reading Range)
8
20
6
15
4
10
2
5
0
0
2
5
4
10
6
15
8 in
20
4
8
12
16
20
24
28 in
10
20
30
40
50
60
70 cm
0.35 mm (14 mils)
≥ 0.50 mm (20 mils)
cm
Note: (0,0) is the center of the laser beam output window.
CONDITIONS Code PCS "Pitch" angle "Skew" angle "Tilt" angle Code Resolution* Code Reading Condition* Scanning Speed*
= = = = = =
Interleaved 2/5 or Code 39 0.90 0° 10° 0° High - for 0.35 mm (14 mils) codes Standard - for 0.5 mm (20 mils) codes and greater = Standard = Speed_3 (800 scans/sec)
* Parameters selectable in WinHost.
33
Page 46
DS2400
4
4 MAINTENANCE 4.1
CLEANING
Clean the laser beam output window periodically for continued correct operation of the reader. Dust, dirt, etc. on the window may alter the reading performance. Repeat the operation frequently in particularly dirty environments. Use soft material and alcohol to clean the window and avoid any abrasive substances.
Clean the window of the DS2400 when the scanner is turned off or, at least, when the laser beam is deactivated. WARNING
34
Page 47
TECHNICAL FEATURES
5
5 TECHNICAL FEATURES DS2400-1XXX
DS2400-2XXX
ELECTRICAL FEATURES Input Power Supply voltage 10 to 30 Vdc Power consumption max. 5W Serial Interfaces (depends on model) Main RS232; RS485 Full-duplex / Half-duplex; 20 mA C.L. (20 mA C.L. only with INT-22 accessory) Auxiliary RS232 Baud Rates 150 to 115200 Inputs External Trigger Voltage max. Input current max. Outputs OUT1, OUT2 VCE max.
(optocoupled NPN or PNP) 30 Vdc 25 mA (optocoupled) 40 Vdc
Collector current max. VCE saturation
40 mA continuous; 130 mA pulsed 1V at 10 mA max.
Power dissipation max.
90 mW at 40 °C (Ambient temp.)
OPTICAL FEATURES Light source Wave length (Note 1) Safety class
Semiconductor laser diode 630 to 680 nm Class 2 - IEC 825-1; Class II - CDRH
READING FEATURES (Note 2) Scan rate Aperture angle Maximum Reading distance Maximum resolution software programmable (400 to 1000 scans/sec) 50° 440 mm (17.3 inch) 600 mm (23.6 inch) 0.25 mm (10 mils) 0.35 mm (14 mils)
USER INTERFACE LED indicators
Laser ON, Good Read, External Trigger, Data TX / power ON
35
Page 48
DS2400
5 SOFTWARE FEATURES READABLE CODE SYMBOLOGIES • EAN/UPC (including Add-on 2 and Add-on 5) • 2/5 Interleaved • Code 39 (Standard and Full ASCII) • Codabar Other symbologies available on request. Code Selection Decoding Safety Headers and Terminators Operating Modes Configuration Modes
Parameter Storage
• Code 93 • Code 128 • EAN 128 • Pharmacode up to six different codes during one reading phase can enable multiple good reads of same code up to four headers and four terminators On-Line, Automatic, Serial-On-Line, Test • through menus using WinHost utility • receiving commands from one of the serial ports (HOST MODE) Non-volatile internal EEPROM
ENVIRONMENTAL FEATURES Operating temperature (Note 3)
0 to 40 °C (32 to 104 °F)
Storage temperature
-20 to 70 °C (-4 to 158 °F)
Humidity max.
90% non condensing
Vibration resistance
IEC 68-2-6 test FC 1.5 mm; 10 to 55 Hz; 2 hours on each axis
Shock resistance
IEC 68-2-27 test EA 30G; 11 ms; 3 shocks on each axis
Protection class
IP65
PHYSICAL FEATURES Mechanical dimensions
68 x 83.4 x 34 mm (2.7 x 3.28 x 1.3 in)
Weight
330 g. (11.64 oz.)
Note 1:
The features given are typical at a 25 °C ambient temperature (if not otherwise indicated).
Note 2:
Further details given in par. 3.3.
Note 3:
If the reader is used in high temperature environments (over 35 °C), use of the Beam-shutter is advised (see the WinHost configuration program).
36
Page 49
We Datalogic S.p.A. Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy declare under our sole responsibility that the product DS2400-XXXX, Laser Scanner and all its models to which this declaration relates is in conformity with the following standards or other normative documents EN 55022, August 1994:
LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT (ITE)
EN 50082-2, March 1995:
ELECTROMAGNETIC COMPATIBILITY. GENERIC IMMUNITY STANDARD. PART 2: INDUSTRIAL ENVIRONMENT
Following the provision of the Directive(s): 89/336 CEE AND SUCCESSIVE AMENDMENTS, 92/31 CEE; 93/68 CEE
Lippo di Calderara, 09.11.1999
Ruggero Cacioppo Quality Assurance Supervisor