Page 19

INSTALLATION

2 USER INTERFACE

DS2200 3

RXAUX

2

TXAUX

7

SGND

TXD RXD SGND

Figure 7 - RS232 auxiliary interface connections

2.3.4

Inputs

The inputs available on the connector supplied with the scanner are indicated below: Pin

Name

Function

19 22

EXT TRIGI/O REF external trigger (input -) I/O reference

The EXT TRIG input is used to connect the external trigger which tells the scanner to scan for a code. The active state of this input is selected in software. Refer to the WinHost Help On Line. The yellow LED (Figure A, 5) is on when EXT TRIG- is shorted to I/O REF. This input was designed to be driven by an NPN type command. The connections are indicated in the following diagram: EXTERNAL TRIGGER

DS2200 9/13 VS + 5V

V

47K

19

EXT TRIG-

22

I/O REF

Ground

Signal

Figure 8 - External Trigger Input command

This input can be driven by an independently powered source, but the signal on EXT TRIG- must not exceed 9 Vdc. An anti-disturbance hardware filter is implemented on the External Trigger input (< 5 milliseconds delay). An additional 15 ms (typical) delay can be implemented through a dedicated software parameter (refer to WinHost Help On Line).

9

Page 20

DS2200

2

2.3.5

Outputs

Two general purpose outputs are available. These outputs can only be connected as open collector configurations. The following pins are present on the connector of the scanner: Pin

Name

Function

8 11 10, 12, 22

OUT1+ OUT2+ I/O REF output 1 + output 2 + I/O reference

The meaning of the two outputs OUT1 and OUT2 can be defined by the user (No Read, Right or Wrong). Refer to the WinHost Help On Line. By default, OUT1 is associated with the No Read event, which activates when the code signaled by the External Trigger is not decoded, and OUT2 is associated with the Right event, which activates when the code is correctly decoded. DS2200

USER INTERFACE Vext 50 Vdc max, 50 mA max.

8/11

+

10/12/22

I/O REF

Figure 9 - DS2200 output connections

These outputs are both level or pulse configurable.

2.4

POSITIONING

The DS2200 scanner is able to decode barcode labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting the DS2200 take into consideration these three ideal label position angles: Pitch 0°, Skew 15° to 30° and Tilt 0°. Follow the suggestions for the best orientation:

10

Page 21

INSTALLATION

2

The Pitch angle is represented by the value P in Figure 10. Position the reader in order to minimize the Pitch angle. P

Figure 10 - Pitch Angle

The Skew angle is represented by the value S in Figure 11. Position the reader to assure about 15° for the Skew angle. This avoids the direct reflection of the laser light emitted by the DS2200. For the raster version, this angle refers to the most inclined or external raster line, so that all other raster lines assure more than 15° Skew.

S

Figure 11 - Skew angle

The Tilt angle is represented by the value T in Figure 12. Position the reader in order to minimize the Tilt angle. T

Figure 12 - Tilt angle

11

Page 22

DS2200

2

2.5

TYPICAL LAYOUTS

The following typical layouts refer to system hardware configurations. Dotted lines in the figures refer to optional hardware configurations within the particular layout. These layouts also require the correct setup of the software configuration parameters. Complete software configuration procedures can be found in the Guide To Rapid Configuration in the WinHost Help On Line.

2.5.1

Point-to-Point

In this layout data is transmitted to the Host on the RS232 Auxiliary serial interface. The Local Echo communication mode must be enabled (default) see the WinHost Help On Line. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone. Host

EE TT TR RR RIIIG GG G E EX XX XT TT TT

1

TT XD DD AA TA T A T TX XX DA AT TA

PP WE OO ON NN N P PO OO OW W W EE ER RR RO

GG OO OD DR RR EE AA DD G GO OO OO DD RE EA AD D

DS2200

1 Auxiliary serial interface

2

2 External Trigger (for On-Line mode) Figure 13 - Point to Point layout

2.5.2

RS485 Master/Slave

The RS485 Master/Slave connection is used to collect data from several scanners to build a multi-point or a multi-sided reading system; there can be one Master and up to 5 Slaves connected together. The Slave scanners are connected together using the RS485 half-duplex main serial interface. Every Slave scanner must have a multidrop address in the range 0-4.

12

Page 23

INSTALLATION

2

The Master scanner is also connected to the Host on the RS232 auxiliary serial interface. The External Trigger signal is unique to the system; there is a single reading phase and a single message from the Master scanner to the Host computer. It is necessary to bring the External Trigger signal to all the scanners. The main and auxiliary ports are connected as shown in the figure below.

1

2 EE RIIIG E EX XX XT TT TT TT TR RR GG G

TT XD DD AA TT AA A T TX XX DA AT TA

PP W OO ON NN N P PO OO OW W WE EE ER RR RO

GG OOD OD RR EE AA DD D G GO OO OO DR RE EA AD

DS2200 Slave

DS2200 Slave TX TX DATA TX TXDATA DATA DATA EXT EXT TRIG EXT EXTTRIG TRIG TRIG GOOD GOOD READ GOOD GOODREAD READ READ POWER POWER ON POWER POWERON ON ON

PP WE OO NN N P PO OO OW W W EE ER RR RO ON GG OO OD DR RR EE AA DD G GO OO OO DD RE EA AD D EE RIIIG E EX XX XT TT TT TT TR RR GG G TT XD A T TX XX DD DAT AA AT TA AA

1

DS2200 Master

3

1 Auxiliary serial interface 2 RS485 Main serial interface 3 External Trigger

1 Host

Figure 14 – Master/Slave layout

NOTE

The auxiliary serial port of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize data) or to configure it using the WinHost utility or Host Mode programming procedure. The termination resistors of the RS485 bus must not be installed.

13

Page 24

DS2200

2

2.5.3

Multiplexer

Each scanner is connected to a Multiplexer (for example MX4000) with the RS485 half-duplex main interface. 0

GO GG OOO OODDDRRREEEAAADDD PPPO O NN N OOW WW WEEERRROO

3

2

T XXX DDDAAATTTAAA TT EEEXXXTTTTTTRRRIIG II GG

1

31 T XXX DD DAA A TT TAA A TT

3

2

E XX X TT T TT TRR R IIGG GII EE G OO O OO ODD D RR REE E AA A DD D GG PO WEEERRROO O NN N PP OOW WW

PO WEEERRRO PP OOW WW OONNN

T XXX DDDAAATTTAAA TT EEEXXXTTTTTTRRRIIG II GG G GGO OOO OODDDRRREEEAAADDD

2

1

3

Host 1 RS485 Main Interface

MX4000

2 Auxiliary Interface (Local Echo) 3 External Trigger (for On-Line mode)

Figure 15 - Multiplexer layout

The auxiliary serial interface can be used in Local Echo mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode programming procedure. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.

14

Page 25

READING FEATURES

3

3

READING FEATURES

The number of scans performed on the code by the DS2200 and therefore the decoding capability is influenced by the following parameters: • number of scans per second • code motion speed • label dimensions • scan direction with respect to code motion At least 5 scans during the code passage should be allowed to ensure a successful read.

3.1

STEP LADDER MODE Direction of code movement at LS speed LH DS2200

Laser beam

Figure 16 - "Step Ladder" scanning mode

If scanning is perpendicular to the code motion direction (Figure 16), the number of effective scans performed by the reader is given by the following formula: SN = [(LH/LS) * SS] - 2 These symbols signify: SN = number of effective scans LH = label height (in mm) LS = label movement speed (in mm/s) SS = number of scans per second

15

Page 26

DS2200

3

For example, the DS2200 (500 scans/sec.) for a 25 mm high code moving at 500 mm/s performs: [(25/500) * 500] - 2 = 23 effective scans.

3.2

PICKET FENCE MODE Direction of code movement at LS speed DS2200 Laser beam LW FW

Figure 17 - "Picket Fence" scanning mode

If scanning is parallel to the code motion, (Figure 17), the number of effective scans is given by: SN = [((FW-LW)/LS) * SS] -2 These symbols signify: SN FW LW LS SS

= number of effective scans = reading field width (in mm) = label width (in mm) = label movement speed (in mm/s) = scans per second

For example, for a 50 mm wide code moving in a point where the reading field is 100 mm wide at a 1000 mm/s speed, the DS2200 (500 scans per sec.), performs: [((100-50)/1000) * 500] - 2 = 23 scans

16

Page 27

READING FEATURES

3.3

3

PERFORMANCE

The DS2200 scanner is available in different versions according to the reading performance. Version 1XXX 2XXX

Max Code Resolution

Speed mm (mils)

scans/s

0.15 (6) 0.07 (3)

500 500

Version

Reading Distance

1XXX 2XXX

50 mm (2.0 in) - 220 mm (8.7 in) on 0.60 mm (24 mils) codes 40 mm (1.6 in) - 125 mm (4.9 in) on 0.20 mm (8 mils) codes

Refer to the diagrams given in par. 3.4 for further details on the reading features. these diagrams are taken on various resolution sample codes at a 25 °C ambient temperature, depending on the conditions listed under each diagram.

3.3.1

Raster

Raster versions are available. If standard devices do not satisfy specific requirements, contact your nearest Datalogic distributor, supplying code samples, to obtain complete information on the reading possibilities. The max. capture of the Raster version is about 15 mm (0.6 in) at 220 mm (8.7 in).

17