Page 31

INSTALLATION

2.4

2

POSITIONING

The DS2100 scanner is able to decode barcode labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting the DS2100 take into consideration these three ideal label position angles: Pitch 0°, Skew 10° to 30° and Tilt 0°. Follow the suggestions for the best orientation: The Pitch angle is represented by the value P in Figure 19. Position the reader in order to minimize the Pitch angle. P

Figure 19 - Pitch Angle

The Skew angle is represented by the value S in Figure 20. Position the reader to assure at least 10° for the Skew angle. This avoids the direct reflection of the laser light emitted by the DS2100. For the raster version, this angle refers to the most inclined or external raster line, so that all other raster lines assure more than 10° Skew.

S

Figure 20 - Skew angle

19

Page 32

DS2100

2

The Tilt angle is represented by the value T in Figure 21. Position the reader in order to minimize the Tilt angle. T

Figure 21 - Tilt angle

2.5

TYPICAL LAYOUTS

The following typical layouts refer to system hardware configurations. Dotted lines in the figures refer to optional hardware configurations within the particular layout. These layouts also require the correct setup of the software configuration parameters. Complete software configuration procedures can be found in the Guide To Rapid Configuration in the WinHost Help On Line.

20

Page 33

INSTALLATION

2.5.1

2

Point-to-Point

In this layout the data is transmitted to the Host on the main serial interface. Host Mode programming can be accomplished either through the main interface or the Auxiliary interface. In Local Echo communication mode, data is transmitted on the RS232 auxiliary interface independently from the main interface selection. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.

2 1 Terminal

DS2100

Host

3

1 Main serial interface 2 Auxiliary serial interface (Local Echo) 3 External Trigger (for On-Line mode) Figure 22 – Point-to-point layout

This is the only layout available for DS2100-X3XX models.

21

Page 34

DS2100

2

2.5.2

Pass-Through

Pass-through mode allows two or more devices to be connected to a single external serial interface. Each DS2100 transmits the messages received by the Auxiliary interface onto the Main interface. All messages will be passed through this chain to the host. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone. The Main and Auxiliary ports are connected as shown in the following figure: 1 Main serial interface 2 Auxiliary serial interface 3 External Trigger (for On-Line mode) 1

2

DS2100

DS2100

1

Host

3 Figure 23 – Pass-through layout

22

3

Page 35

INSTALLATION

2.5.3

2

RS232 Master/Slave

The RS232 master/slave connection is used to collect data from several scanners to build either a multi-point or a multi-sided reading system; there can be one master and up to 9 slaves connected together. The Slave scanners use RS232 only on the main and auxiliary serial interfaces. Each slave DS2100 transmits the messages received by the auxiliary interface onto the main interface. All messages will be passed through this chain to the Master. The Master scanner is connected to the Host on the main serial interface. The possible main interface types for the master scanner are RS232 or RS485. There is a single reading phase and a single message from the master scanner to the Host computer. Either On-Line or Serial On-Line Operating modes can be used in this layout. When On-Line Operating mode is used, the external trigger signal is unique to the system, however it is not necessary to bring the external trigger signal to the Slave scanners. The main and auxiliary ports are connected as shown in the figure below. 2

1 2

DS2100 Slave

DS2100 Slave DS2100 Master

1

1 3

1 Main serial interface 2 Auxiliary serial interface

Host

3 External Trigger (for On-Line mode) Figure 24 – RS232 Master/slave layout

23

Page 36

DS2100

2

2.5.4

RS485 Master/Slave

The RS485 master/slave connection is used to collect data from several scanners to build a multi-point or a multi-sided reading system; there can be one master and up to 5 slaves connected together. The slave scanners are connected together using RS485 half-duplex on the main serial interface. Every slave scanner must have a multidrop address in the range 0-4. The master scanner is also connected to the Host on the RS232 auxiliary serial interface. The External Trigger signal is unique to the system; there is a single reading phase and a single message from the master scanner to the Host computer. It is necessary to bring the External Trigger signal to all the scanners. The main and auxiliary ports are connected as shown in the figure below. 1 Auxiliary serial interface 2 RS485HD Main serial interface

Host 1

3 External Trigger

2 1

DS2100 Slave

DS2100 Slave DS2100 Master 1

3 Figure 25 – RS485 Master/slave layout

The auxiliary serial interface of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode programming procedure. NOTE

24

The termination resistors of the RS485 bus must not be installed.

Page 37

INSTALLATION

2.5.5

2

Multiplexer Layout

Each scanner is connected to a Multiplexer (for example MX4000) with the RS485 half-duplex main interface. 0 2

2 3

1

1

31 2

3

3

Host 1 Main interface

MX4000

2 Auxiliary interface (Local Echo) 3 External Trigger (for On-Line mode)

Figure 26 - Multiplexer layout

The auxiliary serial interface can be used in Local Echo mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode programming procedure. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.

25

Page 38

DS2100

3

3

READING FEATURES

The number of scans performed on the code by the DS2100 and therefore the decoding capability is influenced by the following parameters: • • • • number of scans per second code motion speed label dimensions scan direction with respect to code motion

At least 5 scans during the code passage should be allowed to ensure a successful read.

3.1

STEP-LADDER MODE

If scanning is perpendicular to the code motion direction (Figure 27), the number of effective scans performed by the reader is given by the following formula: SN = [(LH/LS) * SS] – 2

Where:

SN = number of effective scans LH LS SS

= label height (in mm) = label movement speed in (mm/s) = number of scans per second

Direction of code movement at LS speed LH DS2100

Laser beam

Figure 27 - "Step-Ladder" scanning mode

26

Page 39

READING FEATURES

3

For example, the DS2100 (350 scans/sec.) for a 25 mm high code moving at 500 mm/s performs: [(25/500) * 350] - 2 = 15 effective scans.

3.2

PICKET-FENCE MODE

If scanning is parallel to the code motion, (Figure 28), the number of effective scans is given by the following formula: SN = [((FW-LW)/LS) * SS] -2

Where: SN = number of effective scans FW = reading field width (in mm) LW = label width (in mm) LS = label movement speed (in mm/s) SS = scans per second

Direction of code movement at LS speed

DS2100

Laser beam LW FW

Figure 28 - "Picket-Fence" scanning mode

For example, for a 50 mm wide code moving in a point where the reading field is 200 mm wide at a 1500 mm/s speed, the DS2100 (350 scans per sec.), performs: [((200-50)/1500) * 350] - 2 = 33 scans

27

Page 40

DS2100

3

3.3

PERFORMANCE

The DS2100 scanner is available in different versions according to the reading performance.

Version

Max Code Resolution

Speed

1XX0 1XX4 2XX0 2XX4 mm (mils) 0.20 (8) 0.20 (8) 0.15 (6) 0.12 (5)

scans/s 350 800 350 600

Version

Reading Distance

1XX0 1XX4 2XX0 2XX4

40 mm (1.6 in) - 300 mm (11.8 in) on 0.50 mm (20 mils) codes 45 mm (1.8 in) - 300 mm (11.8 in) on 0.50 mm (20 mils) codes 30 mm (1.2 in) - 90 mm (3.5 in) on 0.30 mm (12 mils) codes 45 mm (1.8 in) - 100 mm (3.9 in) on 0.20 mm (8 mils) codes

Refer to the diagrams given in par. 3.4 for further details on the reading features. They are taken on various resolution sample codes at a 25 °C ambient temperature, depending on the conditions in the notes under the diagrams.

3.3.1

Raster

Raster versions are available. If standard devices do not satisfy specific requirements, contact your nearest Datalogic distributor, supplying code samples, to obtain complete information on the reading possibilities. The max. capture of the Raster version is 18 mm (0.7 in) at 300 mm (11.8 in).

28