Page 11
POWER SUPPLY - This product is intended to be installed by Qualified Personnel only. - Models DS2100-X0XX, DS2100-X1XX: This accessory device is intended to be supplied by a UL Listed Power Unit with «Class 2» or LPS power source which supplies power directly to the scanner via the 25-pin connector. - Model DS2100-X3XX: This accessory device is intended to be supplied by a UL Listed Power Unit with «Class 2» or LPS power source which supplies power directly to the scanner via the 9-pin connector.
ix
Page 12
x
Page 13
GENERAL FEATURES
1
1
GENERAL FEATURES
1.1
INTRODUCTION
The DS2100 laser scanner satisfies the most advanced needs of a wide range of users. It has been developed focusing on the realistic requirements of its target market. The outstanding result is an extremely compact, cost-effective and easy to use industrial scanner. C-Programmability
The DS2100 belongs to the generation of Datalogic scanners that operate under the 'C' programming environment, which is a recognized industry standard.
Standard Application Program
A standard application program is factory-loaded onto the DS2100. This program controls barcode reading, serial port interfacing, data formatting and many other operating and control parameters. It is completely configurable from a host computer through the WinHost utility program provided on diskette with the scanner, or through ESC sequences via the serial interface.
Custom Application Programs
1.2
If the Standard Application Program does not meet your requirements, please contact your local Datalogic distributor.
DESCRIPTION
Some of the main features of DS2100 are listed below: • small dimensions.
• scanning speed up to 800 scans/sec.
• raster version.
• modulated light versions for immunity to ambient light.
•
1 or 2 serial communication interfaces.
• supply voltage from 10 to 30 Vdc.
• reads all popular codes.
1
Page 14
DS2100
1 • test mode to verify the reading features and exact positioning of the scanner without the need for external tools.
• programmable in 4 different operating modes to suit the most various barcode reading system requirements.
• code verifier
• low power consumption.
The DS2100 uses a solid state laser diode as a light source; the light emitted has a wavelength between 630 and 680 nm. Refer to the section “Safety precautions” at the beginning of this manual for information on laser safety. The protection class of the enclosure is IP65, the reader is therefore suitable for industrial environments where high protection against harsh external conditions is required. The four LEDs on the side of the scanner indicate the following: PWR/TXD
LED (red) (Figure A, 5) indicates the reader is connected to the power supply or, when blinking (green), data transmission.
GOOD READ
LED (red) (Figure A, 3) is used to signal the possibility of a successful barcode reading.
EXT TRIG
LED (yellow) (Figure A, 4) indicates external trigger activity. Refer to par. 2.3.4.
LASER ON
LED (green) (Figure A, 2) indicates laser ON state.
The screw holes on the body of the reader are for mechanical fixture (Figure A, 1).
2
Page 15
GENERAL FEATURES
1.3
1
AVAILABLE MODELS
The DS2100 scanner is available in versions that differ in regard to the following parameters: •
Resolution
•
Interface module and termination of the cable
•
Linear or raster models
•
Performance
The following models are therefore available:
DS2100 - X X X X Optical Resolution
Performance
1 = Standard Resolution 2 = High Resolution
0 = Standard 4 = Testarossa™
Serial Communication Interface
Linear/Raster
0 = RS232 main + RS232 aux 25-pin connector 1 = RS485 main + RS232 aux 25-pin connector 3 = RS232 main 9-pin connector
0 = Linear 1 = Raster
The following tables display each version’s reading performance. Version
Max Code Resolution
Speed
1XX0 1XX4 2XX0 2XX4 mm (mils) 0.20 (8) 0.20 (8) 0.15 (6) 0.12 (5)
scans/s 350 800 350 600
Version
Reading Distance
1XX0 1XX4 2XX0 2XX4
40 mm (1.6 in) - 300 mm (11.8 in) on 0.50 mm (20 mils) codes 45 mm (1.8 in) - 300 mm (11.8 in) on 0.50 mm (20 mils) codes 30 mm (1.2 in) - 90 mm (3.5 in) on 0.30 mm (12 mils) codes 45 mm (1.8 in) - 100 mm (3.9 in) on 0.20 mm (8 mils) codes
See reading diagrams in par. 3.4 for further details.
3
Page 16
DS2100
1
1.4
GFC-2100 ACCESSORY INSTALLATION
GFC-2100 is a 90° deflection mirror available on request for DS2100. The installation of the 90° deflection mirror is very easy (Figure 1).
CAUTION
Avoid any contact with the deflection mirror, mirrored rotor, the lenses or other optical components, otherwise the performance of the reader will be reduced.
1. Turn off the device. 2. Remove the DS2100 scanning window unscrewing the two cover screws. 3. Fix the mirror to the device by means of the two fixing screws. 4. Remount the scanning window so that the opening face is now at 90° with respect to the DS2100 body.
90° deflection mirror
Cover screws
Scanning window
Fixing screws
Figure 1 - Installation of the deflection mirror
4
Page 17
INSTALLATION
2
2
INSTALLATION
2.1
PACKAGE CONTENTS
Verify that the DS2100 reader and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes: •
DS2100 reader with cable
•
Installation manual
•
Bar code test chart (PCS = 0.9)
•
DS2100 configuration program disk
•
Mounting kit:
- bracket - screws
Figure 2 - DS2100 package contents
5
Page 18
DS2100
2
2.2
MECHANICAL INSTALLATION
DS2100 can be installed to operate in different positions. The four screw holes (M4 x 5) on the body of the reader are for mechanical fixture (Figure A, 1). The diagrams below give the overall dimensions of the scanner and mounting bracket and may be used for installation. Refer to par. 2.4 for correct positioning. DS2100 84 3.3
14.6 0.57 M 4 n° 4 10.3 0.4
5 0.098
B 34 1.3
68 2.68 46 1.81
40 1.57
10.3 0.4
14.5 0.57
A
40 1.57
23.3 0.92 mm inch
MOUNTING BRACKET 9
1 x 45° n° 2
7.8
4.2
17.5
30
73
40
4.2 n° 2
2.5
4.2
20°
13.8
R
42
90°
23 2.5 mm
Figure 3 - Overall dimensions
6
Page 19
INSTALLATION
2.3
2
ELECTRICAL CONNECTIONS
Several DS2100 models are equipped with a cable terminated by a 25-pin female Dsub connector for connection to the power supply and input/output signals. The details of the connector pins are indicated in the following table.
CAUTION
Do not connect GND and SGND to different (external) ground references. GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
Figure 4 - 25-pin female D-sub connector 25-pin D-sub connector pinout Pin
Name
Function
13 25 1 9
VS GND CHASSIS VS
Power supply input voltage + Power supply input voltage Chassis Ground External Trigger supply voltage +
18 19 8 11 12 22 20 21 23 24 6, 10, 14, 15, 16, 17
EXT TRIG+ EXT TRIGOUT1 + OUT2 + OUT REF OUT REF RXAUX TXAUX CTSAUX RTSAUX NC
External Trigger + External Trigger Output 1 + Output 2 + Output reference Output reference Auxiliary RS232 Auxiliary RS232 Auxiliary handshake RS232 Auxiliary handshake RS232 Not Connected
7
Page 20
DS2100
2
Pin 2 3 4 5 7
RS232 Main interface signals, see par. 2.3.2.
TX232 RX232 RTS232 CTS232 SGND
RS485 full-duplex
RS485 half-duplex
20mA C.L. (INT-22 only)
TX485+ RX485+ TX485RX485SGND
RTX485+
CLOUT+ CLIN+ CLOUTCLIN-
RTX485SGND
Some DS2100 models are equipped with a 9-pin female connector. The details of the connector pins are indicated in the following table:
8
9-pin connector pinout Function
Pin
Name
7 5 8 9 1 2 3 4 6
VS GND EXT TRIG+ EXT TRIGCHASSIS TX232 RX232 CTS232 RTS232
Power supply input voltage + Power supply input voltage External Trigger + External Trigger Chassis Ground TX RS232 Interface RX RS232 Interface CTS RS232 Interface RTS RS232 Interface
1
5
9
6
Figure 5 - 9-pin female connector