Page 19
INSTALLATION
2
For this interface type, the Multidrop Address must also be set via serial channel by the WinHost utility or by ESC sequences. Figure 7 shows an example of a multidrop configuration between a Multiplexer and DS1100 scanners. 120 Ohm max 2 m DS1100 #x (up to 31)
max 1200 m
DS1100 #1 RTX485 +
DS1100 #0
RTX485 SGND
Three wires + shield RTX485 + RTX485 MULTIPLEXER RS485 REF SHIELD
120 Ohm
Figure 7 - DS1100 Multidrop connection to a Multiplexer
9
Page 20
DS1100
2
2.3.3
Auxiliary Interface - RS232
The auxiliary serial interface is used exclusively for RS232 point-to-point connections. It is also used for configuring the DS1100. The parameters relative to the auxiliary interface (baud rate, data bits, etc.) can be defined using the Winhost utility program or "Host Mode Programming", installed from the diskette. The following pins of the 25-pin connector are used to connect the RS232 auxiliary interface: Pin
Name
Function
3, 20 2, 21 7
RXAUX TXAUX SGND received data transmitted data signal ground
DS1100
USER INTERFACE 3/20
RXAUX
2/21
TXAUX
7
SGND
TXD RXD
SGND
Figure 8 - RS232 auxiliary interface connections
10
Page 21
INSTALLATION
2.3.4
2
Inputs
The inputs available on the connector supplied with the scanner are indicated below: Pin
Name
Function
18 19 12, 22
IN1 EXT TRIGGND input 1 external trigger I/O reference
The EXT TRIG input is used to connect the external trigger which tells the scanner to scan for a code. The active state of this input is selected in software. Refer to the Winhost Help On Line. The yellow LED (Figure A, 5) is on when EXT TRIG- is shorted to GND. This input is driven by an NPN type command. The connections are indicated in the following diagram:
DS1100
EXTERNAL TRIGGER
+5V
13/9
VS
19
EXT TRIG -
12/22
GND
V
47 K
Signal Ground
Figure 9 - External Trigger Input command
The general purpose input IN1, in the Standard Application Program, can be used to store the code verifier (see “Store Verifier Hw” in the WinHost Help On Line).
DS1100 +5V
USER INTERFACE 13/9
VS
18
IN1 -
12/22
GND
V
47 K
Ground
Figure 10 - IN1 - Input command
11
Page 22
DS1100
2
An anti-disturbance hardware filter is implemented on the External Trigger input (about 1 millisecond delay). An additional 15 ms (typical) delay can be implemented through a dedicated software parameter (refer to WinHost Help On Line).
2.3.5
Outputs
Two general purpose outputs are available. These outputs can only be connected as open collector configurations. The following pins are present on the 25-pin connector of the scanner: Pin 8 11 12, 22
Name OUT1+ OUT2+ GND
Function output 1 + output 2 + I/O reference
The meaning of the two outputs OUT1 and OUT2 can be defined by the user (No Read, Right or Wrong). Refer to the Winhost Help On Line. By default, OUT1 is associated with the No Read event, which activates when the code signaled by the external trigger is not decoded, and OUT2 is associated with the Right event, which activates when the code is correctly decoded. DS1100
USER INTERFACE Vext 50 Vdc max., 50 mA max.
8/11
+
12/22
GND
Ground
Figure 11 - DS1100 Output connections
These outputs are both level or pulse configurable.
12
Page 23
INSTALLATION
2.4
2
POSITIONING
The DS1100 scanner is able to decode barcode labels at a variety of angles, however significant angular distortion may degrade reading performance. When mounting the DS1100 take into consideration these three ideal label position angles: Pitch 0°, Skew 15° to 30° and Tilt 0°. Follow the suggestions for the best orientation: The Pitch angle is represented by the value P in Figure 12. Position the reader in order to minimize the Pitch angle. P
Figure 12 - Pitch Angle
The Skew angle is represented by the value S in Figure 13. Position the reader to assure about 15° for the Skew angle. This avoids the direct reflection of the laser light emitted by the DS1100. For the raster version, this angle refers to the most inclined or external raster line, so that all other raster lines assure more than 15° Skew. For the skew angle value with DS1100 90° versions, refer to par. 2.2.1.
S
Figure 13 - Skew angle
13
Page 24
DS1100
2
The Tilt angle is represented by the value T in Figure 14. Position the reader in order to minimize the Tilt angle. T
Figure 14 - Tilt angle
2.5
TYPICAL LAYOUTS
The following typical layouts refer to system hardware configurations. Dotted lines in the figures refer to optional hardware configurations within the particular layout. These layouts also require the correct setup of the software configuration parameters. Complete software configuration procedures can be found in the Guide To Rapid Configuration in the WinHost Help On Line.
14
Page 25
INSTALLATION
2.5.1
2
Point-to-Point
In this layout data is transmitted to the Host on the RS232 Auxiliary serial interface. The Local Echo communication mode must be enabled (default) See the Winhost Help On Line. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.
Host 1
DS1100
2
1
Auxiliary Serial Interface
2
External Trigger (for On-Line mode)
Figure 15 – Point to Point Layout
2.5.2
RS485 Master/Slave
The RS485 master/slave connection is used to collect data from several scanners to build a multi-point or a multi-sided reading system; there can be one master and up to 5 slaves connected together. The Slave scanners are connected together using the RS485 half-duplex main serial interface. Every slave scanner must have a multidrop address in the range 0-4. The master scanner is also connected to the Host on the RS232 auxiliary serial interface. The External Trigger signal is unique to the system; there is a single reading phase and a single message from the master scanner to the Host computer. It is necessary to bring the External Trigger signal to all the scanners. The main and auxiliary ports are connected as shown in the following figure.
15
Page 26
DS1100
2
Slave
2
1 DS1100
1
DS1100
Slave
DS1100
3
1 1
Auxiliary serial interface
2
RS485 Main serial interface
3
External Trigger
Master
Host
Figure 16 – RS485 Master/slave layout
NOTE
16
The auxiliary serial port of the slave scanners can be used in Local Echo communication mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode programming procedure. The termination resistors of the RS485 bus must not be installed.
Page 27
INSTALLATION
2.5.3
2
Multiplexer
Each scanner is connected to a Multiplexer (for example MX4000) with the RS485 half-duplex main interface. 1
31
1
0
MX4000 2
Host
DS1100
3
2
DS1100
2
3
DS1100
3
1
Main interface
2
Auxiliary Interface (Local Echo)
3
External Trigger (for On-Line mode)
Figure 17 - Multiplexer layout
The auxiliary serial interface can be used in Local Echo mode to control any single scanner (visualize collected data) or to configure it using the WinHost utility or Host Mode programming procedure. When On-Line Operating mode is used, the scanner is activated by an External Trigger (photoelectric sensor) when the object enters its reading zone.
17