Page 10
POWER SUPPLY This device is intended to be supplied by a UL Listed Power Unit with "Class 2" or LPS power source which supplies power directly to the scanner via the 25-pin connector.
viii
Page 11
GENERAL FEATURES
1
GENERAL FEATURES
1.1
INTRODUCTION
1
The DS1100 scanner with decoder offers the best cost-effective solution for demanding industrial applications. The DS1100 ultra compact dimensions, based on Datalogic experience in miniaturized laser components, have been specifically designed to make the scanner's integration into automated equipment extremely easy. The Windows-based user-friendly WinHost utility program provided on diskette simplifies the scanner’s setup. The DS1100 can also be configured from a Host PC through the Host Mode procedure.
1.2
DESCRIPTION
Some of the main features of DS1100 are listed below: • miniaturized dimensions, light weight;
• scanning speed: 350 scans/sec;
• raster version available;
•
2 serial communication interfaces: RS232 + RS485;
• reads all popular codes;
• supply voltage: 5 Vdc ( 4 to 30 Vdc with converter);
• test mode to verify the reading features and exact positioning of the scanner without the need for external tools;
• programmable in 4 different operating modes to suit the most various barcode reading system requirements;
• code verifier;
• programmable input and output signals;
• light source: visible laser diode; the light emitted has a wave length of 630 ∼ 680 nm. For laser safety precautions refer to the “Safety Precautions” section at the beginning of this manual;
• low power consumption;
•
IP65 protection class of the enclosure; the reader is therefore suitable for industrial environments where high protection against harsh external conditions is required;
1
Page 12
DS1100
1
The laser beam output window is on the side of the scanner in DS1100-XXX0 models and on the upper part of the scanner in DS1100-XXX1 models, (Figure A, 1). A security system allows the laser to activate only once the motor has reached the correct rotational speed; consequently, the laser beam is generated after a slight delay from the power on of the scanner.
1.2.1
Indicators
The five LEDs on the scanner indicate the following: POWER ON EXT TRIG LASER ON GOOD READ TX DATA
(red) indicates the reader is connected to the power supply. (Figure A, 6). (yellow) indicates external trigger activity. Refer to par. 2.3.4. (Figure A, 5). (green) indicates laser ON state. (Figure A, 4). (red) is used to signal the possibility of a successful barcode reading. (Figure A, 3). (green). When blinking, it indicates data transmission. (Figure A, 2).
The screw holes on the body of the reader are for mechanical fixture (Figure A, 8).
1.3
AVAILABLE MODELS
The DS1100 scanner is available in versions that differ in regard to the following parameters: •
Resolution.
•
Reading window position.
•
Linear or raster models.
2
Page 13
GENERAL FEATURES
1
The following models are therefore available:
DS1100 - X X X X Optical Resolution
Reading Window Position
1 = Standard Resolution 2 = High Resolution
0 = Direct 1 = 90°
Serial Interface
Linear/Raster
1 = RS232 + RS485
0 = Linear 1 = Raster
The following tables display each version’s reading performance. Version 1XXX 2XXX
Max Code Resolution
Speed mm (mils)
scans/s
0.20 (8) 0.12 (5)
350
350
Version
Reading Distance
1XXX 2XXX
30 mm (1.2 in) - 220 mm (8.7 in) on 0.50 mm (20 mils) codes 10 mm (0.4 in) - 110 mm (4.3 in) on 0.30 mm (12 mils) codes
See reading diagrams in par. 3.4 for further details.
1.4
ACCESSORIES
The following accessory is available on request: DC5-2200: DC converter 4-30 Vdc to 5 Vdc.
3
Page 14
DS1100
2
2
INSTALLATION
2.1
PACKAGE CONTENTS
Verify that the DS1100 reader and all the parts supplied with the equipment are present and intact when opening the packaging; the list of parts includes: •
DS1100 reader with cable
•
Installation Manual
•
DS1100 configuration program disk
•
Bar code test chart (PCS = 0.9)
•
Mounting kit:
- bracket - screws
Figure 1 - DS1100 package contents
4
Page 15
INSTALLATION
2.2
2
MECHANICAL INSTALLATION
DS1100 can be installed to operate in any position. There are three screw holes (M3 x 5) on the body of the reader for mounting. The diagram below gives all the information required for installation; refer to par. 2.4 for correct positioning of the scanner with respect to the code passage zone. DS1100
4 0.16
6 0.24
50 1.97
A
15.4 0.61
B
61 2.4
4 0.16 64.3 2.53
80 3.15
M3 n°3
22.5 0.89
7.7 0.3 mm inch
MOUNTING BRACKET
Figure 2 - DS1100 overall dimensions
5
Page 16
DS1100
2
2.2.1
Reading Position
In DS1100-XXX1 models the laser beam is emitted from the output window with a 12° (± 2) skew angle. This allows installation with minimum overall dimensions.
DS1100-XXX1 90° Reading Window Position
12° ± 2 Laser Beam
Laser Beam
DS1100-XXX0 Direct Reading Window Position
Figure 3 - Reading position
6
± 2°
Page 17
INSTALLATION
2.3
2
ELECTRICAL CONNECTIONS
The DS1100 cable is equipped with a 25-pin female D-sub connector for connection with the power supply and input/output signals:
CAUTION
Do not connect GND and SGND to different (external) ground references. GND and SGND are internally connected through filtering circuitry which can be permanently damaged if subjected to voltage drops over 0.8 Vdc.
Figure 4 – 25-pin female D-sub connector 25-pin D-sub connector pinout Pin 9,13 25 1* 2, 21 3, 20 4 5 7 8 11 18 19 12, 22 23, 24 6, 10, 14, 15, 16, 17
Name VS GND CHASSIS TXAUX RXAUX RTX485RTX485+ SGND OUT1 + OUT2 + IN1 EXT TRIGGND N.U. NC
Function Power supply input voltage + Power supply input voltage Chassis Ground TX RS232 Aux. Interface RX RS232 Aux. Interface RTX- RS485 Main Interface RTX+ RS485 Main Interface Signal Ground Output 1 + Output 2 + Input 1 External trigger Input/Output reference Not Used Not Connected
* Pins 1 and 25 are connected together internally.
7
Page 18
DS1100
2
2.3.1
Power Supply
The following pins of the DS1100 connector are used: DS1100
USER INTERFACE 13/9 V+ (5 Vdc)
VS 25
GND
GND 1
CHASSIS
Figure 5 - Power supply connections
The power must be 5 Vdc only.
2.3.2
Main Serial Interface - RS485 Half-Duplex
The RS485 half-duplex interface (3 wires + shield) is used for polled communication protocols. It can be used for Multidrop connections in a master/slave layout or with a Datalogic Multiplexer, (see par. 2.5.2 and 2.5.3) exploiting a proprietary protocol based on polled mode called MUX32 protocol, where a master device polls slave devices to collect data. The connector pinout follows: Pin
Name
Function
5 4 7
RTX485+ RTX485 SGND
RS485 transmitted/received data + RS485 transmitted/received data signal ground
DS1100
USER INTERFACE 5
RTX485 +
4
RTX485 -
7
SGND
RTX485 + RTX485 -
RS485 Ref
Figure 6 - RS485 half-duplex connections
8