Page 28
DS1100
3
3
READING FEATURES
The number of scans performed on the code by the DS1100 and therefore the decoding capability is influenced by the following parameters: • number of scans per second • code motion speed • label dimensions • scan direction with respect to code motion Typically, 5 scans should be allowed during the code passage to ensure a successful read.
3.1
STEP-LADDER MODE Direction of code movement at LS speed DS1100
LH
Laser beam
Figure 18 - "Step-ladder" scanning mode
If scanning is perpendicular to the code motion direction (Figure 18), the number of effective scans performed by the reader is given by the following formula: SN = [(LH/LS) * SS] - 2 These symbols signify: SN = number of effective scans LH = label height (in mm) LS = label movement speed (in mm/s) SS = number of scans per second
18
Page 29
READING FEATURES
3
For example, the DS1100 (350 scans/sec.) for a 25 mm high code moving at 500 mm/s performs: [(25/500) * 350] - 2 = 15 effective scans.
3.2
PICKET-FENCE MODE Direction of code movement at LS speed
Laser beam DS1100 LW FW
Figure 19 - "Picket-fence" scanning mode
If scanning is parallel to the code motion, (Figure 19), the number of effective scans is given by: SN = [((FW-LW)/LS) * SS] -2 These symbols signify: SN = number of effective scans FW = reading field width (in mm) LW = label width (in mm) LS = label movement speed (in mm/s) SS = scans per second For example, for a 50 mm wide code moving in a point where the reading field is 180 mm wide at a 1300 mm/s speed, the DS1100 (350 scans per sec.), performs: [((180-50)/1300) * 350] - 2 = 33 scans
19
Page 30
DS1100
3
3.3
PERFORMANCE
The DS1100 scanner is available in different versions according to the reading performance. Version 1XXX 2XXX
Max Code Resolution
Speed mm (mils)
scans/s
0.20 (8) 0.12 (5)
350 350
Version
Reading Distance
1XXX 2XXX
30 mm (1.2 in) - 220 mm (8.7 in) on 0.50 mm (20 mils) codes 10 mm (0.4 in) - 110 mm (4.3 in) on 0.30 mm (12 mils) codes
Refer to the diagrams given in par. 3.4 for further details on the reading features. These diagrams are taken on various resolution sample codes at a 25°C ambient temperature, depending on the conditions listed under each diagram.
3.3.1
Raster
Raster versions are available. If standard devices do not satisfy specific requirements, contact your nearest Datalogic distributor, supplying code samples, to obtain complete information on the reading possibilities. The max. capture of raster versions is 15 mm (0.6 in) at 220 mm (8.7 in).
20
Page 31
READING FEATURES
3.4
3
READING DIAGRAMS
The following diagrams show the reading distance for barcodes with different densities.
DS1100-1XXX Standard Resolution 0
1
0 5 4 3
20
2 40
3 60
4
5
6
7
8
9
10
(in)
80 100 120 140 160 180 200 220 240 260 (mm)
120 100 80 60
2 40 1
20
0
0
1
20
2
0.20 mm (8 mils)
0.30 mm (12 mils)
≥ 0.50 mm (20 mils)
40 60
3
80
4
100
5
120 (mm)
(in) Note: (0,0) is the center of the laser beam output window.
CONDITIONS: Code PCS "Pitch" angle "Skew" angle "Tilt" angle
= = = = =
Interleaved 2/5 or Code 39 0.90 0° 15° 0°
21
Page 32
DS1100
3
DS1100-2XXX High Resolution 0
1
0
10
20
2 30
40
50
3 60
70
4 80
5
90 100 110 120 130
60 2
50 40 30
1 20 10 0
0.12 mm (5 mils)
0 10 20
1 30 40 2
50
60 (in) (mm)
Note: (0,0) is the center of the laser beam output window.
CONDITIONS: Code PCS "Pitch" angle "Skew" angle Tilt" angle
22
= = = = =
Interleaved 2/5 or Code 39 0.90 0° 15° 0°
0.20 mm (8 mils)
≥ 0.30 mm (12 mils)
(in) (mm)
Page 33
MAINTENANCE
4
4
MAINTENANCE
4.1
CLEANING
Clean the windows periodically for continued correct operation of the reader. Dust, dirt, etc. on the windows may alter the reading performance. Repeat the operation frequently in particularly dirty environments. Use soft material and alcohol to clean the windows and avoid any abrasive substances.
Clean the window of the DS1100 when the scanner is turned off or, at least, when the laser beam is deactivated. WARNING
23
Page 34
DS1100
5
5
TECHNICAL FEATURES DS1100-1XXX
DS1100-2XXX
ELECTRICAL FEATURES Power Maximum input voltage Power consumption max.
5 Vdc ± 5% 1.5 W
Serial Interfaces Main Auxiliary Baud Rates Inputs Outputs VCE max. Collector current max. VCE saturation Power dissipation max.
RS485 half-duplex RS232 150 to 115200 baud External Trigger; IN1 User-defined OUT1 and OUT2 50 Vdc 50 mA continuous 0.3V at 10 mA max. 200 mW at 40 °C (Ambient temp.)
OPTICAL FEATURES Light source Wave length (Note 1) Safety class
Semiconductor laser diode 630 ∼ 680 nm Class 2 - IEC 825-1; Class II - CDRH
READING FEATURES (Note 2) Scan rate Aperture angle Max. Reading distance Maximum resolution
350 scans/sec 70° 220 mm, (8.7 in) 110 mm (4.3 in) 0.20 mm (8 mils) 0.12 mm (5 mils)
USER INTERFACE LED indicators
24
Power On, Good Read, Ext Trig, TX Data, Laser On
Page 35
TECHNICAL FEATURES
5
SOFTWARE FEATURES READABLE CODE SYMBOLOGIES • EAN/UPC (including Add-on 2 and Add-on 5) • Code 93 • 2/5 Interleaved • Code 128 • Code 39 (Standard and Full ASCII) • EAN 128 • Codabar • Pharmacode Other symbologies available on request. CODE SELECTION up to six different codes during one reading phase DECODING SAFETY can enable multiple good reads of same code HEADERS AND TERMINATORS up to four headers and four terminators OPERATING MODES On-Line, Automatic, Serial-On-Line, Test CONFIGURATION MODES • through menus using WinHost utility • receiving commands from one of the serial ports (HOST MODE) PARAMETER STORAGE Non-volatile internal EEPROM
ENVIRONMENTAL FEATURES Operating temperature (Note 3)
0° to 45 °C (32° to 113 °F)
Storage temperature
-20° to 70 °C (-4° to 158 °F) 90% non condensing IEC 68-2-6 test FC 1.5 mm; 10 to 55 Hz; 2 hours on each axis IEC 68-2-27 test EA 30G; 11 ms; 3 shocks on each axis IP65
Humidity max. Vibration resistance Shock resistance Protection class
PHYSICAL FEATURES Mechanical dimensions Weight without cable
80 x 50 x 22 mm (3.15 x 1.97 x 0.89 in.) <100 g. (<3.53 oz.)
Note 1:
The features given are typical at a 25 °C ambient temperature (if not otherwise indicated).
Note 2:
Further details given in par. 3.3 and 3.4.
Note 3:
If the reader is used for a long period of time in high temperature environments (over 40 °C), use of the Beam Shutter is advised (see the Winhost configuration program).
25
Page 36
We
Datalogic S.p.A. Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy declare under our sole responsibility that the product(s) DS1100-XXXX, Laser Scanner and all its models to which this declaration relates is in conformity with the following standard(s) or other normative document(s) EN 55022, August 1994:
LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT (ITE)
EN 50082-2, March 1995:
ELECTROMAGNETIC COMPATIBILITY. GENERIC IMMUNITY STANDARD. PART 2: INDUSTRIAL ENVIRONMENT
Following the provision of the Directive(s): 89/336 CEE AND SUCCESSIVE AMENDMENTS, 92/31 CEE; 93/68 CEE
Lippo di Calderara, 12/07/1999
Ruggero Cacioppo
Quality Assurance Supervisor