Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 4

DS1100 Installation Manual, pages 28 to 36

Pages 28 to 36 of 36

The original document is the PDF (3.0 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic DS-1100

Page 28

DS1100

3

3

READING FEATURES

The number of scans performed on the code by the DS1100 and therefore the decoding capability is influenced by the following parameters: • number of scans per second • code motion speed • label dimensions • scan direction with respect to code motion Typically, 5 scans should be allowed during the code passage to ensure a successful read.

3.1

STEP-LADDER MODE Direction of code movement at LS speed DS1100

LH

Laser beam

Figure 18 - "Step-ladder" scanning mode

If scanning is perpendicular to the code motion direction (Figure 18), the number of effective scans performed by the reader is given by the following formula: SN = [(LH/LS) * SS] - 2 These symbols signify: SN = number of effective scans LH = label height (in mm) LS = label movement speed (in mm/s) SS = number of scans per second

18

Page 29

READING FEATURES

3

For example, the DS1100 (350 scans/sec.) for a 25 mm high code moving at 500 mm/s performs: [(25/500) * 350] - 2 = 15 effective scans.

3.2

PICKET-FENCE MODE Direction of code movement at LS speed

Laser beam DS1100 LW FW

Figure 19 - "Picket-fence" scanning mode

If scanning is parallel to the code motion, (Figure 19), the number of effective scans is given by: SN = [((FW-LW)/LS) * SS] -2 These symbols signify: SN = number of effective scans FW = reading field width (in mm) LW = label width (in mm) LS = label movement speed (in mm/s) SS = scans per second For example, for a 50 mm wide code moving in a point where the reading field is 180 mm wide at a 1300 mm/s speed, the DS1100 (350 scans per sec.), performs: [((180-50)/1300) * 350] - 2 = 33 scans

19

Page 30

DS1100

3

3.3

PERFORMANCE

The DS1100 scanner is available in different versions according to the reading performance. Version 1XXX 2XXX

Max Code Resolution

Speed mm (mils)

scans/s

0.20 (8) 0.12 (5)

350 350

Version

Reading Distance

1XXX 2XXX

30 mm (1.2 in) - 220 mm (8.7 in) on 0.50 mm (20 mils) codes 10 mm (0.4 in) - 110 mm (4.3 in) on 0.30 mm (12 mils) codes

Refer to the diagrams given in par. 3.4 for further details on the reading features. These diagrams are taken on various resolution sample codes at a 25°C ambient temperature, depending on the conditions listed under each diagram.

3.3.1

Raster

Raster versions are available. If standard devices do not satisfy specific requirements, contact your nearest Datalogic distributor, supplying code samples, to obtain complete information on the reading possibilities. The max. capture of raster versions is 15 mm (0.6 in) at 220 mm (8.7 in).

20

Page 31

READING FEATURES

3.4

3

READING DIAGRAMS

The following diagrams show the reading distance for barcodes with different densities.

DS1100-1XXX Standard Resolution 0

1

0 5 4 3

20

2 40

3 60

4

5

6

7

8

9

10

(in)

80 100 120 140 160 180 200 220 240 260 (mm)

120 100 80 60

2 40 1

20

0

0

1

20

2

0.20 mm (8 mils)

0.30 mm (12 mils)

≥ 0.50 mm (20 mils)

40 60

3

80

4

100

5

120 (mm)

(in) Note: (0,0) is the center of the laser beam output window.

CONDITIONS: Code PCS "Pitch" angle "Skew" angle "Tilt" angle

= = = = =

Interleaved 2/5 or Code 39 0.90 0° 15° 0°

21

Page 32

DS1100

3

DS1100-2XXX High Resolution 0

1

0

10

20

2 30

40

50

3 60

70

4 80

5

90 100 110 120 130

60 2

50 40 30

1 20 10 0

0.12 mm (5 mils)

0 10 20

1 30 40 2

50

60 (in) (mm)

Note: (0,0) is the center of the laser beam output window.

CONDITIONS: Code PCS "Pitch" angle "Skew" angle Tilt" angle

22

= = = = =

Interleaved 2/5 or Code 39 0.90 0° 15° 0°

0.20 mm (8 mils)

≥ 0.30 mm (12 mils)

(in) (mm)

Page 33

MAINTENANCE

4

4

MAINTENANCE

4.1

CLEANING

Clean the windows periodically for continued correct operation of the reader. Dust, dirt, etc. on the windows may alter the reading performance. Repeat the operation frequently in particularly dirty environments. Use soft material and alcohol to clean the windows and avoid any abrasive substances.

Clean the window of the DS1100 when the scanner is turned off or, at least, when the laser beam is deactivated. WARNING

23

Page 34

DS1100

5

5

TECHNICAL FEATURES DS1100-1XXX

DS1100-2XXX

ELECTRICAL FEATURES Power Maximum input voltage Power consumption max.

5 Vdc ± 5% 1.5 W

Serial Interfaces Main Auxiliary Baud Rates Inputs Outputs VCE max. Collector current max. VCE saturation Power dissipation max.

RS485 half-duplex RS232 150 to 115200 baud External Trigger; IN1 User-defined OUT1 and OUT2 50 Vdc 50 mA continuous 0.3V at 10 mA max. 200 mW at 40 °C (Ambient temp.)

OPTICAL FEATURES Light source Wave length (Note 1) Safety class

Semiconductor laser diode 630 ∼ 680 nm Class 2 - IEC 825-1; Class II - CDRH

READING FEATURES (Note 2) Scan rate Aperture angle Max. Reading distance Maximum resolution

350 scans/sec 70° 220 mm, (8.7 in) 110 mm (4.3 in) 0.20 mm (8 mils) 0.12 mm (5 mils)

USER INTERFACE LED indicators

24

Power On, Good Read, Ext Trig, TX Data, Laser On

Page 35

TECHNICAL FEATURES

5

SOFTWARE FEATURES READABLE CODE SYMBOLOGIES • EAN/UPC (including Add-on 2 and Add-on 5) • Code 93 • 2/5 Interleaved • Code 128 • Code 39 (Standard and Full ASCII) • EAN 128 • Codabar • Pharmacode Other symbologies available on request. CODE SELECTION up to six different codes during one reading phase DECODING SAFETY can enable multiple good reads of same code HEADERS AND TERMINATORS up to four headers and four terminators OPERATING MODES On-Line, Automatic, Serial-On-Line, Test CONFIGURATION MODES • through menus using WinHost utility • receiving commands from one of the serial ports (HOST MODE) PARAMETER STORAGE Non-volatile internal EEPROM

ENVIRONMENTAL FEATURES Operating temperature (Note 3)

0° to 45 °C (32° to 113 °F)

Storage temperature

-20° to 70 °C (-4° to 158 °F) 90% non condensing IEC 68-2-6 test FC 1.5 mm; 10 to 55 Hz; 2 hours on each axis IEC 68-2-27 test EA 30G; 11 ms; 3 shocks on each axis IP65

Humidity max. Vibration resistance Shock resistance Protection class

PHYSICAL FEATURES Mechanical dimensions Weight without cable

80 x 50 x 22 mm (3.15 x 1.97 x 0.89 in.) <100 g. (<3.53 oz.)

Note 1:

The features given are typical at a 25 °C ambient temperature (if not otherwise indicated).

Note 2:

Further details given in par. 3.3 and 3.4.

Note 3:

If the reader is used for a long period of time in high temperature environments (over 40 °C), use of the Beam Shutter is advised (see the Winhost configuration program).

25

Page 36

We

Datalogic S.p.A. Via Candini, 2 40012 - Lippo di Calderara Bologna - Italy declare under our sole responsibility that the product(s) DS1100-XXXX, Laser Scanner and all its models to which this declaration relates is in conformity with the following standard(s) or other normative document(s) EN 55022, August 1994:

LIMITS AND METHODS OF MEASUREMENTS OF RADIO DISTURBANCE CHARACTERISTICS OF INFORMATION TECHNOLOGY EQUIPMENT (ITE)

EN 50082-2, March 1995:

ELECTROMAGNETIC COMPATIBILITY. GENERIC IMMUNITY STANDARD. PART 2: INDUSTRIAL ENVIRONMENT

Following the provision of the Directive(s): 89/336 CEE AND SUCCESSIVE AMENDMENTS, 92/31 CEE; 93/68 CEE

Lippo di Calderara, 12/07/1999

Ruggero Cacioppo

Quality Assurance Supervisor