The text of a manual · part 3 of 5
DL910 Series Instruction Manual, pages 19 to 27
Pages 19 to 27 of 42
The original document is the PDF (503 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Datalogic DL910
Page 19
DATALOGIC
DL910 SERIES
2/5 CODE FAMILY INTERLEAVED 2/5
Disables the family
GcCgCmCcCjGjCjCjGcCgJcGgGcCjJcGjJcCcG AC0
1. Enable the code by selecting one of the check digit selections.
no check digit control (*)
GcCgCmCcCjGjCjCjGcCgJgGcCgJgGcCgJgGcGjJcCcG AC11 check digit control and transmission
GcCgCmCcCjGjCjCjGcCgJgGcGgJgCcGcJgCgGjJcCcG AC12 control without check digit transmission
GcCgCmCcCjGjCjCjGcCgJgGcGgCcJgJgCcGgGjJcCcG AC13
2. Read two numbers between 00 and 99 from the table in par. 2.7 to select the code length starting from the most significant digit. Number 00 indicates variable code length. Number 99 indicates same code length as the first code read. (*) Default
Configuration - 2.9
Page 20
DL910 SERIES
DATALOGIC
2/5 CODE FAMILY NORMAL 2/5 CODE (5 BARS)
Disables the family
GcCgCmCcCjGjCjCjGcCgJcGgGcCjJcGjJcCcG AC0
1. Enable the code by selecting one of the check digit selections.
no check digit control (*)
GcCgCmCcCjGjCjCjGcGgJgCcCgJgGcGgCgJcGjJcCcG AC21 check digit control and transmission
GcCgCmCcCjGjCjCjGcGgJgCcGgJgCcJcCgGgGjJcCcG AC22 check digit control without transmission
GcCgCmCcCjGjCjCjGcGgJgCcGgCcJgJgGcCgGjJcCcG AC23
2. Read two numbers between 00 and 99 from the table in par. 2.7 to select the code length starting from the most significant digit. Number 00 indicates variable code length. Number 99 indicates same code length as the first code read.
(*) Default
2.10 - Configuration
Page 21
DATALOGIC
DL910 SERIES
CODE 2/5 FAMILY INDUSTRIAL 2/5 (IATA)
Disables the family
GcCgCmCcCjGjCjCjGcCgJcGgGcCjJcGjJcCcG AC0
1. Enable the code by selecting one of the check digit selections.
no check digit control
GcCgCmCcCjGjCjCjGcGgCcJgCgJgGcJcGcJcGjJcCcG AC31 check digit control and transmission
GcCgCmCcCjGjCjCjGcGgCcJgGgJgCcJcGgCgGjJcCcG AC32 check digit control without transmission
GcCgCmCcCjGjCjCjGcGgCcJgGgCcJgGcGjGcGjJcCcG AC33
2. Read two numbers between 00 and 99 from the table in par. 2.7 to select the code length starting from the most significant digit. Number 00 indicates variable code length. Number 99 indicates same code length as the first code read.
Configuration - 2.11
Page 22
DL910 SERIES
DATALOGIC
2/5 CODE FAMILY MATRIX 2/5 (3 BARS)
Disables the family
GcCgCmCcCjGjCjCjGcCgJcGgGcCjJcGjJcCcG AC0
1. Enable the code by selecting one of the check digit selections.
no check digit control
GcCgCmCcCjGjCjCjGcGgCgJcCgJgGcJgCgGcGjJcCcG AC41 check digit control and transmission
GcCgCmCcCjGjCjCjGcGgCgJcGgJgCcGcGcGjGjJcCcG AC42 check digit control without transmission
GcCgCmCcCjGjCjCjGcGgCgJcGgCcJgCjCcGjGjJcCcG AC43
2. Read two numbers between 00 and 99 from the table in par. 2.7 to select the code length starting from the most significant digit. Number 00 indicates variable code length. Number 99 indicates same code length as the first code read.
2.12 - Configuration
Page 23
DATALOGIC
DL910 SERIES
CODABAR FAMILY Disables the family
GcCgCmCcCjGjCcGjCjCgJcGgGcJcCjGjJcCcG AD0
STANDARD CODABAR 1. Enable the code by selecting one of the start/stop character control selections. no start/stop character equality control (*)
GcCgCmCcCjGjCcGjCjCgJgGcCgJgGcGgCcJgGjJcCcG AD11 with start/stop character equality control
GcCgCmCcCjGjCcGjCjCgJgGcGgJgCcJcGcJcGjJcCcG AD12
2. Read a code from the start/stop character transmission table below: ABC CODABAR 1. Enable the code by selecting one of the start/stop character control selections. no start/stop character equality control
GcCgCmCcCjGjCcGjCjGgJgCcCgJgGcGgJcCgGjJcCcG AD21 with start/stop character equality control
GcCgCmCcCjGjCcGjCjGgJgCcGgJgCcJgCgGcGjJcCcG AD22
2. Read a code from the start/stop character transmission table below: START/STOP CHARACTER TRANSMISSION not transmitted
GcCgCmCgJgGcGgJgCcGjJcCcG 1 transmitted unchanged (*)
GcCgCmGgJgCcGgCcJgGjJcCcG 2 transmitted as DC1 DC2 DC3 DC4
GcCgCmGgCcJgGgCgJcGjJcCcG 3
(*) Default Configuration - 2.13
Page 24
DL910 SERIES
DATALOGIC
MSI Disables the code
GcCgCmCcCjGjCjGcCjCgJcGgGcJcJcGjJcCcG AE0
1. Enable the code by selecting one of the check digit selections.
no check digit control
GcCgCmCcCjGjCjGcCjCgJgGcJjCcGcGjJcCcG AE1 control and transmission of 1 check digit
GcCgCmCcCjGjCjGcCjGgJgCcJjGcCcGjJcCcG AE2 control without transmission of 1 check digit
GcCgCmCcCjGjCjGcCjGgCcJgMjCcCcGjJcCcG AE3
MOD.10 - two check digit control with transmission of the first
GcCgCmCcCjGjCjGcCjGgCgJcCgCcGmGjJcCcG AE4
MOD.10 - two check digit control with transmission of both
GcCgCmCcCjGjCjGcCjGcJgCgCmCgGcGjJcCcG AE5
MOD.10 - two check digit control without transmission
GcCgCmCcCjGjCjGcCjGgJcCgCgGcCmGjJcCcG AE6
2.14 - Configuration
Page 25
DATALOGIC
MOD.11 - MOD.10 two check digit control with transmission of the first
DL910 SERIES
GcCgCmCcCjGjCjGcCjJcGcJcCmGgCcGjJcCcG AE7
MOD.11 - MOD.10 two check digit control with transmission of both
GcCgCmCcCjGjCjGcCjJcCgGgMcJcCcGjJcCcG AE8
MOD.11 - MOD.10 two check digit control without transmission
GcCgCmCcCjGjCjGcCjJgCcGgCcCgMgGjJcCcG AE9
2. Read two numbers between 00 and 99 from the table in par. 2.7 to select the code length starting from the most significant digit. Number 00 indicates variable code length. Number 99 indicates same code length as the first code read.
Configuration - 2.15
Page 26
DL910 SERIES
DATALOGIC
PLESSEY Disables the code
GcCgCmCcCjGjCjGjCcCgJcGgJcCjGcGjJcCcG AF0
1. Enable the code by selecting one of the check digit selections.
no check digit control
GcCgCmCcCjGjCjGjCcCgJgGcJcGjCcGjJcCcG AF1 check digit control and transmission
GcCgCmCcCjGjCjGjCcGgJgCcGgCmCcGjJcCcG AF2 check digit control without transmission
GcCgCmCcCjGjCjGjCcGgCcJgCcCmGgGjJcCcG AF3
2. Read two numbers between 00 and 99 from the table in par. 2.7 to select the code length starting from the most significant digit. Number 00 indicates variable code length. Number 99 indicates same code length as the first code read.
2.16 - Configuration
Page 27
DATALOGIC
DL910 SERIES
CODE 11 Disables the code
GcCgCmCcCjGjGcCjCjCgJcGgJcGcCjGjJcCcG AG0
1. Enable the code by selecting one of the check digit selections.
no check digit control
GcCgCmCcCjGjGcCjCjCgJgGcJcMcCcGjJcCcG AG1 control with 1 check digit transmission
GcCgCmCcCjGjGcCjCjGgJgCcCcCgGmGjJcCcG AG2 control without 1 check digit transmission
GcCgCmCcCjGjGcCjCjGgCcJgCgCmGcGjJcCcG AG3 control with 2 check digit transmission
GcCgCmCcCjGjGcCjCjGgCgJcCcGgCmGjJcCcG AG4 control without 2 check digit transmission
GcCgCmCcCjGjGcCjCjGcJgCgCgGmCcGjJcCcG AG5
2. Read two numbers between 00 and 99 from the table in par. 2.7 to select the code length starting from the most significant digit. Number 00 indicates variable code length. Number 99 indicates same code length as the first code read.
Configuration - 2.17