Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 5

DL910 Series Instruction Manual, pages 10 to 18

Pages 10 to 18 of 42

The original document is the PDF (503 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic DL910

Page 10

DL910 SERIES

DATALOGIC

1.5 STATUS INDICATORS The reader has three status indicators: two LEDs and a beeper. •

The red LED indicates the laser beam On state.

•

The green LED indicates a good read.

•

The beeper has two tones to indicate different operating conditions according to the following tables:

POWER ON Tone

Meaning

LLLL correct loading of parameters.

LHLH incorrect loading of parameters, reading or writing error in the non volatile memory

Tone

Meaning

HHHH correct ENTRY Configuration mode.

L valid read of a command

LL correct batch sequence

LLL reading error of a command

CONFIGURATION or

EXIT from

DATA ENTRY Tone

Meaning

H correct code read in normal mode

HH correct code read but FIFO memory full where :

H = high tone

1.4 - General features

L = low tone

Page 11

DATALOGIC

DL910 SERIES

2. CONFIGURATION 2.1 CONFIGURATION COMMANDS The configuration commands allow all the reader operating parameters to be set. The configuration selected can be saved in the non volatile memory and maintained when the reader is off. The commands in this manual can be used on all reader models; other commands relative to specific models are found in the relative Operator’s Manual Supplements. The commands are represented in barcode form and divided into two groups:

•

ENTRY/EDIT/EXIT CONFIGURATION Par. 2.4

•

PARAMETER SELECTION (accessible only after reading the "Entry"code). Family A Bar Code Selection Par. 2.5.

Family B Reading Parameters Par. 2.6

2.2 HOW TO CONFIGURE THE READER The reader can be configured using 3 different methods: 2.2.1 Barcode Menu Configuration (method using this Manual) 1.

Read the "Entry" menu command. The reader emits 4 high tones indicating entry into the configuration environment.

2.

Read the parameter selection commands corresponding to the desired configuration options.

3.

Repeat point 2 for all the families to modify (including those in the Operator’s Manual Supplement for your particular model).

4.

Read an "Exit" command ("Exit and save" or "End of modifications"). The reader emits 4 high tones indicating return to data entry mode.

Configuration - 2.1

Page 12

DL910 SERIES

DATALOGIC

NOTE An error in command reading is signalled by different tones, see par. 1.5 "Status Indicators". After such an error, the reader waits for a correct character sequence or a BACKSPACE command (see Par 2.4). 2.2.2 Automatic Configuration With this method the user must print one or more labels (following the syntax for normal menu configuration) that contain all the desired options. The code selected for this printing must be CODE 128 with "START B" type beginning. This rapid configuration method excludes all error risks and allows passing immediately from one configuration to another in the case of frequent application changes.

2.2.3 Copy Configuration A configured reader (source) is used to copy its configuration to a non-configured reader (destination) by connecting the two units to a copy cable and reading the correct copy configuration code. This method is suggested when configuring numerous units in the same way. The operating details are given in the Operator’s Manual Supplement relative to the interface type together with eventual operating compatibility between different software releases.

2.3 DEFAULT CONFIGURATION Each reader has a resident "default" configuration. The default options are indicated by an '*' in the parameter selection families and can be enabled by reading the "Default" label. Default configuration is normally used during the initial operating test phase of the reader. Users are advised to select the operating parameters (codes in particular) according to the application, even if the default configuration appears correct. Reading the "Default" label will cancel the actual configuration and return to the factory default.

2.2 - Configuration

Page 13

DATALOGIC

DL910 SERIES

DEFAULT PARAMETER VALUES Family A Bar Code Selection •

EAN8/EAN13/UPC A/UPC E

• STANDARD CODE 39 : no check digit control • INTERLEAVED 2/5 : no check digit control, variable length code • NORMAL 2/5 (5 bars) : no check digit control, variable length code •

STANDARD CODABAR : no start/stop equality control, start/stop transmission unchanged

Family B Reading Parameters Selection •

BEEPER INTENSITY = high

•

BEEPER TONE = tone 1

•

SOUND EMISSION = after decoding

•

DECODING SAFETY = one read

Configuration - 2.3

Page 14

DL910 SERIES

DATALOGIC

2.4 ENTRY/EDIT/EXIT CONFIGURATION ENTRY COMMAND "Entry" allows to enter the configuration environment from the normal data entry mode. Code $+

GcCgCmCgCjGgGjCgCgJcGgCgGjJcCcG EDIT COMMANDS "Backspace" cancels an incomplete configuration sequence without exiting the configuration environment, the previous parameter value remains valid. Code $%

GcCgCmCgCjGgCjCgGgCcJgGgGjJcCcG "Cancel all" cancels all modifications performed after "Entry" without exiting the configuration environment. You can then continue modifications. Code $/

GcCgCmCgCjGgCcJgGgCjCjGcGjJcCcG "Default" allows to cancel the actual configuration of the non volatile memory and reprogram with the default values. Once the command is performed the reader returns to data entry mode. Code $*

GcCgCmCgCjGgGgCjCgJgCcGgGjJcCcG NOTE The restore default configuration is also relative to the features of the output interface. If this does not comply with the operating required, the correct interface parameters must be selected immediately (see the specifications relative to the model used).

2.4 - Configuration

Page 15

DATALOGIC

DL910 SERIES

EXIT COMMANDS "Exit and save" allows to return to data entry mode from the configuration environment and save the modifications in the non volatile memory. Code $-

GcCgCmCgCjGgCgGcJgGcGjGcGjJcCcG or

"End of modifications" allows to pass from the configuration environment to data entry mode WITHOUT saving the modifications in the non volatile memory. Modifications will be lost at power off. Code $)

GcCgCmCgCjGgGgCgCjJcGcJcGjJcCcG After exiting the configuration environment with the "End of modifications" command, the following commands allow permanent storage :

Read the "Entry" command, then : "Save" allows the temporary configuration to be saved in the non volatile memory. It then returns to data entry mode. Code $(

GcCgCmCgCjGgCjGgCgGcJgCgGjJcCcG "Restore" allows the temporary configuration to be cancelled and recalls the previously saved configuration in the non volatile memory. It then returns to data entry mode. Code $.

GcCgCmCgCjGgCgGgJcCcCjGjGjJcCcG

Configuration - 2.5

Page 16

DL910 SERIES

2.5

DATALOGIC

FAMILY "A" BAR CODE SELECTION

The reader simultaneously discriminates up to five different bar codes. The same code type can be selected more times with different options (the number of characters for example). Each selected code type can be cancelled by its respective disable label. The following selection cancel all codes types:

Cancels all the codes

GcCgCmCcCjGjJcGjCcCgJcGgCcMcCjGjJcCcG AZ0

To increase the efficiency and safety of the system, only select codes effectively used; moreover when possible select the code length and enable check digit controls.

EAN/UPC FAMILY Disables the family

GcCgCmCcCjGjCcCjGjCgJcGgCcJcGjGjJcCcG AA0

EAN8/EAN13/ UPC A/UPC E(*)

GcCgCmCcCjGjCcCjGjCgJgGcJcJcGcGjJcCcG AA1

EAN8/EAN13

GcCgCmCcCjGjCcCjGjGgCcJgJcCcGjGjJcCcG AA3

UPC A/UPC E

GcCgCmCcCjGjCcCjGjGgCgJcJcGcCjGjJcCcG AA4

EAN8/EAN13/ UPC A/UPC E with ADD ON

GcCgCmCcCjGjCcCjGjGcJgCgJcMcCcGjJcCcG AA5

(*) Default 2.6 - Configuration

Page 17

DATALOGIC

DL910 SERIES

EAN/UPC FAMILY EAN8/EAN13 with ADD ON

GcCgCmCcCjGjCcCjGjGgJcCgCcCgGmGjJcCcG AA6

UPC A/UPC E with ADD ON

GcCgCmCcCjGjCcCjGjJcGcJcCgCmGcGjJcCcG AA7

EAN/UPC with and without ADD ON

GcCgCmCcCjGjCcCjGjJcCgGgCcGgCmGjJcCcG AA8

UPC E CODE OPTIONS Check digit transmission disabled

GcCgCmCcCjGjCcCjGjJgCcGgCgJcGgCcCjGjGjJcCcG AA90 enabled

GcCgCmCcCjGjCcCjGjJgCcGgCgJgGcCjGcCjGjJcCcG AA91

Code expansion disabled

GcCgCmCcCjGjCcCjGjCcCjGjCgJcGgJcGcCjGjJcCcG AAA0 enabled

GcCgCmCcCjGjCcCjGjCcCjGjCgJgGcGgCmCcGjJcCcG AAA1

Configuration - 2.7

Page 18

DL910 SERIES

DATALOGIC

CODE 39 FAMILY Disables the family

GcCgCmCcCjGjCjCcGjCgJcGgCjJcGcGjJcCcG AB0

STANDARD CODE 39 Enable the code by selecting one of the check digit selections.

no check digit control (*)

GcCgCmCcCjGjCjCcGjCgJgGcCgJgGcCcJgGgGjJcCcG AB11 check digit control and transmission

GcCgCmCcCjGjCjCcGjCgJgGcGgJgCcGgCcJgGjJcCcG AB12 check digit control without transmission

GcCgCmCcCjGjCjCcGjCgJgGcGgCcJgJcGcJcGjJcCcG AB13

FULL ASCII CODE 39 Enable the code by selecting one of the check digit selections.

no check digit control

GcCgCmCcCjGjCjCcGjGgJgCcCgJgGcGgJgCcGjJcCcG AB21 check digit control and transmission

GcCgCmCcCjGjCjCcGjGgJgCcGgJgCcGgJcCgGjJcCcG AB22 check digit control without transmission

GcCgCmCcCjGjCjCcGjGgJgCcGgCcJgJgCgGcGjJcCcG AB23

(*) Default

2.8 - Configuration