Page 86

1 DATALOGIC MEMOR™

4

4.9

DATALOGIC CONFIGURATION UTILITY

Datalogic Configuration Utility (DCU) is a Datalogic Windows-based utility tool allowing the uploading, modifying and downloading of the configuration of a Datalogic device. Configuration settings include Scanner, Control Panel, and Datalogic Desktop Utility (DDU). The DCU installer is downloadable from the Datalogic website (http://www.datalogic.com/eng/support-services/automatic-datacapture/downloads/software-utilities-sw-2.html). DCU functions in both direct (with an ActiveSync connection) and indirect (with Wavelink Avalanche™) modes. In direct mode, connect a device through ActiveSync and then click on the Get from Device icon to receive the device’s current configuration. Once loaded, the Configuration Tree (on the left side of the window) is used to navigate the device’s configuration. The right side of the window is a work area where the values of different parameters may be set for each branch of the configuration tree. Click on the parameter group branch to open it and inspect the parameters you wish to modify. After altering the device’s configuration, the new configuration can be sent to the terminal by clicking on the Send to Device icon. Reference the Wavelink Avalanche™ documentation on the Wavelink website (www.wavelink.com/Datalogic-device-downloads) for a description of indirect mode for DCU, which will allow you to update the configuration of multiple devices simultaneously over Wi-Fi.

78

Page 87

USE AND FUNCTIONING

4

4.10 DATALOGIC DESKTOP UTILITY ®

Datalogic Desktop Utility (DDU) allows administrators to configure Windows CE and Embedded Handheld devices to control individual user access. This includes the ability to:

• • • •

Prevent users from changing your device OS settings. Define keys to access specific functionality/programs. Use Application Selector to replace desktop with a selection of authorized applications Internet Explorer access restriction, configuration and customized recovery mechanisms.

To open DDU for the first time, tap Start > Settings > Control Panel > or Start > Programs > Device tools > and then double tap the icon for “Datalogic Desktop Utility”.

79

Page 88

1 DATALOGIC MEMOR™

4 These options are available from all screens: COMMAND

DESCRIPTION

OK

Tap OK to apply the settings and modifications you have made in the DDU tabs. OK saves every modifications.

X

Tap X to cancel the settings and modifications you have made in the DDU tabs. X cancels all modifications you have made in DDU.

80

Page 89

USE AND FUNCTIONING

4.10.1

4

Administrative Options (Admin tab)

When you open the DDU control panel, the “Admin” tab appears.

COMMAND

DESCRIPTION

Enable Datalogic Desktop

Select/tap this checkbox to activate the DDU functions such as Windows Access Restrictions and Application Selector.

Enter Password

Enter a password in the text box. This allows the user to specify a password when this utility is launched. By default the password is “1234”. A password can consist of all standard keyboard characters.

Re-Enter Password

Carefully re-enter the password in the second text box.

Set Password

Select/tap “Set Password” to enable the password. To change or remove the password, enter a new value, re-enter the new value, and select/tap “Set Password”.

Set Defaults

Select/tap “Set Defaults” to reset the default values of all the functions on all the tabs. After you select this option, you will receive a prompt to verify this selection.

81

Page 90

1 DATALOGIC MEMOR™

4

Setting a Password To set a password: 1.

Enter a password in the field. This allows the user to specify a password when this utility is launched. By default the password is “1234”.

Be sure to record the Password for future reference. NOTE

2. 3. 4.

Re-enter the password in the second field. Select/tap “Set Password” to enable the password. Select/tap “OK” to close the “Set Password Confirmation” dialog.

NOTE

You must select/tap “Set Password” prior to exiting DDU in order to store and activate your new password. It is not necessary to select “Enable Datalogic Desktop”.

If you select/tap “Set Defaults” it will remove all custom settings and restore all the factory default settings, except a previously set password. CAUTION

Changing a Password To change to a new password: 1. 2. 3.

82

Enter a new value in the “Enter Password field”. Re-enter the new value in the “Re-enter Password” field. Select/tap “Set Password”.

Page 91

USE AND FUNCTIONING

4

Removing a Password To remove a password: 1. 2.

Enter blanks in both “Password” fields. Select/tap “Set Password”.

Password Request Dialog Box Once the password is set, the next time you open the “Datalogic Desktop Utility”, the DDU Password dialog box opens. This dialog box will only open if a password was defined.

1.

Type in your password using either the keypad on the unit, or using the stylus on the soft input panel (SIP). If you enter an incorrect password, the system will prompt you to input the correct one.

2.

Select/tap “OK” to verify the password. Or tap “X” to cancel.

83

Page 92

1 DATALOGIC MEMOR™

4

4.10.2

Setting Hot Keys

You can use Hot Keys (HKeys) Tab to associate specific keys, such as <F1>-<F10>, with specific applications. You can also create a new Hot Key combinations. Select the HKeys tab to access these options. For example, you could set <F2> to launch a sample application like: \Windows\pword.exe.

COMMAND

DESCRIPTION

Hot Key

This pull-down list displays the available function keys to define. Select the desired one from the list.

New

Select/tap to specify a new Hot Key, not on the Hot Key list. This opens a new dialog, shown in Figure 4.

Delete

Tap to delete the selected Hot Key. You can only delete the Hot Keys you have added. You cannot delete <F1> -<F10>. This pull-down list displays the available functions. Select either Application or Action.

Associated Function Application

84

Displays path to the selected application.

Page 93

USE AND FUNCTIONING

Browse

Arguments

Action

4

Select/tap to browse for application files. You can associate an executable program with the specified Hot Key. Type the command-line arguments that are needed for the specified application. This option is only available when Application is selected in the Associated Function pull-down list. Specify an action to associate with a Hot Key. This list includes: SIP, toggle Taskbar, Datalogic Config Admin, and Application Switcher. This option is only available when Action is selected in the Associated Function pulldown list.

The <F6> is the key initially assigned to DDU Admin. If you wish to assign this key to a different function, you must first select an unassigned Hot Key and assign it to the Action - DDU Admin. You can then go back and reassign the FKey to something else.

Datalogic device 19-key models Numeric F1-F10 Alpha keys Side/top triggers Hot Keys Available

85

Page 94

1 DATALOGIC MEMOR™

4

Adding a new Hot Key When you select ‘New’ on the HKeys tab, this opens the Add New Hotkey dialog box. To define a new Hot Key, complete the following steps: 1. 2. 3.

Enter the key combination to define a new Hot Key in the Enter Key textbox. The Note displays important information indicating Hot Keys that should not be used. Select/tap OK to save the New Hot Key. If you select/tap X, the key will not be saved.

COMMAND DESCRIPTION Enter Key

Enter the desired key combination in this text box to define a Hot Key.

OK

Select/tap OK to add the specified Hot Key.

X

Select/tap X to cancel the specified Hot Key.

Make sure you do not attempt to add a Hot Key that is already defined. NOTE

86

Page 95

USE AND FUNCTIONING

4

It is possible for the keyboard wedge to activate assigned Hot Keys using alphanumeric characters. Barcodes containing characters associated with assigned Hot Keys will trigger the action or application assigned to that Hot Key. CAUTION

87