Page 76

4

1 DATALOGIC MEMOR™

You can also select Encrypt or Authenticate from the Bluetooth® control panel to apply or modify those settings. 1.

To require Authentication, check the checkbox, then tap OK.

2.

If required, the Authentication Request dialog will then open, requesting that you enter a PIN. Use the Input Panel or the keyboard to type the PIN.

3.

Tap OK to complete.

The dialog will also appear when an Authentication request is received from another device.

68

Page 77

USE AND FUNCTIONING

4

Once you have set up a pairing, you can view the settings by double-tapping its name from the Connections tab. Tap the arrow to change the Virtual Port, or Delete to remove the device pairing. Tap Sync to initiate a Sync (available only if the service is an ActiveSync connection).

69

Page 78

4

1 DATALOGIC MEMOR™

Using your device to connect to the Datalogic Memor Before turning on Bluetooth®, ensure that the two devices are within close range and that both Bluetooth-enabled devices are discoverable. 1.

From the control panel main window, double tap the Bluetooth Manager icon to open the Bluetooth Manager control panel.

2.

Tap Settings. The Settings tab allows you to enable or disable the Bluetooth® radio and specify settings for Incoming Connections.

70

Page 79

USE AND FUNCTIONING

4

3.

Select or clear the “Enable Bluetooth Radio” check box. If you’re going to be attaching a serial device (i.e. a scanner) to the Datalogic Memor, use the Port control to select a virtual COM port to use for the connection.

5.

Tap ‘Find Me’ if you want to make the Datalogic Memor discoverable to other Bluetooth® devices for 60 seconds, allowing them to set up a connection.

By default, Bluetooth® is turned off. If you turn it on, and then turn off your device, Bluetooth® also turns off. When you turn on your device again, Bluetooth® turns on automatically. NOTE

71

Page 80

1 DATALOGIC MEMOR™

4

4.6.3

FTP Server Setup

The Datalogic Memor Windows CE Operating System includes a sample File Transfer Protocol (FTP) server. FTP is used for copying files to and from remote computer systems over a network using TCP/IP. You can establish a connection to your Datalogic Memor using its FTP Server through the following interfaces: WLAN using the 802.11 abg radio Proceed as follows: 1.

Create a registry file (extension .reg) to setup and enable FTP Server communication. A simple example file for anonymous logon is given below: REGEDIT4 [HKEY_LOCAL_MACHINE\Comm\FTPD] "DefaultDir"="\\" "AllowAnonymousUpload"=dword:00000001 "UseAuthentication"=dword:00000000 "BaseDir"="\\" "IsEnabled"=dword:00000001 "LogSize"=dword:00001000 "DebugOutputMask"=dword:00000017 "DebugOutputChannels"=dword:00000002 "IdleTimeout"=dword:0000012c "AllowAnonymous"=dword:00000001 "AllowAnonymousVroots"=dword:00000001 ®

2.

Copy this file to the Datalogic Memor using ActiveSync .

3.

Launch the .reg file from the Datalogic Memor.

4.

Perform a warm boot on the Datalogic Memor.

5.

From the PC > Explorer address bar (or running an FTP Client from the PC), enter the Datalogic Memor IP address.

NOTE

72

For more information on FTP Client/Server connections refer to the following web page: http://msdn2.microsoft.com/enus/library/aa922316.aspx.

Page 81

USE AND FUNCTIONING

4.7

4

BACKUP DIRECTORY FILE MANAGEMENT

All of the Windows CE 5.0 system files reside in RAM (volatile memory) except for the Backup directory, which resides in FLASH (non-volatile memory). Therefore the contents of the Backup directory are persistent even if the mobile computer is rebooted or the battery pack is changed. You can save your more important files that you don't want to lose due to mobile computer re-boot, in the Backup directory or create a sub-directory within Backup. Even though the Windows Directory resides in RAM, it often contains files or subdirectories created by the user or by installation programs that you don't want to lose at re-boot. To keep these files persistent it is necessary to copy them to the directory \Backup\Windows. This directory doesn't exist originally (only Backup exists), and therefore it must be created. At the next cold boot, before activating the shell, Windows CE 5.0 will copy the contents including all sub-directories of \Backup\Windows to \Windows. Likewise, to maintain files that must be run at Windows CE 5.0 startup, (i.e. .exe, .lnk, .vb, .htm, etc.), it is necessary to copy them to the directory \Backup\Startup. This directory does not exist originally (only Backup exists), and therefore it must be created. The application programs will be run after any type of re-boot (both software and cold boot). As an alternative to the Safe Setup function, it is possible to copy the .cab files to the directory \Backup\Cabfiles (the Cabfiles sub-directory doesn't exists originally and must therefore be created) and perform a mobile computer cold boot to have the application installed. Once these files are copied to the directory \Backup\Cabfiles, the application will be run after each re-boot. From the second cold boot on, a message may be displayed such as "<application name> is already installed. Re-install?". This message blocks the boot process. Press the [Enter] key to continue the system initialization. Even if the entire Windows Mobile file system reside in FLASH (non-volatile memory), the mechanism described above is supported also on Windows Mobile for backward compatibility.

73

Page 82

1 DATALOGIC MEMOR™

4

4.8

DATALOGIC FIRMWARE UTILITY

The Datalogic devices are equipped with a field upgradeable firmware mechanism. Firmware updates are available on the Datalogic website: http://www.datalogic.com/eng/support-services/automatic-datacapture/downloads/software-utilities-sw-2.html. After you have downloaded the desired update, there are several ways you can update the firmware on your device. −

Use Wavelink Avalanche™ if you have multiple Datalogic devices to update. For more information refer to the dedicated section of the Wavelink website: http://www.wavelink.com/Datalogic-device-downloads.

−

If Wavelink Avalanche™ is not available or you have only a few Datalogic devices to update, use the Datalogic Firmware Utility (DFU), described below, to install or update the firmware using an ActiveSync connection.

The following sections provide procedures for the retrieval and installation of the most current firmware image onto a Datalogic device.

4.8.1

Retrieving a Firmware Image Update

The following instructions use Internet Explorer to retrieve the most current firmware image. 1.

Launch Internet Explorer on your PC and navigate to the Datalogic website.

2.

Navigate to the Downloads section of the website.

3.

Using the device selection fields, select the file you want to download, then click Save to begin copying the files to your local machine (or local network location).

74

Page 83

USE AND FUNCTIONING

4.8.2

4

Installing DFU on the Host PC

Datalogic Firmware Utility (DFU) provides administrators with a field upgrade mechanism. You must have Microsoft® ActiveSync (for Windows XP devices) or Windows Mobile® Device Center (for Windows 7 and Vista devices) already loaded and running on the host PC to use DFU. Refer to par. 4.7.1 for more information about Windows Mobile® Device Center.

Prior to installing, you must remove any previous versions of DFU installed on the host PC. NOTE

To install the Datalogic Firmware Utility, complete the following steps on the PC: 1.

Go to the Datalogic website and download the most current version of the Datalogic Firmware Utility. Unzip the file, then double-click to run DFU_Setup. exe.

2.

Click OK to continue once you have removed previous versions of DFU.

3.

The Welcome to DFU Setup Program screen opens.

4.

−

Please exit all Windows applications before running this installer.

−

Click Next to continue the Setup.

Follow the onscreen instructions to complete the installation.

75

Page 84

1 DATALOGIC MEMOR™

4

4.8.3

Updating the Firmware

After copying the firmware image to the host PC (see par. 4.10.1) and installing DFU (see par. 4.8.2), you can upgrade the firmware on your Datalogic device.

The following steps require that you have already established an ActiveSync or Windows Mobile Device Center connection between the host computer and the Datalogic device. NOTE

1.

Go to Start > Programs > Datalogic > DFU > Datalogic Firmware Utility.

2.

Verify that ActiveSync is selected by clicking Communications > WMDC/ ActiveSync. Click browse (...) and navigate to the location where you saved the firmware file for your terminal.

3.

4.

Select the current *.out file and click Open.

5.

Click Update.

6.

DFU will compare the selected firmware image with the firmware already loaded on the device; if the image is compatible with the connected device, DFU will proceed to update the firmware image on your device. After the firmware of your device has been updated, DFU will automatically perform a warm reset of the device.

76

Page 85

USE AND FUNCTIONING

4

77