Page 58
KYMAN™
3
The Scan Parameters are common to all scanner modules and allow control of the scanning device (i.e. beeper control, LED control, laser timeout, etc.). Each Data Capture screen window corresponds to a branch of the tree, and the name of the current branch is displayed at the bottom of each screen window.
Data Capture Configuration Window
The screen format shows two columns where the left column indicates branches or parameters. Branches have three dots in the right column (...). You can navigate through the tree structure using the stylus or keyboard arrows directly on the item field or from the menu. Parameters have their corresponding current values in the right column. You can edit parameter values using the stylus or keyboard arrows directly on the item field or from the menu. To change a value for example, select the line of the value to be changed, choose Edit from the Parameter Menu then choose a new value from the values listed in the box (see following figures).
40
Page 59
USE AND FUNCTIONING
3
Selecting Data Capture Setup Parameters
Alternatively using the stylus, you can tap once directly on the value on the right column; continue tapping until the desired value is reached. To activate a new configuration select the File ->Save Menu to send the new configuration to the barcode decoding software and save the new configuration. This will save the configuration to non-volatile memory preventing loss at the next system reset.
41
Page 60
3
KYMAN™
Reader Parameters The barcode reading parameters and values are dependent upon the type of scanner module mounted in your mobile computer. For a detailed list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD.
Scan Parameters The Scan Parameters are common to all scanner modules and allow control of the scanning device. The Scan parameters are described as follows: ScanTimeout: the maximum time, in milliseconds, during which the scanner remains on without decoding any barcode. BeepType: if set to dual tone, the good read beep is a sequence of high and low pitch sounds. If set to monotone, the beep is a single pitch sound. BeepDuration: the time interval, in milliseconds, during which the beeper will sound when the scanner reads a code. To disable the beeper, set this value to 0. BeepFrequency: determines the frequency in Hertz of the beeper. GoodReadSound: is the filename of a .wav file played when the scanner reads a code. LedDuration: the length of the good-read led pulse, in milliseconds. LedPulses: the number of times the good-read led pulse is emitted when the scanner reads a code. GreenSpotDuration: the length of the green spot pulse, in milliseconds ContinuousMode: disables the effect of the ScanTimeout parameter. KeyboardEmulation: if enabled all scanned data are transformed into keyboard events and can therefore be displayed and saved to a file as if input from the PDA keyboard. If set to “Yes (Clipboard)”, it copies the scanned data to the system clipboard. SoftTrigger: when enabled, the laser can be turned on/off by the application software. ScanAlwaysOn: enables the scanner for barcode reading independently from the application software. If set to “Disabled after read”, it disables the reading after a reading attempt. In case the scan button is accidentally pressed, this selection prevents the driver from decoding new data while the application is still elaborating previous data.
42
Page 61
USE AND FUNCTIONING
3
NotPrintableChar: if set to “Remove”, all not printable characters included in the scanned data are deleted and the final barcode will include only printable characters. ScanButton: enables/disables the scan button. If the scan button is disabled, the reader can be triggered under software control.
Default Settings The following tables contain the default values for the major barcode setup parameters, according to the type of scan engine mounted on the mobile computer. For a complete list of parameters and of their configuration procedures, please refer to the SDK Help file on the CD. SCAN PARAMETERS ScanTimeout BeepType BeepDuration BeepFrequency GoodReadSound LedDuration LedPulses GreenSpot Duration ContinuousMode KeyboardEmulation SoftTrigger ScanAlwaysOn NotPrintableChar ScanButton
Laser Models (XXX-1XX, XXX-4XX) 5000 Dual tone 20 2000 Beep.wav 200 mS 1 1000 Disabled Enabled Enabled Disabled Leave Enabled
Imager Models (XXX-7XX)
Laser Extra Long Range Models (XXX-6XX)
Not available Dual tone 20 2000 Beep.wav 200 mS 1 1000 Disabled Enabled Enabled Disabled Leave Enabled
5000 Dual tone 20 2000 Beep.wav 200 mS 1 1000 Disabled Enabled Enabled Disabled Leave Enabled
43
Page 62
KYMAN™
3 BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS
Laser Models (XXX-1XX, XXX-4XX)
UPC A UPC E EAN 8 EAN 13 UPC E1 EAN Bookland UPC/EAN/JAN Code 39 Code 39 Full ASCII Code 32 Code 39 Trioptic 2/5: Interleaved 2/5: Industrial 2/5: Matrix Code 128 EAN 128 ISBT 128 Codabar RSS
Enabled Enabled Enabled Enabled
*
Imager Models (XXX-7XX)
Enabled Enabled Enabled Enabled Disabled Disabled
*
Enabled Enabled Disabled
Enabled Disabled Disabled Enabled Disabled Disabled Enabled Enabled
Enabled
Enabled
Enabled Disabled
Laser Extra Long Range Models (XXX-6XX)
Enabled Disabled Disabled Disabled Enabled Disabled
Enabled Disabled
Enabled Enabled Disabled Disabled
In the Imager models these codes may only be enabled or disabled as a group by the UPC/EAN/JAN family selection (see a few lines below in the same table).
BARCODE SYMBOLOGY SPECIFIC READER PARAMETERS MSI Plessey Code 93 Code 11 PDF - 417 Data Matrix QR POSTNET PLANET Japan Post Australia Post KIX Code Royal Mail Code (RM4SCC) *
44
Laser Models (XXX-1XX, XXX-4XX) Enabled Disabled Disabled Disabled
Imager Models (XXX-7XX)
Laser Extra Long Range Models (XXX-6XX) Disabled
Enabled Enabled Enabled Enabled
Disabled*
These codes may be enabled individually but are disabled as a group.
Disabled
Page 63
USE AND FUNCTIONING
3.7.2
3
Capture
The Data Capture applet (Capture) enables code reading.
Data Capture Window
Data Capture can also be enabled through the Configuration applet by selecting File ->Scanner from the main menu, or by enabling the parameter Scan Always On in the Scan Parameters branch.
Enabling the Data Capture
45
Page 64
KYMAN™
3
3.8
CONTROL PANEL
From the Windows CE Desktop, double tap on the "My Device" icon and then double tap on the "Control Panel" icon to open the Windows CE control panel main window. The Control Panel can also be launched from Start ->Settings ->Control Panel. APPLET programs are displayed as icons; one icon corresponds to each APPLET.
Windows CE Control Panel
From the Windows Mobile Start menu, tap Settings. A three tab dialog opens: Personal, System, Connections. APPLET programs are displayed as icons; one icon corresponds to each APPLET.
Windows Mobile Control Panel
46
Page 65
USE AND FUNCTIONING
3.8.1
3
Buttons
The BUTTONS Applet allows assigning desired applications to be launched by one of the function keys (F1, F2, F3, F4). You can also select to wake up the terminal by the SCAN key and trigger key (for Datalogic Kyman-GUN™ only).
Windows CE Buttons Icon
Windows Mobile Buttons Icon
On a Windows Mobile unit the user is also able to assign a shortcut to a function key. The default programs/shortcut assigned to the function keys on Windows Mobile are the following: F1 : select the Left Soft Key F2 : open the Start Menu F3 : open the Today Screen F4 : select the Right Soft Key
To configure the way up/down and the rest of keys control repeats, use the Up/Down Control applet (Start -> Settings -> Personal -> Buttons -> Up/Down Control).
47
Page 66
KYMAN™
3
3.8.2
Registry
The REGISTRY ADMIN applet provides management of Windows CE/ Windows Mobile registry. From the Windows CE control panel main window, select the REGISTRY ADMIN applet by double tapping the Registry Admin icon. From the Windows Mobile Start menu, tap Settings -> System ->Registry. Select the REGISTRY ADMIN applet by tapping the Registry Admin icon. The Registry Administration Main window appears. Two functions are available: -
Save Registry allows permanently saving the Windows configuration (example: custom configuration of screen desktop background color, or network adapter configuration) to non-volatile memory (SAVE button).
-
Restore Default Registry allows restoring the initial factory default configuration (Restore Default button). After restoring the factory default configuration, you must perform a warm boot (see par. 3.5.3).
Saving the registry to non-volatile memory guarantees the persistence of the Windows configuration in case of battery pack replacement and in case of a cold boot.
Registry Administration Window
48
Page 67
USE AND FUNCTIONING
3.8.3
3
Files Admin
The FILES ADMIN applet enables control of the permanence of files in the Windows CE System Folder. Because Windows Mobile mounts the entire file system in persistent store (rather than using RAM), it provides both users and applications with a reliable storage platform even in the absence of battery power. The FILES ADMIN applet is therefore not necessary. Two functions are available on the Files Admin Main window by means of two buttons:
Files Admin Main Window
Save Session: with this button all files will be permanently saved in the \Windows directory in non-volatile memory. This function guarantees the steady maintenance of every file produced during the current working session - even of sub-directories and relevant files - with the exception of the files belonging to the FLASH image. These current working session files will be backed-up in the \Backup\Windows directory. At the next cold boot, the files previously saved in the \Backup\Windows directory will be restored to the Windows directory (see par. 3.10). Safe Setup: with this button, the installation of software programs will be saved to non-volatile memory (Backup directory). Before doing this, it will be checked that the Backup directory has enough space to save the files. If the directory space is not enough, an error message will be shown and the program will exit the Safe Setup function.
Two activating procedures are available for Safe Setup:
49