Page 48

KYMAN™

3

3.5.2

Numeric Keyboard (36-key Model)

Main Keys Function KEY

FUNCTION

It starts data capture.

They let you move forwards, backwards, upwards or downwards within text fields, scroll through a Menu list or browse among folder files.

30

Page 49

USE AND FUNCTIONING

3

After a yellow modifier key press, they let you scroll the pages up and down.

After a blue modifier key press, the blue arrows allow moving forwards or backwards within the Internet Explorer browser pages. Yellow modifier: when pressed before a standard key, it enables the function printed in yellow above the key. Blue modifier: when pressed before a standard key, it enables the function printed in blue above the key. When pressed, it toggles the alphanumeric/numeric modes. It locks and unlocks the keyboard. It opens the Start menu. It powers the Kyman™ ON or OFF. After a blue modifier key press, it allows returning to the Home page. After a blue modifier key press, it allows ending a page downloading. After a blue modifier key press, it performs a page refresh.

Once the Alpha mode has been entered, press the Alpha key again to exit this mode. NOTE

31

Page 50

KYMAN™

3

Keys from 1 to 9 share the following behavior scheme: A

A. B.

B

Function of the key when directly pressed Function of the key when in Alpha mode. When in Alpha mode press the key until the desired letter is shown. The letter is entered if you wait for a short timeout or if you press a different key.

Special Function Icons ICON

FUNCTION

It opens the file manager. It switches ON/OFF the keyboard backlight.

32

Page 51

USE AND FUNCTIONING

3.5.3

3

Resetting the Kyman™

Windows CE There are several reset methods for the Kyman™. A warm boot terminates an unresponsive application and clears the working RAM, but preserves both the file system and the registry. A cold boot forces all applications to close and clears working RAM and files not resident on the persistent flash memory. Registry is restored from persistent memory if available or returned to factory default. A Clean Boot restores the Kyman™ to factory configuration: registry and file system return to factory default. Warm Boot A warm boot closes all applications, clears the working RAM, but preserves the file system and registry. If an application "hangs" initiate a warm boot to terminate the application. To perform a warm boot, press these keys simultaneously:

Cold Boot A cold boot is a complete reset of the Kyman™ in which all applications are forcibly closed and RAM is completely cleared. Registry is restored from persistent memory if a saved copy is available (see 3.8.2) and RAM file system completely erased. You will lose any applications and data (registry too) which are not stored in persistent flash memory. A cold boot is necessary when the Windows CE operating system locks up and the warm boot command does not work. To perform a cold boot, press these keys simultaneously:

Clean Boot A clean boot is a cold boot that causes the device to be restored to factory configuration. The Kyman™ will reset to its factory configuration, clear the working RAM and initialize the file system. You will lose any applications and data stored in persistent flash memory. At the next startup the system will ask to recalibrate the touch screen.

33

Page 52

KYMAN™

3

To perform a clean boot, follow these steps: 1. 2. 3. 4. 5.

Perform a Cold Boot (see Cold Boot). Quickly release all the keys when the screen goes black. Within 1 second press and hold down the Esc and 0 keys until the left orange led starts blinking. Release the Esc and 0 keys. Enter 1 to proceed with the Clean Boot sequence. Enter 0 to cancel the Clean Boot and proceed with a Cold Boot.

Registry Flash Disk (Backup Folder) RAM File System

CAUTION

Warm Cold Boot Boot Preserved Restored from flash (if available) Preserved Preserved

Clean Boot

Clean disk

Preserved Reinitialized (factory default)

Factory default

Factory default

Before performing a reset, it is recommended to: execute a system backup to keep your more important files and applications persistent. See par. 3.10; save the registry to non-volatile memory to guarantee the persistence of the Windows configuration. See par. 3.8.2.

Windows Mobile There are several reset methods for the Kyman™. A warm boot terminates an unresponsive application and clears the working RAM, but preserves the file system. Registry are restored from persistent memory if available or returned to factory default. A cold boot forces all applications to close reinitializing completely the system. It clears the working RAM, but the file system is preserved. Registry are restored from persistent memory if available or returned to factory default. A clean boot restores the Kyman™ to a clean configuration: both the registry and the file system return to a clean status that conform to factory default, unless the user has installed an additional package. Warm Boot A warm boot closes all applications and clears the working RAM, but preserves the file system. Registry are restored from persistent memory if a saved copy is available (see Registry Applet, par. 3.8.2) or returned to factory default. If an application hangs, initiate a warm boot to terminate the application. To perform a warm boot, press and hold the following keys simultaneously:

34

Page 53

USE AND FUNCTIONING

3

Cold Boot A cold boot is a complete reset of the Kyman™ in which all applications are forcibly closed and the RAM is completely cleared. Registry is restored from persistent memory if a saved copy is available (see Registry Applet, par. 3.8.2). Applications and data stored on file system are preserved. A cold boot is necessary when the Windows Mobile operating system locks up and the warm boot command does not work. To perform a cold boot, press and hold the following keys simultaneously:

Clean Boot A clean boot is a cold boot that causes the device to be restored to a clean configuration. The Kyman™ will be reset to its factory configuration only if the user has not installed any additional package. Please note that you will lose any applications and data stored in persistent flash memory. To perform a clean boot, follow these steps:

1. 2. 3. 4. 5.

Perform a Cold Boot (see Cold Boot). Quickly release all the keys when the screen goes black. Within 1 second press and hold down the Esc and 0 keys until the left orange led starts blinking. Release the Esc and 0 keys. Enter 1 to proceed with the Clean Boot sequence. Enter 0 to cancel the Clean Boot and proceed with a Cold Boot.

Registry File System

Warm Boot Restored from flash Preserved

Cold Boot Restored flash Preserved

Clean Boot from Clean configuration (no user config) Clean Installation (no user files)

35

Page 54

KYMAN™

3

3.6 3.6.1

STATUS INDICATORS LED Status

The Kyman™ provides three different LEDs signaling the mobile computer status. LED

STATUS

General Purpose (left-side)

Green/Red

This LED is available to the application program.

Charging Status and Green constant Battery Low Warning

It is constant once the charging process has been completed.

(right side)

Red blinking

When the mobile computer is powered by the battery (not by the cradle nor by the cable), this LED blinks red to signal that the battery is running down.

Red constant

It is constant while charging.

Orange blinking

It blinks when a charging error has occurred, for example when a mobile computer without battery is connected to the external power or inserted into a powered cradle.

Green

It is constant for a configurable time to signal that a successful read has occurred.

Good Read (middle)

36

Page 55

USE AND FUNCTIONING

3.6.2

3

Taskbar

The Taskbar provides information about the time, the battery level, the keyboard function, and the decoding status. ICONS

DESCRIPTION

Time and Battery Icons

It displays the time. In Windows CE, they are representative of five different icons indicating the battery level. The icon is partially green when the power left is >20% and partially red colored when the power left is <20%. In Windows Mobile, it displays the system battery status. It indicates that the battery is charging (Windows CE). It shows the battery is charging (Windows Mobile). Keyboard Status Icons

It indicates that the blue FUNC key has been pressed and is going to affect the next key press. It indicates that the yellow FUNC key has been pressed and is going to affect the next key press. It indicates that the keyboard is in ALPHA mode. It indicates that the keyboard is in Normal mode. It indicates that the keyboard is in ALPHA mode and that the Capslock is active. It indicates that the keyboard is locked. Decoding Status Icons

It indicates that the decoder is active (green), not active (grey).

37

Page 56 read from a scan by OCR; it may hold reading errors

=> KYMAN™ * Sat irw Ae

Windows CE Taskbar

Windows Mobile Taskbars

38

Page 57

USE AND FUNCTIONING

3.7

3

DATA CAPTURE CONFIGURATION

From the Windows CE Taskbar, tap the "Decoding" icon to open a drop–down menu. Decoding can also be accessed from the Control Panel. By selecting the Info item from this drop-down menu you can access information about the Scanner and the Software; the Configure item opens the configuration applet (Data Capture Configuration Window), while Capture accesses the data capture applet (Data Capture Window), which enables code reading. The last menu item (Wedge) enables Wedge Emulation. From the Windows Mobile Start menu, tap Settings -> System -> Data Capture. The "Data Capture" icon opens the configuration applet (Data Capture Configuration Window).

Windows CE

3.7.1

Windows Mobile

Configure

The Configuration applet contains the barcode scanning configuration parameters in a directory tree structure. The available barcode parameters are divided into two groups: Reader Parameters and Scan Parameters. The Reader Parameters depend on the type of scanner module installed on the mobile computer and allow barcode configuration (i.e. enable/disable Code 39, check digit control, etc.).

39