Page 27
Chapter 4 Configuration Using Code Symbols This section describes the programming method of using configuration code symbols to program your reader. By using the Gryphon D432/D412Plus reader to read/decode these special configuration symbols, you can configure, and obtain information from its system software. When you are reading configuration code symbols, carefully aim the Gryphon D432/D412Plus 2D reader to avoid reading adjacent symbols. The configuration code symbols in this chapter are divided into logical sections according to the type of configuration required, (RS-232 configuration, Code selection, etc.). If arguments are required with a command, you can read additional code labels (typically digits) from Appendix D. USA Driver License Parsing is a feature not covered in this manual. For more information, reference the “USA Driver License Parsing Quick Reference Guide”, available on the Datalogic website at www.scanning.datalogic.com.
To configure your reader: 1. Read the Enter Configuration code ONCE, available on top of each page. 2. Modify the desired parameters in one or more sections by reading the parameter code and selecting the value from the Hex/Numeric table (see Appendix D) or by following the given procedures. 3. Read the Exit and Save Configuration code ONCE, available on top of each page. Example for step 3 To set the maximum length of characters in a Code 39 barcode symbol that the reader will decode to 32: • first read the Maximum Length symbol for Code 39 on page 61 • then read the symbol for the digit "3" and lastly the symbol for the digit "2" in Appendix D.
Product Reference Guide
25
Page 28
Configuration Using Code Symbols
Default Settings Configuration Field
Default Setting
RS-232 Communication Baud Rate
115200
Parity, Data Bits, Stop Bits
No parity; 8 Data bits; 1 Stop bit
Handshake
None
ACK/NACK Protocol
None
FIFO
Enabled
Intercharacter Delay
0
Intercode Delay
0
RX Timeout
10 seconds
Serial Trigger Lock
Disabled
Serial Trigger Lock Disable Character
NUL
Serial Trigger Lock Enable Character
NUL
USB COM Emulation Handshake
None
ACK/NACK Protocol
None
FIFO
Enabled
Intercharacter Delay
0
Intercode Delay
0
RX Timeout
10 seconds
USB Keyboard Emulation FIFO
Enabled
Intercharacter Delay
0
Intercode Delay
0
*Keyboard Nationality
USA
*Keyboard Speed
Normal
WEDGE-Communication *Keyboard Nationality
USA
CapsLock
OFF
CapsLock Auto-Recognition
ON
NumLock
OFF
Intercharacter Delay
0
Intercode Delay
0
IBM 46xx Interface DEFAULT SETTINGS protocol= Port 5B 1520, format = IBM Standard Format, ignore = Fake Scanner Configuration IBM USB Interface DEFAULT SETTINGS device usage, ignore = Fake Scanner Configuration
Handheld
* The default values of these parameters are set when reading the interface selection.
26
Gryphon™ D432/D412Plus
Page 29
Default Settings Configuration Field
Default Setting
Data Format-Symbology Independent Parameters Code Identifier
Disabled
Custom Code Identifier
Disabled
Code Length
Disabled
*Header
No headers
*Terminator
CR and LF terminators for RS-232, USB BULK, USB COM, USB Generic HID ENTER terminator for Wedge, USB Kbd
Data Format-Symbology Dependent Parameters Symbology Specific Format
Select All
Header Symbology
No headers
Terminator Symbology
No terminators
Symbology Character Substitution
No character to substitute
Symbology Character Deletion
No character to delete
Data Format-Concatenation Concatenation
Disabled
Define Concatenation
2 EAN/UPC codes concatenated
Set First Concatenated Code Length
000 = any length
Set Second Concatenated Code Length
000 = any length
Set Third Concatenated Code Length
000 = any length
Set Fourth Concatenated Code Length
000 = any length
Concatenation with Intercode Delay
Disabled
Concatenation Timeout
10 seconds
Concatenation Failure Transmission
Tx codes causing failure
Transmission after Timeout
No code transmission
Concatenation Result Code ID
No code Identifier
Advanced Formatting Format enable/disable
Disabled
Camera Control Exposure Mode
Automatic, based on entire image
Power Save Illumination System Power
ON
Code Selection Issue Identical Codes
Enabled
EAN/UPC Selection
Enabled
Add-On
Disabled
UPCE Expansion
Disabled
Code 39 Selection
Enabled - no check digit
Code 39 Full ASCII
Disabled
Code Length Check
Disabled
Product Reference Guide
27
Page 30
Configuration Using Code Symbols Configuration Field
Default Setting
Minimum Length
001
Maximum Length
255
Start/Stop Character
Disabled
Code 32 Selection
Disabled
Interleaved 2 of 5 Selection
Disabled
Code Length Check
Disabled
Minimum Length
014
Maximum Length
255
Codabar Selection
Disabled
Code Length Check
Disabled
Minimum Length
001
Maximum Length
255
Code 128 Code128 Selection
Enabled
Code Length Check
Disabled
Minimum Length
001
Maximum Length
255
EAN 128 Selection
Disabled
Code Length Check
Disabled
Minimum Length
001
Maximum Length
255
Code 93 Selection
Disabled
Code Length Check
Disabled
Minimum Length
001
Maximum Length
255
PDF417 Selection
Enabled
Option
Macro PDF417 Buffered Mode
Micro PDF417
Disabled
GS1 DataBar™ Family
28
GS1 DataBar Expanded
Enabled
GS1 DataBar Limited
Enabled
GS1 DataBar Omnidirectional
Enabled
GS1 DataBar Expanded Stacked
Enabled
GS1 DataBar Stacked
Enabled
Gryphon™ D432/D412Plus
Page 31
Default Settings Configuration Field
Default Setting
Data Matrix Selection
Enabled - normal & inverted
Rectangular Style
Enabled
Minimum Code Length
0001
Maximum Code Length
3600
QR Selection
Enabled
Micro QR Selection
Disabled
Postal Codes Selection
Disabled
Australian Table Selection
N Table
IMB Selection
Disabled
Maxicode Maxicode Mode 0
Disabled
Maxicode Mode 1
Disabled
Maxicode Mode 2
Disabled
Maxicode Mode 3
Disabled
Maxicode Mode 4
Disabled
Maxicode Mode 5
Disabled
Maxicode Mode 6
Disabled
Aztec Selection
Disabled
Composite Codes Selection
Disabled
Discard Linear Part
Enabled
Reading Parameters Trigger Mode
Trigger level
Trigger Type
Normal trigger
Flash ON
2 sec
Flash OFF
2 sec
Beeper Tone
Tone 1
Beeper Volume
High volume
Beeper Duration
50 ms
Reads per Cycle
One read per cycle
Aiming System Delay
Disabled
Good Read Spot
Disabled
Scan Timeout
5 sec
User Defined Beeper Tone
Tone 1
User Defined Beeper Volume
High Volume
Product Reference Guide
29
Page 32
Configuration Using Code Symbols Configuration Field
Default Setting
User Defined Beeper Duration
100 ms
Codes per Scan
One code per scan
Central Code Transmission
Disabled
Order by Code Length
Disabled
Order by Code Symbology
Disabled
Autoscan Mode
Disabled
Autoscan Aiming System
Enabled
Autoscan Hardware Trigger
Enabled
Autoscan Illumination System
Disabled
Safety Time
500 ms (if Autoscan mode or Software trigger type is selected and the Multiple Reads per Cycle option is enabled.
Stand AutoScan Mode
Normal
Image Formatting Image Preset 1, 2, 3, 4 Image Format
JPEG format
Set JPEG Quality Factor
50
Brightness
0%
Contrast
0%
Color Depth
256 gray levels
Changing Default Settings Once the reader is set up, you can change the default parameters to meet your application needs. Refer to the preceding paragraphs for initial configuration in order to set the default values and select the interface for your application. In this manual the configuration parameters are divided into logical groups, making it easy to find the desired function base in its reference group. The RS-232, USB, WEDGE groups are for Standard Interface parameter configuration. The following parameter groups are common to all interface applications: • DATA FORMAT parameters regard the messages sent to the Host system. • POWER SAVE parameters manage overall current consumption in the device. • CODE SELECTION parameters allow configuration of a personalized mix of codes, code families and their options. • READING PARAMETERS control various operating modes and indicators status functioning. • CAPTURE IMAGE parameters activate image capturing. • ADVANCED CAPTURE IMAGE parameters define options of the image to capture. • ADVANCED DATA FORMAT parameters allow advanced formatting of messages towards the Host. Once the configuration is modified, it is possible to save it as a Custom Default Configuration and to restore it at any time using a specific command.
30
SAVE CUSTOM DEFAULT
RESTORE CUSTOM DEFAULT
AMHKGOBOFNGNENEIEPANHOGOCK AHHPMJAMDKEOFMHMLJALEBDGIK AKCBPJCJGIIJCMCFHOOBOFKHJK AEFBJLBGMHPLMLBENPIJOBOEGK AAPHBAJICAELBENPOIFJGNJBHK AGKFBJKCGEBMMAEBJHEAKDILKK DDDDLDLLLLDLLLLDLDLDDLDLLL
AMHKGOBOFNGNENEIEPANHOGOCK AHHPMBIMDKEOFMHMLJALEHBFIK AKCBPJCJGIIJCMCFGPNNEKBJPK AEFBJLBGMHPLMMGACKPFEHFFGK AAPHBAJIDDAMENHAAFBFAFPDBK AHKFBMLLKCCKGKAEDCDMCKPKIK DDDDLDLLLLDLLLLDDDLDDLDLLL
Gryphon™ D432/D412Plus
Page 33
\
Enter Reader Configuration
Exit and Save Reader Configuration
AMHKGMHOFNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJALFCAFIK AKCBPJCJGIIJCMCEGOODCCEDJK AEFBJLBGMHPLNPGLABJHFIAEGK AAPHBAJICCBGBIAFNLNLLAINDK AFLFBPPCOIHKILNFFOCKOLJILK DLDDLDDLDDLLLLLDDDLDDLDLLL
AMHKCMHOFNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJALFEGFIK AKCBPJCJGIIJCMCEGLJKNEBJLK AEFBJLBGMHPLMIFPAFAIIBNHGK AAPHBAJIDGDHOJDKAICECIENBK AGLFBOMJMHLIGBPCKIGAGOEKLK DDLDLDDLLLDLLLLDDDDDDLDLDL
RS-232 INTERFACE
RS-232 INTERFACE BAUD RATE 1200 baud
2400 baud
AODOBPHMHNGNENEIEPANHOGOCK AHHPMBIMDKEOFMHMLJALEAEHIK AKCBPJCJGIIJCMCFGKKJKOJDJK AEFBJLBGMHPLMKBDIAOJAOCFGK AAPHBAJJDEBGGOGPJMMKGENDBK AGKFAMOCFGFEOEMPKONGEDGLJK DDDLLLLDDLLLLLLDLDLDDLDLDL
AODOBPHMHNGNENEIEPANHOGOCK AHHPMBAMDKEOFMHMLJAKFFEFIK AKCBPJCJGIIJCMCEHMOCCMGBNK AEFBJLBGMHPKNKGHFCHBECLHGK AAPHBAJICAFOGLINMDNLINCNFK AFKFAPIBAPGEIJIHHJLGAGJLIK DDDLLLLDDLLLLLLDDDLDDLDLDL
4800 baud
9600 baud
AODOBPHMHNGNENEIEPANHOGOCK AHHPEJIMDKEOFMHMLJALFBDEIK AKCBPJCJGIIJCMCEGJKDEHBFLK AEFBJLBGMHPLMOFOMLCDNGPGGK AAPHBAJICAGAPEPJLLEPPMPNFK AGLFAOPPDHDGCAJLOLBOAEPJJK DDLLLLLDDLLLLLLDDDDDDLDLLL
AODOBPHMHNGNENEIEPANHOGOCK AHHPEJAMDKEOFMHMLJAKEEDGIK AKCBPJCJGIIJCMCFHPOIMFOHPK AEFBJLBGMHPKNOCKBJLLJKGEGK AAPHBAJJDECIPBBLOEFOBFADBK AFLFANJMGOAGENNDDMHOEBAJIK DDLLLLLDDLLLLLLDLDDDDLDLLL
14400 baud
19200 baud
AODOBPHMHNGNENEIEPANHOGOCK AHHPEBIMDKEOFMHMLJAKECBFIK AKCBPJCJGIIJCMCFGONEGKFJJK AEFBJLBGMHPKNJFOOMMHDMNFGK AAPHBAJJCHGPKILEAJBCHNGBHK AELFAIIFKIDAOHJGJJACMIHIKK DDLLLLLDDLLLLLLDDDDDDLDLLL
AODOBPHMHNGNENEIEPANHOGOCK AHHPEBAMDKEOFMHMLJALFHBHIK AKCBPJCJGIIJCMCEHIJPOIKLNK AEFBJLBGMHPLMJCKDOFPHAEHGK AAPHBAJIDDCHKNFGFGADJEJPDK AHLFALOGPBAAIKNOEOGCINIILK DDLLLLLDDLLLLLLDLDDDDLDLLL
38400 baud
57600 baud
AODOBPGMHNGNENEIEPANHOGOCK AHHPMJIMDKEOFMHMLJAKEGAGIK AKCBPJCJGIIJCMCEHJMNMHBHNK AEFBJLBGMHPLMJEFHPOOLLEGGK AAPHBAJJDEELFPOLNABGHGBJBK AHKFAPKHDDAKGGJMLDOCGOJIJK DLLLLLLDLLDLLLLDDLDDDLDLLL
AODOBPGMHNGNENEIEPANHOGOCK AHHPMJAMDKEOFMHMLJALFDAEIK AKCBPJCJGIIJCMCFGPIGEFOFJK AEFBJLBGMHPKNJDBKNHGPHNEGK AAPHBAJICAADFKAJIPAHJPOHFK AEKFAMMEGKDKALNEGEICCLGIIK DLLLLLLDLLDLLLLDLLDDDLDLLL
115200 baud AODOBPGMHNGNENEIEPANHOGOCK AHHPMBIMDKEOFMHMLJALFFCHIK AKCBPJCJGIIJCMCFHOLKOKFLPK AEFBJLBGMHPKNOEFFIAKFBGFGK AAPHBAJIDDEEADKGGCELPHIFDK AFKFAJNNKMAMKBJBMBPOKCBJKK DLLLLLLDLLDLLLLDDLDDDLDLLL
Product Reference Guide
31
Page 34
Enter Reader Configuration
Exit and Save Reader Configuration
AMHKGMHOFNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJALFCAFIK AKCBPJCJGIIJCMCEGOODCCEDJK AEFBJLBGMHPLNPGLABJHFIAEGK AAPHBAJICCBGBIAFNLNLLAINDK AFLFBPPCOIHKILNFFOCKOLJILK DLDDLDDLDDLLLLLDDDLDDLDLLL
AMHKCMHOFNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJALFEGFIK AKCBPJCJGIIJCMCEGLJKNEBJLK AEFBJLBGMHPLMIFPAFAIIBNHGK AAPHBAJIDGDHOJDKAICECIENBK AGLFBOMJMHLIGBPCKIGAGOEKLK DDLDLDDLLLDLLLLDDDDDDLDLDL
RS-232 INTERFACE
PARITY None
Odd
AODOCKHMHNGNENEIEPANHOGOCK AHHPMJAMDKEOFMHMLJAKEHDEIK AKCBPJCJGIIJCMCFHKNICLPJPK AEFBJLBGMHPKMKCBGHIFAIHGGK AAPHBAJICBECCPIFDALHLEPDBK AHKFAKNLOFKOENMPPBAEMFGLKK DLLLLLLDDDLLLLLDDLLDDLDLDL
AODOCKHMHNGNENEIEPANHOGOCK AHHPMBIMDKEOFMHMLJAKEBBHIK AKCBPJCJGIIJCMCFGLOEIEEHJK AEFBJLBGMHPKMNFFJCPJKOMHGK AAPHBAJIDCAFHGCKNNPLNMJBHK AGKFAPMCCDJIOHIKFEHIEMBKIK DLLLLLLDDDLLLLLDLLLDDLDLDL
Even AODOCKHMHNGNENEIEPANHOGOCK AHHPMBAMDKEOFMHMLJALFEBFIK AKCBPJCJGIIJCMCEHNKPAGLFNK AEFBJLBGMHPLNNCBEAGBOCFFGK AAPHBAJJCGENHDMIICOKDFGPDK AFKFAMKBHKKIIKMCIDBIAJOKJK DLLLLLLDDDLLLLLDDLLDDLDLDL
DATA BITS 7 Bits
8 Bits
AODKGOHMHNGNENEIEPANHOGOCK AHHPMJAMDKEOFMHMLJALFGHFIK AKCBPJCJGIIJCMCEHMNLNAOLPK AEFBJLBGMHPLNNCDILOHNKLGGK AAPHBAJICBAGNCCMNKDBECODFK AFKFAMPJFJLIGJIGMPLCONMJKK DLLLLLLDDDDLLLLDDLLDDLDLLL
AODKGOHMHNGNENEIEPANHOGOCK AHHPMBIMDKEOFMHMLJALFAFGIK AKCBPJCJGIIJCMCEGNOHHPFFJK AEFBJLBGMHPLNKFHHOJLHMAHGK AAPHBAJIDCEBILIDDHHNCKIBDK AEKFAJOAJPIOMDMDGKMOGELIIK DLLLLLLDDDDLLLLDLLLDDLDLLL
STOP BITS 1 Bit
2 Bits
AODKGOHMFNGNENEIEPANHOGOCK AHHPMJAMDKEOFMHMLJALEDHFIK AKCBPJCJGIIJCMCFGPJNAPDJLK AEFBJLBGMHPLNPBLKBBJJBCEGK AAPHBAJIDBEGBLCBDNBOCGFFDK AEKFAMNDDBAAALDFGLGGCILLKK DDLLLLLDLLDLLLLDLLDDDLDLLL
AODKGOHMFNGNENEIEPANHOGOCK AHHPMBIMDKEOFMHMLJALEFFGIK AKCBPJCJGIIJCMCFHOKBKAIHNK AEFBJLBGMHPLNIGPFEGFDHJFGK AAPHBAJICCABECIONAFCEODHFK AFKFAJMKPHDGKBHAMOBKKBMKIK DDLLLLLDLLDLLLLDDLDDDLDLLL
ACK/NACK PROTOCOL Disabled
Enabled
AODKGKHMFNGNENEIEPANHOGOCK AHHPMJAMDKEOFMHMLJAKEBBHIK AKCBPJCJGIIJCMCEGIPKHBNLJK AEFBJLBGMHPLNPGMAAHBOHIFGK AAPHBAJJDEDMBEFCELBBMOPPDK AFLFAIPIECJKKHKLNFCCILOKJK DDDLLLLDDLLLLLLDDDDDDLDLDL
AODKGKHMFNGNENEIEPANHOGOCK AHHPMBIMDKEOFMHMLJAKEHDEIK AKCBPJCJGIIJCMCEHJMGNOGFPK AEFBJLBGMHPLNIBIPFANEBDEGK AAPHBAJJCHHLENPNKGFNKGJNFK AELFANOBIEKMANOOHAFOACJLLK DDDLLLLDDLLLLLLDLDDDDLDLDL
See "ACK/NACK Protocol" on page 113 for details.
32
Gryphon™ D432/D412Plus
Page 35
\
Enter Reader Configuration
Exit and Save Reader Configuration
AMHKGMHOFNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJALFCAFIK AKCBPJCJGIIJCMCEGOODCCEDJK AEFBJLBGMHPLNPGLABJHFIAEGK AAPHBAJICCBGBIAFNLNLLAINDK AFLFBPPCOIHKILNFFOCKOLJILK DLDDLDDLDDLLLLLDDDLDDLDLLL
AMHKCMHOFNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJALFEGFIK AKCBPJCJGIIJCMCEGLJKNEBJLK AEFBJLBGMHPLMIFPAFAIIBNHGK AAPHBAJIDGDHOJDKAICECIENBK AGLFBOMJMHLIGBPCKIGAGOEKLK DDLDLDDLLLDLLLLDDDDDDLDLDL
RS-232 INTERFACE
RX TIMEOUT RX Timeout
Read a number in the range 00-99, where:
AODKBPHMFNGNENEIEPANHOGOCK AHPNIJAMDKEOFMHMLJALFFCFIK AKCBPJCJGIIJCMCEGJNHKMOHPK AEFBJLBGMHPLMOFHAGONLNCEGK AAPHBAJJDFAAALCKIJIBHMDDFK AFKFAMNLMCOCGLMJDCDIENPLKK DLLLLLLDLLDLLLLDLDDDDLDLLL
00= disabled 01-99= timeout from 1 to 99 secs
See "RX Timeout" on page 113 for details.
SERIAL TRIGGER LOCK Disabled
Enabled
AODPCOHMHNGNENEIEPANHOGOCK AHHPMJAMDKEOFMHMLJALEHCEIK AKCBPJCJGIIJCMCEGPPNPFEFLK AEFBJLBGMHPLNIHIDCFKGICHGK AAPHBAJICFBGACOMKGOJHNKLFK AEKFANPJPMFEGKBGFLJOMIIIIK DLLLDLLDLDDLLLLDDDDDDLDLLL
AODPCOHMHNGNENEIEPANHOGOCK AHHPMBIMDKEOFMHMLJALEBAHIK AKCBPJCJGIIJCMCEHOMBFKPLNK AEFBJLBGMHPLNPAMMHCGMOJGGK AAPHBAJIDGFBFLEDELKFBFMJDK AFKFAIOADKGCMAFDPOOCEBPJKK DLLLDLLDLDDLLLLDLDDDDLDLLL
Serial Trigger Lock Characters AODPBPHMFNGNENEIEPANHOGOCK AHPNIJAMDKEOFMHMLJALECBEIK AKCBPJCJGIIJCMCEHPIIHPBDJK AEFBJLBGMHPLNMDILLMPNGGGGK AAPHBAJJCFDBCKNFCGKGNLLLHK AHKFAMOAEIMMICHOFAFOONGIIK DDDLDLLDLDLLLLLDLLDDDLDLDL
Read two characters for Serial Trigger Lock/ Unlock. The 2 characters must be read sequentially as Hex values from the Hex/Numeric table. Valid values are in the range 00-FF
HANDSHAKE
Product Reference Guide
None
XON/XOFF
AODKGKHMHNGNENEIEPANHOGOCK AHHPMJAMDKEOFMHMLJAKFEBHIK AKCBPJCJGIIJCMCFHLLMKOAJNK AEFBJLBGMHPLNNFECKIPKMBHGK AAPHBAJJCEHMNNFPKMDOKKEJFK AELFAINCCKCCMFBIHBPGEOJIJK DLDLLLLDLDLLLLLDLDLDDLDLDL
AODKGKHMHNGNENEIEPANHOGOCK AHHPMBIMDKEOFMHMLJAKFCDEIK AKCBPJCJGIIJCMCFGKIAABLHLK AEFBJLBGMHPLNKCANPPDAKKGGK AAPHBAJJDHDLIEPAEBHCMCCLDK AFLFANMLOMBEGPFNNEIKMHOJLK DLDLLLLDLDLLLLLDDDLDDLDLDL
RTS/CTS
RTS Always On
AODKGKHMHNGNENEIEPANHOGOCK AHHPMBAMDKEOFMHMLJALEHDGIK AKCBPJCJGIIJCMCEHMMLIDEFPK AEFBJLBGMHPKMKFEANGLEGDEGK AAPHBAJICDHDIBBCBOGDCLNFHK AGLFAOKILFCEACBFADOKICBJKK DLDLLLLDLDLLLLLDLDLDDLDLDL
AODKGKHMHNGNENEIEPANHOGOCK AHHPEJIMDKEOFMHMLJAKEDEHIK AKCBPJCJGIIJCMCEGJIKOIDBJK AEFBJLBGMHPLNOGNJEDJNCHFGK AAPHBAJICDENBOGGGGPHFKAFHK AFKFAPNGINHGKLAJJBECIAHLLK DLLLLLLDLDLLLLLDLDDDDLDLLL
33
Page 36
Enter Reader Configuration
Exit and Save Reader Configuration
AMHKGMHOFNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJALFCAFIK AKCBPJCJGIIJCMCEGOODCCEDJK AEFBJLBGMHPLNPGLABJHFIAEGK AAPHBAJICCBGBIAFNLNLLAINDK AFLFBPPCOIHKILNFFOCKOLJILK DLDDLDDLDDLLLLLDDDLDDLDLLL
AMHKCMHOFNGNENEIEPANHOGOCK AHPNIBAMDKEOFMHMLJALFEGFIK AKCBPJCJGIIJCMCEGLJKNEBJLK AEFBJLBGMHPLMIFPAFAIIBNHGK AAPHBAJIDGDHOJDKAICECIENBK AGLFBOMJMHLIGBPCKIGAGOEKLK DDLDLDDLLLDLLLLDDDDDDLDLDL
RS-232 INTERFACE
FIFO Disabled
Enabled
AODKGKFOHNGNENEIEPANHOGOCK AHHPMJAMDKEOFMHMLJALEHEEIK AKCBPJCJGIIJCMCFHKPBPDILLK AEFBJLBGMHPLMKFOFBKAHDNHGK AAPHBAJJDDHLEHJBMCFNGJDNHK AGKFAILCKNMOEJCKPGAMODCKIK DLDLLLLDLLDLLLLDLDDDDLDLLL
AODKGKFOHNGNENEIEPANHOGOCK AHHPMBIMDKEOFMHMLJALEBGHIK AKCBPJCJGIIJCMCFGLMNFMDFNK AEFBJLBGMHPLMNCKKENMNFGGGK AAPHBAJJCADMBODOCPBBABFPBK AHKFANKLGLPIODGPFDHAGKFLKK DLDLLLLDLLDLLLLDDDDDDLDLLL
INTERCHARACTER DELAY Intercharacter Delay AODKBPHMHNGNENEIEPANHOGOCK AHPNIJAMDKEOFMHMLJALEACFIK AKCBPJCJGIIJCMCFHKJBHDDFLK AEFBJLBGMHPLMMGPCMBDPGLGGK AAPHBAJJCFEAMCCHGOKOBIIFDK AEKFAMPBKKFKAJHKJGOMIIIJKK DDLLLLLDDDDLLLLDDDLDDLDLLL
00
= disabled
01-99 = delay from 1 to 99 msec
INTERCODE DELAY Intercode Delay AODKBPFOHNGNENEIEPANHOGOCK AHPNIJAMDKEOFMHMLJAKFDHGIK AKCBPJCJGIIJCMCFHLNMCOLHNK AEFBJLBGMHPLNLGFFHDMCJHGGK AAPHBAJJDCEHFIOJAAMNNLPBBK AGLFAMJBCNLGIFEIBBBGCFDLLK DDLLLLLDDLLLLLLDDDDDDLDLDL
34
00
= disabled
01-99 = delay from 1 to 99 sec
Gryphon™ D432/D412Plus