Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 4 of 20

Gryphon D432/D412Plus Barcode Reader Product Reference Guide: Initial Setup

Pages 21 to 26 of 160, from Gryphon D432/D412Plus Barcode Reader Product Reference Guide

The original document is the PDF (3.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Datalogic D432

Page 21

Chapter 3 Initial Setup This procedure allows setting up the reader to operate with the default settings. Whenever you need to change the default values refer to "Changing Default Settings" on page 30.

RS-232 Interface Selection The Gryphon D432/D412Plus reader requires the RS-232 interface cable and the AC/DC power adapter to be connected. To install and configure your reader with the RS-232 interface, follow these instructions: 1. Make all system connections as shown:

2. Read the restore default parameter code below: Restore Default AMHKGPAOFNGNENEIEPANHOGOCK AHHPMBAMDKEOFMHMLJALECHGIK AKCBPJCJGIIJCMCFGPLCMMMNLK AEFBJLBGMHPKMOGNKKNDPDMGGK AAPHBAJIDGHPOJKEFPNCEACBHK AFKFBKNGLGMOMELLGOPCMJFKIK DDDDLDLLLDDLLLLDDDLDDLDLDL

3. Read the RS-232 interface selection code: RS-232 AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJAKFEHFKK AMGNPJCJGIIJCMCEGJMHNDOLLK AIFBJLBGMHPLNKECPCGMBBIBOK AAPHBAJJDAAGMGKDDAOHBGGLHK AEKFBONJCDDIECLFJIJKMCHLIK DLDDLDLDLLDLLLLDLLDDDLDLLL

4. Power up your PC. RS-232 is the default interface set at the factory.

Product Reference Guide

19

Page 22

Initial Setup

Wedge Interface Selection The Gryphon D432Plus reader requires the Wedge interface cable. To install and configure your reader with the Wedge interface, follow these instructions: 1. Connect the cable to the Gryphon D432Plus reader and to the PC as shown:

2. Power up your PC. 3. Read the restore default parameter code below: Restore Default AMHKGPAOFNGNENEIEPANHOGOCK AHHPMBAMDKEOFMHMLJALECHGIK AKCBPJCJGIIJCMCFGPLCMMMNLK AEFBJLBGMHPKMOGNKKNDPDMGGK AAPHBAJIDGHPOJKEFPNCEACBHK AFKFBKNGLGMOMELLGOPCMJFKIK DDDDLDLLLDDLLLLDDDLDDLDLDL

4. Read the Wedge IBM AT interface selection code: Wedge – IBM AT AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJALFAEHKK AEONPJCJGIIJCMCEHPLLHLPPJK AIFBJLBGMHPLNPDFHGDGFIBDOK AAPHBAJJCGCOPJDIMBCEANODDK AFKFBPPJPJCAALOIKIECIPIKLK DDLDLDLDDLDLLLLDDDDDDLDLDL

USB Interface Selection The Gryphon D432/D412Plus reader requires the USB interface cable and, if required, the AC/DC power adapter to be connected. The USB interface is compatible with: Windows 98 (and later)

IBM POS for Windows

Mac OS 8.0 (and later)

4690 Operating System

Start-Up

As with all USB devices, upon connection, the Host performs several checks by communicating with the Gryphon D432/D412Plus. During this phase the green LED on the Gryphon D432/D412Plus reader blinks and normal operations are suspended. Two basic conditions must be met before Gryphon D432/D412Plus is ready to read codes: the correct USB driver must be loaded and sufficient power must be supplied to the reader. For all systems, the correct USB driver for the default USB-KBD interface or the USB Generic HID interface is included in the Host Operating System and will either be loaded automatically

20

Gryphon™ D432/D412Plus

Page 23

USB Interface Selection or will be suggested by the O.S. and should therefore be selected from the dialog box (the first time only). If the Host supplies sufficient power to the reader, the start-up phase ends correctly, the green LED stops blinking and the reader emits the beep OK signal. If the Host does not supply sufficient power to the reader, a dialog box will appear on the Host and the reader will be blocked (green LED continues blinking). In this case, disconnect the USB cable at the Host (green LED stops blinking), connect and power-up an external supply to USB cable then reconnect the USB cable to the Host and close the dialog box. The reader emits the beep OK signal. You can now read codes. At this point you can read the USB interface configuration code according to your application. Load drivers from the O.S. (if requested). When configuring the USB-COM interface or DLBulkUSB interface, the relevant files and drivers must be installed and can be downloaded from the web site http://www.scanning.datalogic.com. The reader is ready. FIRST START-UP Green LED b lin ks

Connect Gryphon™ D432/D412Plus to Host

1.

Load drivers (if reques ted)

Green LED o ff

Disc onnec t reader at H os t

Does a dialog box appear warning that Bus power is not sufficient?

YES

C onnec t external power supply to cable and power up

BEEP OK

NO Green LED o ff - BEEP OK Select desired USB interface code (USB-KBD is default)

Reconnect reader c able to Hos t and close dialog box

2.

Load drivers (if reques ted)

R ead test codes . Reader is READY

Successive start-ups will automatically recognize the previously loaded drivers. If external power is used, verify that external power is already supplied. SUCCESSIVE START-UPS Connect Gryphon™ D432/D412Plus to Host

Gr een LED blinks

Dis connect reader at Hos t

YES

Connect ex ternal power supply to cable and power up

Does a dialog box appear warning that Bus power is not sufficient? NO G reen LED o ff - BEEP O K

BEEP O K

Product Reference Guide

Rec onnect reader cable to Host and close dialog box

Read tes t c odes. Reader is READY

21

Page 24

Initial Setup To install and configure your reader with one of the USB interfaces, see the "First Start-up" diagram above and follow these instructions. 1. Make all the Gryphon D432/D412Plus reader connections as shown:

USB Connections

2. Power up your PC. 3. Read the desired USB interface selection code:

22

USB-COM EMULATION

USB-KBD EMULATION

AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJALEAGEKK AMONPJCJGIIJCMCFHLPMOOKNBK AIFBJLBGMHPLMLAMDPIKFBLBOK AAPHBAJICHGNBKOPLNBGLPAHFK AHKFBNPHFKLEAOHGLPKOGDJLLK DLDDLDLDDLDLLLLDDDLDDLDLDL

AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJAKEDBEKK AMGNPJCJGIIJCMCFHMNJLBJPHK AIFBJLBGMHPKNMBGMJOJEHHAOK AAPHBAJICDHCJBCNKPCNNJNFHK AFLFBMPJIKPAMFFBBHKCCKNIKK DLLDLDLDLLDLLLLDDDDDDLDLLL

USB BULK

USB Generic HID

AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJAKFDDHKK AEGNPJCJGIIJCMCEHIJOCEMNPK AIFBJLBGMHPKMICPIAFFEONCOK AAPHBAJJCCDBHCPKNDBPGLDBBK AHLFBOPHCJGEMAMPAAEOMGMJKK DDDDLDLDLLDLLLLDDDLDDLDLLL

AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJALEHCGKK AEONPJCJGIIJCMCFGKKFBJILFK AIFBJLBGMHPKNJGBENLDAOOCOK AAPHBAJIDFFKKOLGFOOOMCFNDK AELFBNNJFAOIIMAMCHHKGHCJJK DDDDLDLDDLDLLLLDLLDDDLDLDL

Gryphon™ D432/D412Plus

Page 25

USB Interface Selection

IBM PORT 9B/PORT 5B/IBM USB *The IBM PORT 9B and IBM PORT 5B are only for Gryphon D412 + models.

1. Make all the Gryphon D432/D412Plus reader connections as shown:

2. Read the desired IBM interface selection codes: IBM PORT 9B

IBM PORT 5B

AMHKHMFPHMGNEJEIEPANHOGOCK AGPFONFCPKEOFMHMLJALEABEKK AHCPLNCJGIIJCMCEHNPGDOEBCK AAFBJLBGMHPKMPHKHIHFLPANKK AAPHBAJICBFFGJNMEFIBBCHBBK AGKFBILMPCDMDEFEFKKMEDKLLK DLDDLDLDLDLLLLLDDLDDDLDLDL

AMHKHMFPHMGNEJEIEPANHOGOCK AGPFONEDPKEOFMHMLJAKEFFHKK AHCPLNCJGIIJCMCEHMLILIKJGK AAFBJLBGMHPLNIFNPNEPPFMNKK AAPHBAJJCCAFHGAJDDKJMHFFFK AELFBINACDBGBBGHDPBAIMCLLK DDDDLDLDDDLLLLLDLLLDDLDLDL

Gryphon D412 + models only

IBM USB AMHKHMFOHNGNENEIEPANHOGOCK AGOEPJAMDKEOFMHMLJAKECFEKK AMONPJCJGIIJCMCFGMMHLFIFJK AIFBJLBGMHPKMLBHKCCKPLJDOK AAPHBAJIDDFDDLPAENDNINCJHK AHKFBNJDHPIEOENLMJAAEBAIJK DDDDLDLDLLLLLLLDDLLDDLDLLL

Product Reference Guide

23

Page 26

Initial Setup

NOTES

24

Gryphon™ D432/D412Plus