Page 21
Chapter 3 Initial Setup This procedure allows setting up the reader to operate with the default settings. Whenever you need to change the default values refer to "Changing Default Settings" on page 30.
RS-232 Interface Selection The Gryphon D432/D412Plus reader requires the RS-232 interface cable and the AC/DC power adapter to be connected. To install and configure your reader with the RS-232 interface, follow these instructions: 1. Make all system connections as shown:
2. Read the restore default parameter code below: Restore Default AMHKGPAOFNGNENEIEPANHOGOCK AHHPMBAMDKEOFMHMLJALECHGIK AKCBPJCJGIIJCMCFGPLCMMMNLK AEFBJLBGMHPKMOGNKKNDPDMGGK AAPHBAJIDGHPOJKEFPNCEACBHK AFKFBKNGLGMOMELLGOPCMJFKIK DDDDLDLLLDDLLLLDDDLDDLDLDL
3. Read the RS-232 interface selection code: RS-232 AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJAKFEHFKK AMGNPJCJGIIJCMCEGJMHNDOLLK AIFBJLBGMHPLNKECPCGMBBIBOK AAPHBAJJDAAGMGKDDAOHBGGLHK AEKFBONJCDDIECLFJIJKMCHLIK DLDDLDLDLLDLLLLDLLDDDLDLLL
4. Power up your PC. RS-232 is the default interface set at the factory.
Product Reference Guide
19
Page 22
Initial Setup
Wedge Interface Selection The Gryphon D432Plus reader requires the Wedge interface cable. To install and configure your reader with the Wedge interface, follow these instructions: 1. Connect the cable to the Gryphon D432Plus reader and to the PC as shown:
2. Power up your PC. 3. Read the restore default parameter code below: Restore Default AMHKGPAOFNGNENEIEPANHOGOCK AHHPMBAMDKEOFMHMLJALECHGIK AKCBPJCJGIIJCMCFGPLCMMMNLK AEFBJLBGMHPKMOGNKKNDPDMGGK AAPHBAJIDGHPOJKEFPNCEACBHK AFKFBKNGLGMOMELLGOPCMJFKIK DDDDLDLLLDDLLLLDDDLDDLDLDL
4. Read the Wedge IBM AT interface selection code: Wedge – IBM AT AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJALFAEHKK AEONPJCJGIIJCMCEHPLLHLPPJK AIFBJLBGMHPLNPDFHGDGFIBDOK AAPHBAJJCGCOPJDIMBCEANODDK AFKFBPPJPJCAALOIKIECIPIKLK DDLDLDLDDLDLLLLDDDDDDLDLDL
USB Interface Selection The Gryphon D432/D412Plus reader requires the USB interface cable and, if required, the AC/DC power adapter to be connected. The USB interface is compatible with: Windows 98 (and later)
IBM POS for Windows
Mac OS 8.0 (and later)
4690 Operating System
Start-Up
As with all USB devices, upon connection, the Host performs several checks by communicating with the Gryphon D432/D412Plus. During this phase the green LED on the Gryphon D432/D412Plus reader blinks and normal operations are suspended. Two basic conditions must be met before Gryphon D432/D412Plus is ready to read codes: the correct USB driver must be loaded and sufficient power must be supplied to the reader. For all systems, the correct USB driver for the default USB-KBD interface or the USB Generic HID interface is included in the Host Operating System and will either be loaded automatically
20
Gryphon™ D432/D412Plus
Page 23
USB Interface Selection or will be suggested by the O.S. and should therefore be selected from the dialog box (the first time only). If the Host supplies sufficient power to the reader, the start-up phase ends correctly, the green LED stops blinking and the reader emits the beep OK signal. If the Host does not supply sufficient power to the reader, a dialog box will appear on the Host and the reader will be blocked (green LED continues blinking). In this case, disconnect the USB cable at the Host (green LED stops blinking), connect and power-up an external supply to USB cable then reconnect the USB cable to the Host and close the dialog box. The reader emits the beep OK signal. You can now read codes. At this point you can read the USB interface configuration code according to your application. Load drivers from the O.S. (if requested). When configuring the USB-COM interface or DLBulkUSB interface, the relevant files and drivers must be installed and can be downloaded from the web site http://www.scanning.datalogic.com. The reader is ready. FIRST START-UP Green LED b lin ks
Connect Gryphon™ D432/D412Plus to Host
1.
Load drivers (if reques ted)
Green LED o ff
Disc onnec t reader at H os t
Does a dialog box appear warning that Bus power is not sufficient?
YES
C onnec t external power supply to cable and power up
BEEP OK
NO Green LED o ff - BEEP OK Select desired USB interface code (USB-KBD is default)
Reconnect reader c able to Hos t and close dialog box
2.
Load drivers (if reques ted)
R ead test codes . Reader is READY
Successive start-ups will automatically recognize the previously loaded drivers. If external power is used, verify that external power is already supplied. SUCCESSIVE START-UPS Connect Gryphon™ D432/D412Plus to Host
Gr een LED blinks
Dis connect reader at Hos t
YES
Connect ex ternal power supply to cable and power up
Does a dialog box appear warning that Bus power is not sufficient? NO G reen LED o ff - BEEP O K
BEEP O K
Product Reference Guide
Rec onnect reader cable to Host and close dialog box
Read tes t c odes. Reader is READY
21
Page 24
Initial Setup To install and configure your reader with one of the USB interfaces, see the "First Start-up" diagram above and follow these instructions. 1. Make all the Gryphon D432/D412Plus reader connections as shown:
USB Connections
2. Power up your PC. 3. Read the desired USB interface selection code:
22
USB-COM EMULATION
USB-KBD EMULATION
AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJALEAGEKK AMONPJCJGIIJCMCFHLPMOOKNBK AIFBJLBGMHPLMLAMDPIKFBLBOK AAPHBAJICHGNBKOPLNBGLPAHFK AHKFBNPHFKLEAOHGLPKOGDJLLK DLDDLDLDDLDLLLLDDDLDDLDLDL
AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJAKEDBEKK AMGNPJCJGIIJCMCFHMNJLBJPHK AIFBJLBGMHPKNMBGMJOJEHHAOK AAPHBAJICDHCJBCNKPCNNJNFHK AFLFBMPJIKPAMFFBBHKCCKNIKK DLLDLDLDLLDLLLLDDDDDDLDLLL
USB BULK
USB Generic HID
AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJAKFDDHKK AEGNPJCJGIIJCMCEHIJOCEMNPK AIFBJLBGMHPKMICPIAFFEONCOK AAPHBAJJCCDBHCPKNDBPGLDBBK AHLFBOPHCJGEMAMPAAEOMGMJKK DDDDLDLDLLDLLLLDDDLDDLDLLL
AMHKHMFOHNGNENEIEPANHOGOCK AGPEPJAMDKEOFMHMLJALEHCGKK AEONPJCJGIIJCMCFGKKFBJILFK AIFBJLBGMHPKNJGBENLDAOOCOK AAPHBAJIDFFKKOLGFOOOMCFNDK AELFBNNJFAOIIMAMCHHKGHCJJK DDDDLDLDDLDLLLLDLLDDDLDLDL
Gryphon™ D432/D412Plus
Page 25
USB Interface Selection
IBM PORT 9B/PORT 5B/IBM USB *The IBM PORT 9B and IBM PORT 5B are only for Gryphon D412 + models.
1. Make all the Gryphon D432/D412Plus reader connections as shown:
2. Read the desired IBM interface selection codes: IBM PORT 9B
IBM PORT 5B
AMHKHMFPHMGNEJEIEPANHOGOCK AGPFONFCPKEOFMHMLJALEABEKK AHCPLNCJGIIJCMCEHNPGDOEBCK AAFBJLBGMHPKMPHKHIHFLPANKK AAPHBAJICBFFGJNMEFIBBCHBBK AGKFBILMPCDMDEFEFKKMEDKLLK DLDDLDLDLDLLLLLDDLDDDLDLDL
AMHKHMFPHMGNEJEIEPANHOGOCK AGPFONEDPKEOFMHMLJAKEFFHKK AHCPLNCJGIIJCMCEHMLILIKJGK AAFBJLBGMHPLNIFNPNEPPFMNKK AAPHBAJJCCAFHGAJDDKJMHFFFK AELFBINACDBGBBGHDPBAIMCLLK DDDDLDLDDDLLLLLDLLLDDLDLDL
Gryphon D412 + models only
IBM USB AMHKHMFOHNGNENEIEPANHOGOCK AGOEPJAMDKEOFMHMLJAKECFEKK AMONPJCJGIIJCMCFGMMHLFIFJK AIFBJLBGMHPKMLBHKCCKPLJDOK AAPHBAJIDDFDDLPAENDNINCJHK AHKFBNJDHPIEOENLMJAAEBAIJK DDDDLDLDLLLLLLLDDLLDDLDLLL
Product Reference Guide
23
Page 26
Initial Setup
NOTES
24
Gryphon™ D432/D412Plus