Page 111

TROUBLESHOOTING & MAINTENANCE

4.3

4

MAINTENANCE

You do not need to perform regular preventative maintenance on the LYNX™ reader.

Do not try to open the case, because you might damage the interior electronic components and such action voids the warranty. You can keep your reader in good operating condition by:

• periodically cleaning the reading window using water or a mild detergent solution and a soft cloth or tissue.

• watching for any damage to the housing.

CAUTION

Do not use abrasive cleaning agents on the reader's window to avoid scratches. Do not use solvents on the housing or window to avoid damage. Do not submerge the reader in water. It is not waterproof.

95

Page 112

LYNX™

5

5

TECHNICAL FEATURES LYNX™ D302 / D302 E Common Features

Electrical Features Operating Voltage Power Consumption @ 12V (Stand-by) @ 12V (Typical) @ 10V (Peak current)

10 to 30 V 200 mA 300 mA 440 mA

Communications Features Interface

RS232, Keyboard emulation AT IBM, USB

Environmental Features Operating Temperature Storage Temperature Humidity Shock resistance

0° to +40 °C (+32° to +104 °F) -20° to +70 °C (-4° to +158 °F) 0 to 95% NC IEC 68-2-32 Test ED

Mechanical Features Dimensions Weight

203 x 117.2 x 68.9 mm (7.99 x 4.61 x 2.71 inches) 265 g (9.3 oz.) without cable

Decoding Capability 1D 2D Postal Codes

Interleaved 2 of 5, Code39, MSI, Code128, EAN 128, Code93, UPC/EAN/JAN, Codabar, RSS PDF417, Micro PDF, Maxicode, DataMatrix (ECC200), QR, AZTEC POSTNET, PLANET, Japan Post, Australia Post, KIX Code, Royal Mail Code (RM4SCC)

Imaging Option Image Graphic Format

96

640 x 480 pixel format (VGA); 8 bit gray scale 320 x 240 pixel format (CIF); 8 bit gray scale JPEG BMP

Page 113

TECHNICAL FEATURES

5 LYNX™ D302

Optical Features Sensor Aiming Ambient light Focus distance Field of view Max Resolution Depth of field* 1D (linear): Code39 EAN13 2D: POSTNET PDF417 QR DataMatrix Maxicode Skew Pitch Rotation Print Contrast (Min.)

*

640 x 480 pixel element, 2D CCD Array Visible laser diode at 650 nm 0 - 100000 lux 115 mm 28.6° (H) x 21.9° (V) Linear codes – mm (mils) Datamatrix – mm (mils) 0.13 (5) 0.25 (10) X-dimension – mm (mils) 0.13 (5) 0.5 (20) 0.33 (13) X-dimension – mm (mils) 0.5 (20) 0.17 (6.6) 0.25 (10) 0.25 (10) 0.38 (15) 0.25 (10) 0.38 (15) --

DOF – cm (inches) 7.5 to 10.5 (2.95 to 4.13) 7.5 to 32.5 (2.95 to 12.8) 4.5 to 20.5 (1.77 to 8.07) DOF – cm (inches) 7.5 to 32.5 (2.95 to 12.8) 4.5 to 16.0 (1.77 to 6.3) 3.5 to 21.5 (1.37 to 8.46) 5.5 to 10.5 (2.16 to 4.13) 4.5 to 17.5 (1.77 to 6.89) 6.0 to 12.0 (2.36 to 4.72) 4.5 to 16.5 (1.77 to 6.5) 4.5 to 32.5 (1.77 to 12.8)

±40° ±35° 360° 23%

Reading distances are measured from the nose of the reader.

97

Page 114

LYNX™

5 LYNX™ D302 E

Optical Features Sensor Aiming Ambient light Focus distance Field of view Max Resolution Depth of field* 1D (linear): Code39 2D: PDF417 QR DataMatrix (4/157.4 cell) DataMatrix Skew Pitch Rotation Print Contrast (Min.)

*

98

640 x 480 pixel element, 2D CCD Array Visible laser diode at 650 nm 0 - 100000 lux 55 mm 21.8° (H) x 16.2° (V) Linear codes – mm (mils) Datamatrix – mm (mils) 0.076 (3) 0.13 (5) X-dimension – mm (mils) 0.13 (5) X-dimension – mm (mils) 0.13 (5) 0.25 (10) 0.13 (5) 0.25 (10) 0.13 (5) 0.25 (10)

DOF – cm (inches) 3.5 (1.37) to 7.0 (2.75) DOF – cm (inches) 4.0 to 7.5 (1.57 to 2.95) 4.5 to 10.0 (1.77 to 3.93) 4.5 to 6.0 (1.77 to 2.36) 3.5 to 8.5 (1.37 to 3.34) 4.5 to 6.0 (1.77 to 2.36) 3.5 to 8.5 (1.37 to 3.34)

±60° ±50° 360° 45%

Reading distances are measured from the nose of the reader.

Page 115

TECHNICAL FEATURES

5 LYNX™ D402

Electrical Features Operating Voltage Power Consumption @ 12V (Stand-by) @ 12V (Typical) @ 10V (Peak current)

10 to 30 V 182 mA 300 mA 360 mA

Communications Features Interface

RS232, Keyboard emulation AT IBM, USB

Optical Features Sensor Aiming Ambient light Focus distance Field of view Horizontal field of view at distance (d) in mm Vertical field of view at distance (d) in mm Max Resolution Depth of field* 1D (linear):

640 x 480 pixel element, 2D CMOS Array Visible laser diode at 650 nm 0 - 100000 lux LYNX™ D402 115 mm 21.8° (H) x 16.7° (V) 0.4d + 12 0.3d + 9 Linear codes - mm (mils) 0.13 (5)

Datamatrix – mm (mils) 0.17 (6.6)

X-dimension mm (mils) 0.13 (5)

Symbol size cm (in) 1.2 (0.47)

0.5 (20)

3.2 (1.26)

0.33 (13)

3.1 (1.22)

POSTNET

X-dimension mm (mils) 0.5 (20)

PDF417

0.13 (5)

Symbol size cm (in) 4.0 x 0.4 (1.57 x 0.16) 1.1 x 0.9 (0.43 x 0.35) 1.4 x 1.2 (0.55 x 0.47) 2.2 x 1.8 (0.86 x 0.71)

Code39

EAN13 2D:

0.17 (6.6) 0.25 (10)

DOF cm (in) 8.0 to 15.0 (3.15 to 5.90) 8.0 to 33.0 (3.15 to 12.99) 7.5 to 24.5 (2.95 to 9.65) DOF cm (in) 11.5 to 30.0 (4.53 to 11.81) 8.5 to 15.5 (3.35 to 6.10) 7.0 to 19.0 (2.76 to 7.48) 4.5 to 24.0 (1.77 to 9.45)

99

Page 116

LYNX™

5

Optical Features QR

0.25 (10) 0.38 (15)

DataMatrix

0.19 (7.5) 0.25 (10) 0.38 (15)

Skew Pitch Rotation Print Contrast (Min.)

0.7 x 0.7 (0.28 x 0.28) 1.1 x 1.1 (0.43 x 0.43) 0.8 x 0.8 (0.31 x0.31) 0.8 x 0.8 (0.31 x 0.31) 1.0 x 1.0 (0.39 x 0.39) ±40° ±35° 360° 23%

7.0 to 15.5 (2.76 to 6.10) 4.5 to 21.0 (1.77 to 8.27) 9.0 to 13.0 (3.54 to 5.12) 7.5 to 16.5 (2.95 to 6.50) 6.0 to 22.0 (2.36 to 8.66)

Environmental Features Operating Temperature Storage Temperature Humidity Shock resistance

0° to+ 40 °C (+32° to +104 °F) -20° to +70 °C (-4° to +158 °F) 0 to 95% NC IEC 68-2-32 Test ED

Mechanical Features Dimensions Weight

203 x 117.2 x 68.9 mm (7.99 x 4.61 x 2.71 inches) 265 g (9.3 oz.) without cable

Decoding Capability 1D 2D Postal Codes

Interleaved 2 of 5, Code39, MSI, Code128, EAN 128, Code93, UPC/EAN/JAN, Codabar, RSS;MSI PDF417, Micro PDF, Maxicode, DataMatrix (ECC200), QR, AZTEC: Codablock A; Codablock F; Codablock F EAN POSTNET, PLANET, Japan Post, Australia Post, KIX Code, Royal Mail Code (RM4SCC)

Imaging Option Image Graphic Format

*

100

640 x 480 pixel format (VGA); 8 bit gray scale 320 x 240 pixel format (CIF); 8 bit gray scale JPEG BMP

Reading distances are measured from the nose of the reader.

Page 117

PROGRAMMING FOR EXPERT USERS

A

A

PROGRAMMING FOR EXPERT USERS

This document is addressed to expert users who are familiar with software programming languages and want to define a personalized code formatting. The provided programming language allows creating either simple or complex formatting expressions by means of the basic functions connected together through the following operators: (, ), -, +. The syntax to be used to transmit the expressions to the Lynx™ is the following:

$+ELB<n>formatting expression<ETX>$where:

−

<n> is a number in the range 1-5 corresponding to the format to be defined;

−

<ETX> is the conventional character used as terminator of the command;

− the formatting expression uses ASCII characters when containing text strings. For this reason, the string must be inserted between two quotation marks. The following example shows the ASCII conversion of the "ABC" string: $+ELB1S414243T+#DS^C$-.

A.1

FUNCTION DESCRIPTION

All the functions and conventions to be used within the formatting expressions are listed below:

FUNCTION NAME FSTR FLSTR SSTR FPOS LSTR ISTR RSTR

DESCRIPTION Searches for a defined substring by its starting and ending string. Searches for a defined substring by its starting string and its length. Extracts a defined substring from the original string. Searches for a position of a defined substring within the original string. Returns a string length. Insert a substring in the original string. Substitutes a defined substring contained in the original string with a new one.

101

Page 118

LYNX™

A CONVENTIONS + #DS #F<n>

DESCRIPTION Concatenates two strings or fields. Deletes a substring or a field from the original string. Returns the string which has been decoded by the library. Returns the result of a format which has been previously defined. The <n> value is in the range 1-4.

FindStringByStarting&EndingChar (FSTR) This function has the following syntax:

FSTR<source_string, string_start, string_stop, mode>Östring This function searches for a substring having a defined starting character ("string_start") and a defined ending character ("string_stop") within the "source_string". It returns the string you searched for, or an empty one in case of failure. If searching for a substring having characters already known, the "string_start" and "string_stop" arguments must share the same value. The "mode" argument allows managing the starting character ("string_start") and the ending character ("string_stop"): 0 = include both starting and ending character 1 = include only starting character 2 = include only ending character 3 = discard both starting and ending character

FindStringByStartingChar&Len (FLSTR) This function has the following syntax:

FLSTR<source_string, string_start, len, mode>Östring This function searches for a substring having a defined starting character ("string_start") and a defined length ("len") within the "source_string". It returns the string you searched for, or an empty one in case of failure. If searching for a substring having a length already known, the "string_start" and "string_stop" arguments must share the same number. The "mode" argument allows managing the starting character ("string_start"): 0 = include starting character 1 = discard starting character

102

Page 119

PROGRAMMING FOR EXPERT USERS

A

SelectString (SSTR) This function has the following syntax:

SSTR<source_string, pos_start, pos_end>Östring It extracts a substring whose characters are between "pos_start" and "pos_end" from the "source_string". If "pos_end" is longer than the "source_string" length, no error will be generated since the exceeding characters are ignored. The first character of every string is in position 1.

FindPosition (FPOS) This function has the following syntax:

FPOS<source_string, search_string>Öposition This function searches for a defined substring within the "source_string" and returns its position. If the substring is not found, the returned value is 1.

StringLength (LSTR) This function has the following syntax:

LSTR<string>Ölength This function returns the length of the defined string.

StringConcatenation This function has the following syntax: string1 + string2Östring This function allows concatenating two different strings in order to get a single string as result.

103

Page 120

A

LYNX™

StringDiscard This function has the following syntax: string1 - string2Östring This function discards all the strings having the same value as "string2" which can be found in "string1". If no "string2" is found within "string1", the result returns "string1".

InsertString (ISTR) This function has the following syntax:

ISTR<source_string, string1, position>Östring This function inserts a new string ("string1") within the "source_string" and places it in the defined "position". If the value of the "position" argument is longer than "source_string" length, "string1" will be placed after the last character of the source string.

ReplaceString (RSTR) This function has the following syntax:

RSTR<source_string, string1, string2>Östring This function searches for "string1" within the "source_string". All the strings having the same value as "string1" within the "source_string" will be replaced by "string2". If no "string1" is found in the "source_string", the result returns the "source_string".

104