Page 91

ADVANCED DATA FORMAT

Method 2 - Manipulating the Barcode Data Method 2 allows modifying the barcode data by means of one of the following procedures: −

String insertion;

−

String deletion;

−

String substitution;

− Field deletion. Once the data has been modified, it is sent to the host computer as data of the output message. Unlike Method 1 this method does not allow associating different procedures together. This means that each format definition corresponds to a single procedure. Despite this, it possible to add a new string of characters to the beginning or ending part of the formatted barcode. The only limit is determined by the size of the internal reserved memory used to define the format.

75

Page 92

ADVANCED DATA FORMAT

STRING INSERTION To complete this procedure proceed as follows:

Define Format 1, 2, 3, 4, or 5

YES

Add String?

Add new String

NO Insert String

YES

Add new String

Add

Add String?

Add NO End Format Definition

Example Decoded code: <DATALOGICproduct> Formatting procedure: Add new string + Insert String Define New String

End String

+ 31 + 37 +

String Position

+ 31 + 32 + 33 +

Add

+ i i

Insert String k k

+

End Selection

+5 k k

Output message: <17DATA123LOGICproduct>

76

End Format

+ hDDk hDDk

+

Page 93

ADVANCED DATA FORMAT

String Insertion Procedure a)

Insert String Insert String b)

Read the Hex value from the Hex/Numeric table identifying the characters to be inserted. Valid values are in the range 00-7F.

Define String Position String Position c)

Read a number corresponding to the string position within the barcode.

End Selection End Selection d)

k k k k

EITHER

Read the code to end the field selection.

Add String

Add i i i i k k k k

OR

To add a new string of characters read the barcode and follow the procedure described on page 81;

End Format Definition

End Format Definition hDDk hDDk hDDk hDDk

Read the code to end the format definition.

77

Page 94

ADVANCED DATA FORMAT

STRING DELETION To complete this procedure proceed as follows:

Define Format 1, 2, 3, 4, or 5

Add String?

YES

Add new String

NO Delete String

Add

Delete Add new String

YES

Add String?

Add NO End Format Definition

Example Decoded code: <DATALOGICproduct> Formatting procedure: Delete First String + Delete Second String + Add New String. Delete String

+ 4C +4F +

Loop

End Selection

Define New String

End String

+ 33 + 31 +

End Format

+

Output message: <DATAGICpruct31>

78

+ 6F +64 + hDDk hDDk

Add

+ i i k k

+

Page 95

ADVANCED DATA FORMAT

String Deletion Procedure a)

Delete String Delete b)

Read the Hex value from the Hex/Numeric table identifying the string character(s) to be deleted. Valid values are in the range 00-7F.

(optional)

Select Other Strings to be Deleted

Loop c)

Read the code above and repeat the procedure from step a.

End Selection End Selection d)

EITHER

Read the code to end the selection.

Add String

Add i i i i k k k k

OR

To add a new string of characters read the barcode and follow the procedure described on page 81;

End Format Definition

End Format Definition hDDk hDDk hDDk hDDk

Read the code to end the format definition.

79

Page 96

ADVANCED DATA FORMAT

STRING SUBSTITUTION To complete this procedure proceed as follows:

Define Format 1, 2, 3, 4, or 5

Add String?

YES

Add new String

NO Substitute String YES

Add new String

Add

Add String?

Add NO End Format Definition

Example Decoded code: <DATALOGICproduct> Formatting procedure: Add new string + String substitution + Add new string. Define New String

End String

+ 34 + 33 +

Substituting String

End Selection

+ 37

Add

+ i i

Add

+ i i k k

Substitute String k k

+

Define New String

End String

Output message: <43D7T7LOGICproduct43>

80

+

+ 34 + 33 +

+

41 +

End Format

+ hDDk hDDk

Page 97

ADVANCED DATA FORMAT

String Substitution Procedure a)

Define String to be Substituted Substitute String b)

Read the Hex value from the Hex/Numeric table identifying the characters of the string to be substituted. Valid values are in the range 00-7F.

Define Substituting String Substituting String c)

Read the Hex value from the Hex/Numeric table identifying the characters of the substituting string. Valid values are in the range 00-7F.

End Selection End Selection d)

EITHER

Read the code to end the selection.

Add String

Add i i i i k k k k

OR

To add a new string of characters read the barcode and follow the procedure described on page 81;

End Format Definition

End Format Definition hDDk hDDk hDDk hDDk

Read the code to end the format definition.

81

Page 98

ADVANCED DATA FORMAT

FIELD DELETION To complete this procedure proceed as follows:

Define Format 1, 2, 3, 4, or 5

YES

Add String?

Add new String

NO Delete Field

Add

Delete YES

Add new String

Add String?

Add NO End Format Definition

Example Decoded code: <DATALOGICproduct> Formatting procedure: Delete First Field + Delete Second Field + Add New String.

+

End Selection

+

+

+

Add

+ i i k k

Output message: <DGICct51>

82

+ 41 +

+

+ 4C + 4F + 2nd Field Ending Character

2nd Field Starting Character

Loop

End Selection

+ 75 +

1st Field Ending Character

1st Field Starting Character

Delete

+ 70 + 72 +

Define New String

End String

+ 35 + 31 +

+

End Format

+ hDDk hDDk

Page 99

ADVANCED DATA FORMAT

Field Deletion Procedure a)

Delete Field Delete b)

Read the code to enable the command deleting the field.

Define Field Starting Character Field Starting Character c)

Read the Hex value from the Hex/Numeric table identifying the starting characters. Valid values are in the range 00-7F.

Define Field Ending Character Field Ending Character d)

Read the Hex value from the Hex/Numeric table identifying the ending character/s. Valid values are in the range 00-7F.

End Field Selection End Selection e)

(optional)

Read the code to end the field selection.

Select Other Fields to be Deleted

Loop

Read the following code and repeat the procedure from step b for each field to be deleted:

83

Page 100

ADVANCED DATA FORMAT f)

EITHER

Add String

Add i i i i k k k k

OR

To add a new string of characters read the barcode and follow the procedure described on page 81;

End Format Definition

End Format Definition hDDk hDDk hDDk hDDk

84

Read the code to end the format definition.